• 제목/요약/키워드: 직달 일사

검색결과 64건 처리시간 0.024초

스털링엔진 태양열 발전시스템의 성능예측(집열기.수열기 및 엔진.발전기 시스템의 조화) (Performance Prediction of a Solar Power System with Stirling Engine (Matching Collector/Receiver with Engine/Generator Systems))

  • 배명환;장형성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.794-799
    • /
    • 2001
  • The simulation analyses of a solar power system with monolithic concentrator by using a stirling engine are carried out to predict the system performance in four test sites. The site has different intensities and distributions of direct solar radiation respectively. Seoul, Pusan and Cheju in Korea, and Naha in Japan are selected as test sites. To accomplish the same demand of a 25 kW output that the power level of a system has, it needs to take the matching of collector/receiver with engine/generator systems. In such a case, also, the size of the collector is sometimes adjusted. In this study, the diameter of the collector is decided by using the solar radiation of design point, which is defined as the sum of average and standard deviation $\sigma$ of maximum direct solar radiation distribution for a day during a year in the respective test site. It is found that the average power output during the system operating time in the case of slope error ${\sigma}_s=2.5$ is within the range of 9 to 13 kW.

  • PDF

실측에 의한 국내 법선면 직달일사량 자원의 재평가 (A Revaluation of Direct Normal Insolation Data by Field Measurement in Korea)

  • 조덕기;전일수;이순명;이태규;강용혁;오정무
    • 태양에너지
    • /
    • 제20권2호
    • /
    • pp.31-42
    • /
    • 2000
  • Since the direct normal insolation is a main factor for designing any focusing solar system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1990 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $4,576kcal/m^2.day$ of the direct normal insolation was evaluated for clear day all over 16 areas in Korea. 2) Clear day's direct normal insolation of spring and summer were $4,710kcal/m^2.day$ and $4,960kcal/m^2.day$, and for fall and winter their values were $4,484kcal/m^2.day$ and $4,151kcal/m^2.day$ respectively. So, spring and summer were higher, and fall and winter were lower than the yearly mean value.

  • PDF

대구 도심과 인근 교외지역의 하절기 복사 성분 특성 연구 (Comparison and Analysis of Radiation Environment between Downtown and Suburban Area during Summer Season)

  • 최동호;이부용;오호엽
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.105-116
    • /
    • 2014
  • The objective of this study was to compare and analyze of radiation environment between downtown and suburban area by observation of short, diffuse and long-wave radiation during summer season. The followings are main results from this study. 1) The trends of long-wave radiation is increasing from May to August and the variation of daily range is decreased. It is confirmed that the temperature was closely relevant to long wave radiation. 2) During observation period, suburban area is higher than downtown the value of direct solar radiation. 3) There are much direct solar radiation in suburban area than downtown. But, it was measured much more horizontal solar radiation at the downtown area. From the this result, we can conclude that diffuse radiation play a important role at horizontal solar radiation.

국내 태양열시스템 설치를 위한 성분일사량 분석 (Analysis of Solar Radiation Components for the Installation of Solar Thermal System in Korea)

  • 조덕기;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.12-18
    • /
    • 2009
  • The Knowledge of the solar radiation components are essential for modeling many solar energy systems. This is particularly the case for applications that concentrate the incident energy to attain high thermodynamic efficiency achievable only at the higher temperatures. In order to estimate the performance of concentrating thermal systems, it is necessary to know the intensity of the beam radiation, as only this component can be concentrated. The Korea Institute of Energy Research(KIER) has began collecting solar radiation component data since January, 2002. KIER's component data will be extensively used by concentrating system users or designers as well as by research institutes. The theoretical analysis of solar radiation as a component has compared with the experimental data obtained by the KIER station. The Result of simulation analysis shows that the annual-average daily diffuse radiation on the horizontal surface is $1,457cal/m^2$ and daily direct radiation on the horizontal surface is $1,632cal/m^2$ for all over the 16 areas in Korea.

서울지역 지역계수가 적용된 직산분리 모델의 성능 비교 (Comparative Analysis of Decomposition Models with Site-fitted Coefficients for Seoul)

  • 서동현;김혜진
    • 한국태양에너지학회 논문집
    • /
    • 제39권3호
    • /
    • pp.91-102
    • /
    • 2019
  • Decomposition models are essential in TMY development and solar energy system design. Up until recently, only a few decomposition model related researches are implemented in Korea due to lack of measured direct normal solar irradiance. In contrast, numerous researches have been conducted in various countries, and some quasi-universal composition models have been recommended by several papers. In this research, three decomposition models - Watanabe model, Reindl-2 model and Engerer1 model - are selected and their site-fitted coefficients are developed using measured direct normal solar irradiance in Seoul. R-squared, RMSE, MBE of the site-fitted models are compared with the case of original coefficients and then each other. The comparison result shows that the Reindl-2 model with site-fitted coefficients is best suitable for Seoul. Further researches will be conducted to find the best model using more various measured data of Korean cities and site-fitting methods.

대기오염에 의한 대기투과도 감쇠에 대한 연구 (Attenuation of the Atmospheric Aerosol Transmissivity due to Air Pollution)

  • Kim, Yoo-Keun;Lee, Hwa-Woon;Lee, Yong-Seob
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제11권E호
    • /
    • pp.23-29
    • /
    • 1995
  • 산업 도시 부산에서 관측된 기상자료와 대기오염 자료를 이용해 대기오염과 대기투과도의 상호 관계를 연구하였다. 부산에서 대기오염에 의한 대기투과도를 예측하는데 경험적인 모델을 구축하기 위해 여러 기상 요소와 대기오염을 사용하였고, 이 결과를 Yamamoto et al.(1968)에 의한 대기투과도 계산 방법과 비교하였다. 그 결과, 두 방법에 의한 결과는 좋은 상관을 나타내었다. 따라서 본 연구에 의해 제시된 대기오염의 모수화는 부산에서 대기투과도와 직달일사량을 신뢰성 있게 예측하는 하나의 방법이라 생각된다. Relationship between atmospheric aerosol transmissivity and air pollution was analyzed using observed data in a large industrial city, Pusan, Korea. The atmospheric aerosol transmissivity predicted by method of present study in Pusan was assessed by the method of Yamamoto et al.(1968) in order to set up an empirical model to predict the transmissivity using the various meteorological parameters and air pollution. As a result, good correlation between these tow method re observed. Thus, it is possible to conclude that the parameterization of air pollution suggested by this study is another method to give reliable estimate of atmospheric aerosol transmissivity and direct solar irradiance in Pusan.

  • PDF

PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능 (Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator)

  • 황선엽;강태곤;부준홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF

베네치안 블라인드 슬랫각도 형태변화에 따른 주광성능에 관한 연구 - Radiance Program 중심으로 (An Evaluating of Daylighting Performance by Venetian Blind Shapes Type Change - Centre on Radiance Program)

  • 임태섭;박종명;임정희;김병선
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.59-66
    • /
    • 2013
  • Current Architectural Facade Designs have been trending to increased glass areas resulting in increasing impact on interior lighting and daylighting. In regards to indoor environmental quality, the increase in window space has a large impact on the daylighting received which ultimately impacts the liveability of a space. Especially when considering seasons, in the summer, excessive daylighting can result in glare as well as put an increased load in conditioning the air space further reducing energy efficiency. As a result, in order to improve the sustainability performance of a building, it is important to limit the natural lighting exposure to properly meet the needs and conditions of the building occupants. One of the most representative features to limit excessive sunlight exposure, is to incorporate operable blind systems. To this end, this research has been based on simulations performance through the Radiance Program. Radiance is capable of analyzing performance of daylight and impact of sunlight. Through analysis of different slat angles and blind shapes, impact and minimization of energy usage was evaluated. Furthermore, seasonal analysis was performed in order to understand the effects of seasonal climate factors. Ultimately this research provides an analysis of operable blinds optimization and effects of blind shape, control factors and angle of shading.

10 kW급 접시형 태양열발전시스템 사업모델 개발 및 운전특성 분석 (Development of 10 kW Dish-Stirling System for Commercialization and Analysis of Operating Characteristics)

  • 김종규;이상남;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.118-124
    • /
    • 2010
  • In order to develop commercial model of 10kW dish-Stirling solar thermal power system, modification for the exiting facility was taken for a year as a Leading Project in KIER. During the project, solar tracking system, control and monitoring system and high durability reflector were developed and long term operation were performed. The solar tracking system was tested for four months to investigate the degree of precision and adapted to the control system for an actual operation from October in 2009. The sun tracking accuracy of ${\pm}4$ mrad using modified control system was obtained and the system operated successfully during the experimental period. The monitoring system displays engine pressure, electric generation amounts, generator RPM, receiver temperatures, and etc. from Stirling engine and weather data of Direct Normal Irradiation, Horizontal Global Insolation, wind speed & direction, and atmosphere temperature from weather station. According to the operating results in a clear sky day, electric power of 6,890 W was generated at the DNI value of 850 W/$m^2$ and the averaged solar-to-electricity efficiency during a whole day reached to 18.99%. From the overall operating results, linear power generation trend could be observed with increasing DNI value. The solar-to-electricity efficiency achieved to 19% around the DNI value of 700 W/$m^2$ and increased to 20% when the DNI value goes up to 900 W/$m^2$.

대규모 태양열발전 기본설계 및 동특성 계산 (Basic Design and Dynamic Simulation of Large Scale Solar Thermal Power Plant)

  • 김종규;강용혁;김진수;윤환기;유창균;이상남
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.55-61
    • /
    • 2007
  • This paper describes the procedure and calculation results of basic design and transient variation of performance of 1 MWe large scale solar thermal power plant (STPP) by using the commercial software of THERMOFLEX and TRNSYS, respectively. In order to simulate the transient variation of STPP, the results of basic design are necessary. The design standard of the STPP is 1 MWe generation with solar only at high DNI condition and then 0.6 MWe output power for 1 hour using stored energy when the DNI becomes lower unable to operate normally. The results of basic design show the important design data of flow rates, water/steam conditions at each equipments and the estimated efficiency of STPP. In addition, dynamic simulation results of STPP are predicted and plotted for one year and three different days weather data of Daejeon.