• 제목/요약/키워드: 진공관형 집열기

검색결과 36건 처리시간 0.019초

흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화 (Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray)

  • 김용;서태범;강용혁
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

진공관형 태양열 집열기의 구리-유리 직접 접합 기술 (Technique of Direct Copper to Glass Seal in an Evacuated Tube Solar Collector)

  • 김철영;임형봉;조남권;곽희열
    • 한국세라믹학회지
    • /
    • 제43권9호
    • /
    • pp.544-551
    • /
    • 2006
  • The sealing technique between a glass tube and a copper heat pipe in an evacuated tube solar collector is studied. In this study two different sealing techniques, such as flame method and furnace firing, are examined. After the sealing of a copper to a glass, the oxidation state of the copper and its bonding morphology were examined by SEM and XRD. Its oxidation was retarded by coating of borate solution on the copper, and $Cu_2O(cuprite)$ turned into CuO(tenorite) with increase in a firing temperature and firing time. Porous structure was found in the oxide layer when CuO formed. The best sealing morphology was observed when the thickness of the oxidation layer was less than $20{\mu}m$. The sealing technique performed in a furnace was promising and the satisfactory result was obtained when the sample was fired at $950^{\circ}C$ for 5 min under $N_2$ atmosphere. Annealing procedure is recommended to remove the stress left at the bonding zone.

태양열 실증 시스템의 냉방 및 급탕 일일 열성능 (Thermal performance of solar cooling and hot water for the demonstration system)

  • 이호;김상진;주홍진;곽희열
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.564-569
    • /
    • 2007
  • This study describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about 350㎡ was heated and cooled with the solar system. The system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, subsidiary tank, absorption chiller, chiller storage tank, and cooling tower. The results of the experimental study indicated that the total solar energy gain as daily performance on a sunny day (August 25, 2007) with total daily radiation of $606\;W/m^2$ was 671 kWh, the collecting efficiency of 55%. In the case of supplies to heat source more than $83^{\circ}C$, cooling time operated by solar was driven 8.8 hours, cooling energy generated by solar system was 179 kWh and the solar cooling fraction was 79.2%, and hot water supplied with surplus heat source by the solar system was 201 kWh.

  • PDF

태양열 시스템의 제어조건에 따른 난방 및 급탕 실증연구 (Demonstration study on Heating and Hot water According to Control Condition of Solar System)

  • 주홍진;곽희열;김정배;김종보
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.832-837
    • /
    • 2006
  • This study describes thermal performance of heating and cooling demonstration system using ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about $331m^2$ was heated and cooled using that system. The demonstration system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, and subsidiary tank. From January to March in 2006, demonstration test were performed with 4 control mode to find the optimum control condition for solar thermal system. After experiments and analysis, this study found that solar thermal system of control mode IV was corresponded to 78% for the hot water supply and 49% for space heating.

  • PDF

등축 유로를 가진 이중진공관형 태양열 집열기의 열성능에 관한 시뮬레이션 연구 (The Performance Simulation of All-Glass Vacuum Tubes with Coaxial Fluid Conduit)

  • 이상진;현명택;박윤철;천원기;이정호
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.27-38
    • /
    • 2004
  • A numerical investigation has been carried out for a solar system, which consists of all glass solar vacuum tubes Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is filled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing all-glass solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show good agreement when compared with other experimental data demonstrating the reliability of the present model.

ASPEN PLUS®를 이용한 태양열 유기랭킨사이클 열병합 발전시스템의 공동주택 적합도 분석 (Feasibility of a Solar Thermal Organic Rankine Cycle Power Plant for an Apartment Complex with Aspen Plus®)

  • 임석연;김형근;유상석
    • 대한기계학회논문집B
    • /
    • 제39권4호
    • /
    • pp.317-324
    • /
    • 2015
  • 본 연구에서는 아파트단지에 적용되는 태양열 급탕 시스템의 에너지 활용도를 높이기 위해 유기랭킨사이클을 적용하여 해석적 연구를 수행하였다. 시스템 해석은 Aspen $Plus^{(R)}$을 활용하였으며 태양열집열기는 급탕 온도와 유기랭킨 사이클의 운전 조건을 고려하여 진공관형 집열기를 적용하였다. R134a, R141a, R245fa 등의 냉매를 작동유체로 선정하였으며, 시스템 성능해석을 통하여 R245fa 냉매가 적용가능성이 가장 높게 나타났다. 비가역성 해석과 민감도 해석을 통해 유기랭킨 사이클 시스템의 효율 및 성능 확보를 위해서는 증발기와 터빈에 대한 기술 개발이 매우 중요하다는 것을 밝혀냈으며, 순수 급탕으로만 활용하는 시스템에 전기 생산 설비를 추가하게 되면 약 50%의 추가적인 경제성이 확보됨을 확인하였다.