• Title/Summary/Keyword: 진단용방사선발생장치

Search Result 62, Processing Time 0.024 seconds

Quality Control of Diagnostic X-ray Equipment in Medical Field (의료분야 진단용방사선발생장치의 품질관리)

  • Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.159-164
    • /
    • 2021
  • The examination using diagnostic x-ray equipment is one of the most useful diagnostic equipment for identifying information in the human body in diagnostic radiology. For this reason, the number of examinations has recently increased a lot. Increasing the number of examinations will accelerate the aging of the device. In addition, this makes them aware of the importance of quality control for the diagnostic x-ray device. Particularly, in a diagnostic x-ray device, quality control refers to an act of always maintaining a certain level of image quality by identifying and correcting all problems that may lead to reduction of the diagnosis area in advance. Therefore, this study summarizes and reports general information about quality control in examinations using diagnostic x-ray equipment.

A Study on the Management of Exposure of Workers and Assistants Related to Diagnostic Radiation (진단용 방사선 관련 업무 종사자의 피폭관리에 관한 연구)

  • Lim, Chang-Seon
    • The Korean Society of Law and Medicine
    • /
    • v.22 no.3
    • /
    • pp.97-124
    • /
    • 2021
  • In medical institutions, there are radiation-related workers such as radiological technologists, physicians, dentists, and dental hygienists who handle diagnostic radiation generators. Also, there are work assistants, such as nurses and assistant nurses, who assist in radiation treatment or transfer patients to the radiation examination room. Radiation exposure management for radiation-related workers is carried out under the 「Medical Service Act」, but there is no legal basis for work assistants, etc. And the management of radiation exposure for diagnosis is regulated by the 「Medical Service Act」, and the management of radiation exposure by therapeutic radiation and nuclear medical examination is governed by the 「Nuclear Safety Act」. Thus, to improve the management of radiation exposure for diagnosis, the regulations on radiation exposure management for diagnosis under the 「Medical Service Act」 were compared and reviewed with those of the 「Nuclear Safety Act」. As a result, the main contents are as follows. First, it is necessary to legislate to include nurses, assistant nurses, and clinical practice students who are likely to be exposed to radiation besides radiationrelated workers as subjects of radiation exposure management for diagnosis. Second, when a radiation-related worker for diagnosis is confirmed to be pregnant, the exposure dose limit should be defined. Third, it is necessary to revise the regulations on the types of personal exposure dosimeters in the 「Rules on the Safety Management of Radiation Generators for Diagnostics」. Fourth, it seems that health examination items for radiation-related workers, radiation workers, and frequent visitors should be the same. Fifth, It is necessary to unify and regulate diagnostic radiation and all medical radiation, including therapeutic radiation and nuclear medicine, in one legal system.

Problems of the Act and Subordinate Statutes Related to the Regulation of Radiation Safety for Diagnosis (진단용 방사선 안전관리 법령의 문제점에 관한 연구)

  • Lim, Chang-Seon
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.2
    • /
    • pp.97-118
    • /
    • 2022
  • The use of diagnostic radiation in medical institutions is rapidly increasing. Accordingly, the collective effective dose is on the rise every year. Therefore, it is necessary to reduce the radiation exposure of the person undergoing the radiation examination as low as reasonably achievable. And we must establish a legal system to perform the safe management of radiation for diagnosis efficiently. In this way, I went over the problems of the Act and Subordinate Statutes regarding radiation safety management for diagnosis. As a result, the main contents are as follows. First, in the 「Medical Service Act」, there is no basis for the Safety Inspection Institute of Radiation and Radiation Exposure Measuring Institutes. And there are no provisions concerning delegation of administrative disposition. Therefore, it is necessary to secure legal justification by providing the basis for the Safety Inspection Institute of Radiation along with Radiation Exposure Measuring Institutes and the basis for administrative dispositions against these institutions in the 「Medical Service Act」. Second, the 「Rules on the Installation and Operation of Special Medical Equipment 」 should be integrated with the 「Rules on the Safety Management of Radiation Generators for Diagnostics」 to unify administrative procedures such as reporting for radiation special medical equipment for diagnosis. Third, in the case of violating the diagnostic radiation safety management standards in the 「Rules on the Safety Management of Radiation Generators for Diagnostics」, it is necessary to supplement the insufficient sanctions such as administrative disposition. Fourth, regulating diagnostic radiation and therapeutic radiation used in medical institutions with the dual legal system of the 「Medical Act」 and the 「Nuclear Safety Act」 is not efficient in the safety management of diagnostic radiation. Therefore, it is necessary to uniformly regulate diagnostic radiation and all medical radiation, including therapeutic radiation and nuclear medicine, in the 「Medical Service Act」 system.

Comparison of the Legislation Applicable to Compare the use of Diagnostic Radiation Devices (진단용 방사선발생장치 이용에 적용되는 법제의 비교)

  • Ko, Jong-Kyung;Jeon, Yeo-Ryeong;Han, Eun-Ok;Cho, Pyong-Kon;Kim, Yong-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.277-286
    • /
    • 2015
  • Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subject to the Nuclear Safety Act. Even the same radiation devices varies the legislation that is applied depending on the intended use and object. Diversified been p rovisions a re necessary compared to t he analysis o f l egal content in o rder t o prevent confusion of the legislation is a matter to be applied. It is a qualitative study that Nuclear Safety Act, Medical Service Act and Veterinarians Act administrative procedures for the introduction of the applied diagnostic radiation devices, safety inspection, human resources management, area management and the content related to administrative punishment. The Nuclear Safety Act sub-provisions, the introduction of diagnostic radiation generating devices, there are many complex and complete requirements administrative procedures on the concept of a permit. Inspection of safety associated with the use, would be subject to periodic inspection auditing characteristics over the entire field of radiation safety management. It must receive court regular education for the safety administrator and workers. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Quantitative difference of administrative punishment that is imposed when legislation violation has reached up to 10 times, over the entire field, the largest burden of radiation safety management at the time of application of the Nuclear Safety Act sub provisions. And it is applied differently depending on the purpose and the imaging target using the same diagnostic radiation devices. Depending on the use mainly under the current legal system, radiation can be lacking in fairness of the contents of the legislation for safety management, there is a risk of confusion. Alternatives such as centralized and standardization of legislation by diagnostic radiation devices use is expected to be necessary.

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.

국내 동정

  • Korea Radioisotope Association
    • 동위원소뉴스
    • /
    • no.5 s.101
    • /
    • pp.9-11
    • /
    • 2005
  • PDF

Convergence analysis of safety management for radiation workers and diagnostic radiation-generator devices of animal hospital in Korea (국내 동물병원의 진단용 방사선 발생장치 및 방사선 관계종사자 안전관리에 관한 융복합적 분석)

  • Kang, Kyoung-Mook;Suh, Tae-Young;Kim, Yong-Sang;Yun, Seon-Jong
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.55-61
    • /
    • 2020
  • The various types of radiation-generator devices have been used in animal hospitals, and the safety for radiation workers is becoming important in Korea. This study investigated and analyzed the radiation safety management for diagnostic radiation-generator devices and radiation workers of animal hospital. The number of radiation-generator devices and radiation workers of animal hospital increased from 2,138 to 2,972 and from 2,644 and 5,733 for six years. The number of general X-ray, CT, C-arm, portable and dental X-ray in 2019 were 2,204, 58, 67, 770, and 14. The number of veterinarian, veterinary nurse, veterinary assistant, and others in 2019 were 4,236, 1,080, 404, and 13. The average exposure dose of radiation workers in 2018 were 0.21mSv in surface dose, 0.18mSv in depth doses. This study is expected to be the basic data for the safety management of radiation-generating devices and radiation workers in animal hospital.