• Title/Summary/Keyword: 직달 일사

Search Result 64, Processing Time 0.029 seconds

Design and Performance Prediction of Power System in a Solar Stirling Engine for 9 kW Output (9 kW 출력용 태양열 스털링엔진 발전시스템의 설계와 성능예측)

  • Bae, Myung-Whan;Kang, Sang-Yul
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2198-2204
    • /
    • 2003
  • In order to make a match of the insufficient direct solar radiation, in this study, the target output is lowered to 9 kW smaller than 25 kW in former studies. It is also necessary to match the collector/receiver with engine/generator systems to accomplish the power level of a system. The simulation analyses of a dish solar power system with stirling engine are totally carried out to predict the system performance with the designed values. In addition, an influence of direct solar radiation on system performance and operation control is discussed in simulation. It is found that the diameter of concentrator could be made small to 8 m regardless of slope errors with 2.5 and 5.0 mrad radiation, and the operation range of mean pressure control. is wide even if the direct solar radiation is a quit low.

  • PDF

Revaluation of Solar Radiation Energy Resources in Korea (국내 태양복사에너지 자원의 재평가)

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.15-21
    • /
    • 2009
  • Since the solar radiation is main input for sizing any solar photovoltaic system and solar thermal power system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 and direct normal insolation data since December 1992 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar energy system users as well as by research institutes. Among some significant results, the yearly averaged horizontal global insolation was turned out 3.60 kWh/$m^2$/day and the yearly mean 2.62 kWh/$m^2$/day of the direct normal insolation was evaluated for all days.

Performance comparisons of the glass evacuated tube solar collectors of different absorber tubes (진공관형 태양열 집열기의 흡수관 형상 변화에 따른 성능 비교)

  • Kim, Yong;Seo, Tae-Beom;Yun, Seong-Eun;Kim, Young-Min
    • New & Renewable Energy
    • /
    • v.2 no.1 s.5
    • /
    • pp.56-65
    • /
    • 2006
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam irradiation) on thermal performance of the collector are studied. However, the solar irradiation consists of the beam irradiation as well as the diffuse irradiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector, These effects are considered in this study experimentally and numerically. The accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

Intercomparison of Shortwave Radiative Transfer Models for a Rayleigh Atmosphere (레일리 대기에서 단파 영역에서의 복사전달모델 결과들의 상호 비교)

  • Yoo, Jung-Moon;Jeong, Myeong-Jae;Lee, Kyu-Tae;Kim, Jhoon;Ho, Chang-Hoi;Ahn, Myoung-Hwan;Hur, Young-Min;Rhee, Ju-Eun;Yoo, Hye-Lim;Chung, Chu-Yong;Shin, In-Chul;Choi, Yong-Sang;Kim, Young Mi
    • Journal of the Korean earth science society
    • /
    • v.28 no.3
    • /
    • pp.298-310
    • /
    • 2007
  • Intercomparison between eight radiative transfer codes used for the studies of COMS (Communications, Ocean, and Meteorological Satellite) in Korea was performed under pure molecular, i.e., Rayleigh atmospheres in four shortwave fluxes: 1) direct solar irradiance at the surface, 2) diffuse irradiance at the surface, 3) diffuse upward flux at the surface, and 4) diffuse upward flux at the top of the atmosphere. The result (hereafter called the H15) from Halthore et al.'s study (2005) which intercompared and averaged 15 codes was used as a benchmark to examine the COMS models. Uncertainty of the seven COMS models except STREAMER was ${\pm}4%$ with respect to the H15, comparable with ${\pm}3%$ of Halthore et al.'s (2005). The uncertainty increased under a large $SZA=75^{\circ}$. The SBDART model generally agreed with the H15 better than the 6S model, but both models in the shortwave infrared region were equally good. The direct solar irradiance fluxes at the surface, computed by the SBDARTs of four different users, were different showing a relative error of 1.4% $(12.1Wm^{-2})$. This reason was partially due to differently installing the wavelength resolution in the flux integration. This study may be useful for selecting the optimum model in the shortwave region.

Comparative Studies on Heating and Cooling Loads' of a Building Varied by Annual Weather Data (연도별 기상데이터를 활용한 건물의 냉.난방부하 특성 비교)

  • Lee, Ji-Hoon;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.35 no.3
    • /
    • pp.265-270
    • /
    • 2011
  • The purpose of this study is to compare and analyze the differences of a building's heating and cooling loads depending on the weather variation. Followings are the results. The temperature, humidity and wind speeds of standard year are bigger than those of 2006~2009. The 2006~2009's total horizontal solar irradiance is greater than that of standard year, and the direct solar irradiance of standard year is bigger in winter and vice versa in summer. As results of simulation on heating and cooling loads, it is difficult to find out the bilateral influences between maximum thermal loads and annual's. The equivalent-time operating ratio(EOR) is defined on this study to estimate the differences between year and year, and the EOR of standard year shows low value comparing to 2006~2009 years'.

Intercomparison of Shortwave Radiative Transfer Models for Aerosol-laden Atmospheres (에어러솔 대기에서 단파 영역에서의 복사전달모델들의 상호비교)

  • Yoo, Jung-Moon;Jeong, Myeong-Jae;Lee, Kyu-Tae;Kim, Jhoon;Rhee, Ju-Eun;Hur, Young-Min;Kim, Bo-Mi;Lee, Yun-Gon;Lee, Jae-Hwa;Yoon, Jong-Min;Lee, Won-Hak
    • Journal of the Korean earth science society
    • /
    • v.29 no.2
    • /
    • pp.128-139
    • /
    • 2008
  • Intercomparison among the three radiative transfer models (RTMs) which have been used in the studies for COMS, was carried out on the condition of aerosol-laden atmospheres. Also the role of aerosols in the atmospheric radiation budget was analyzed. The results (hereafter referred to as H15) from Halthore et al.'s study (2005) were used as a benchmark to examine the models. Aerosol Radiative Forcing (ARF) values from the three RTMs, calculated under two conditions of Aerosol Optical Thickness (AOT=0.08, 0.24), were systematically underestimated in comparison to H15 in the following shortwave components; 1) direct and diffuse irradiance at the surface, 2) diffuse upward fluxes at the surface and the top of the atmosphere, and 3) atmospheric absorbance. The ARF values for the direct and diffuse fluxes at the surface was $-10{\sim}-40Wm^{-2}$. The diffuse upward values became larger with increasing both AOT and Solar Zenith Angle (SZA). Diffuse upward/downward fluxes at the surface were more sensitive to the SZA than to the atmospheric type. The diffuse downward values increased with increasing AOT and decreasing SZA. The larger AOT led to surface cooling by exceeding the reduction of direct irradiance over the enhancement of diffuse one at the surface. The extinction of direct solar irradiance was due mainly to water vapor in tropical atmospheres, and to both ozone and water vapor in subarctic atmospheres. The effect of water vapor in the tropics was $3{\sim}4$ times larger than that of the ozone. The absorbance values from the three RTMs agree with those from H15 within ${\pm}10%$.

Analysis of Direct and Diffuse Radiation in Plastic Greenhouse (플라스틱 하우스의 직달(直達) 및 산란(散亂) 일사량(日射量) 해석(解析))

  • Koh, Hak-Kyun;Kim, Moon-Ki;Kim, Yong-Hyeon
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.13-24
    • /
    • 1989
  • Direct and diffuse components of solar radiation were measured inside and outside a single-span plastic greenhouse. To analyze the direct solar radiation inside the plastic greenhouse, the cross-section of the greenhouse was assumed to be circular. Then the direct solar radiation transmitted into the greenhouse was calculated theoretically, and compared with the experimental measurements. The results are summarized as follows: (1) The transmissivities of total solar radiation were about 65% on cloudy days and 50% on clear days. For cloudy days, the transmissivity of the total solar radiation was regarded as the transmissivity of sky diffuse radiation. (2) The ratio of the inside effective scattered component of direct solar radiation to the diffuse radiation was 60-65%. (3) It appeared that the seasonal variation of the transmissivity of total solar radiation was adversely affected by the transmissivity of direct solar radiation and the effective scattered coefficient. But the effect of the transmissivity of direct solar radiation was dominant factor. (4) Computer simulation showed that the inside direct solar radiation was decreased as the floor of the plastic greenhouse was higher. (5) The predicted value of the inside direct solar radiation was 3.3% to 29.0% higher than the measured value.

  • PDF

Preliminary Simulation Study on 1 MWe STP System in China (중국 1 MWe급 태양열발전시스템에 대한 기초 운전해석)

  • Yao, Zhihao;Wang, Zhifeng;Kang, Yong-Heack;Kim, Jong-Kyu;Wei, Xiudong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.698-701
    • /
    • 2007
  • DAHAN, the first 1 MWe Solar Power Tower system locates north to Beijing where nearby The Great Wall is now under construction with cooperation between China and Korea. Results in predicting the preliminary performance of this central receiver system are presented in this paper. Operating cycles under some typical weather condition days are simulated and commented. These results can be used to assess the impact of alternative plant designs or operating strategies on annual energy production, with the final objective being to optimize the design of central receiver power plants. Two subsystems are considered in the system simulation: the solar field and the power block. Mathematic models are used to represent physical phenomena and relationships so that the characteristics of physical processes involving these phenomena can be predicted. Decisions regarding the best position for locating heliostats relative to the receiver and how high to place the receiver above the field constitute a multifaceted problem. Four different kinds of field layout are designed and analyzed by the use of ray tracing and mathematical simulation techniques to determine the overall optical performance ${\eta}_{field}$ and the spillage ${\eta}_{spill}$.The power block including a Rankine cycle is analyzed by conventional energy balance methods.

  • PDF

Study on the Large Scale Solar Thermal Power Plant System by Using the TRNSYS Program (TRNSYS를 이용한 대규모 태양열발전시스템 성능 연구)

  • Kim, Jong-Kyu;Kang, Yong-Heack;Kim, Jin-Su;Lee, Sang-Nam;Yu, Chang-Kyun;Yun, Hwan-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.176-179
    • /
    • 2006
  • This paper describes the procedure of the basic design and transient variation of performance for a 1MWe large scale solar thermal power plant system (STPPS) by using the commercial software tool of TRNSYS. In order to simulate the transient variation of STPPS's performance, the basic design of STPPS are preceded by using the THERMOFLEX, Three different days of DNI weather data of Daejeon in 2005 are used to calculate the performance. For a high DNI data values, the general ing power of 1.1 MWe and flow rate of 1.4kg/s at $804W/m^2$ are good agreement with the basic design value of 1.0 MWe, 1.36 kg/s at $800 /m^2$. Using the other weather data of low and sudden decreasing DNI values, the results show that the output power and flow rate follow well the DNI variation. Based on the results, it is allowed to use the Program to estimate the performance of STPPS for variety of DNI data.

  • PDF

Analysis of Solar Radiation Components in Korea (국내 일사량의 성분 분석)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.8-12
    • /
    • 2009
  • The Knowledge of the solar radiation components are essential for modeling many solar energy systems. This is particularly the case for applications that concentrate the incident energy to attain high thermodynamic efficiency achievable only at the higher temperatures. In order to estimate the performance of concentrating thermal systems, it is necessary to know the intensity of the beam radiation, as only this component can be concentrated. The Korea Institute of Energy Research(KIER) has began collecting solar radiation component data since August, 2002. KIER's component data will be extensively used by concentrating system users or designers as well as by research institutes. The Result of analysis shows that the annual-average daily diffuse radiation on the horizontal surface is $1,458cal/m^2$ and daily direct radiation on the horizontal surface is $1,632cal/m^2$ for all over the 16 areas in Korea.

  • PDF