• Title/Summary/Keyword: 직경

Search Result 6,082, Processing Time 0.034 seconds

Stand Table of Pinus rigida Miller and Populus euramericana Guiner (리기다소나무와 이태리포를러의 임분표(林分表))

  • Lee, Heung Kyun;Choi, Jong Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.41 no.1
    • /
    • pp.19-25
    • /
    • 1979
  • The study was carried out to determine the frequency distribution of trees by diameter classes according to the method of Bruce and Reineke's alignment with the data of pitch pine (Pinus rigida Miller) and Italian poplar (Populus euramericana Guinier) which are prepared for the purpose of yield table construction. The results obtained are summarized as follows: 1. All through the tree species studied, when their diameters were larger, their distribution range became wider, while the percentage of their distribution frequency became lesser. 2. As for frequency percentage of trees in an average D.B.H. of stands, it became smaller when average D.B.H. of the stand is larger: the percentage of pitch pine stand is 36.2 and that of Italian poplaris 29.0. 3. In case of smaller D.B.H. under the average, the larger their D.B.H. became, the lesser the cumulative frequency percentages became.

  • PDF

The diameter and base curve changes of soft contact Lens by protein deposition (단백질 침착에 의한 소프트콘택트렌즈의 직경 및 곡률반경 변화)

  • Park, Mi-Jung;Cho, Gyu-Tae;Shin, Sung-Hwan;Lee, Heum-Sook;Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.165-171
    • /
    • 2005
  • The aim of the study was to investigate the diameter and base curve changes of soft contact lens by protein deposition. Soft contact lenses were soaked in artificial tear or protein solution which had the same composition with tear for 2min, 10min, 30min, 1hr, 3hr, 6hr, 12hr, and 24hr. Diameter and base curve changes of soft contact lenses were examined by using the high speed camera(Fastcam ultima 1024). The longer the soaking time of soft contact lenses in the artificial tear, the diameter and base curve changes of soft contact lenses was more increased. In the case of soft contact lenses adsorbed only protein, the similar pattern was shown and the diameter and base curve were decreased. However, the influence of calcium ion was found to be less than that of protein. These results suggest that the tear protein causes the diameter and base curve decrease of soft contact lens, which might be related to the discomfort after soft contact lens wearing.

  • PDF

Evaluation of Structural Behavior of Large Studs Using Partial Composite Beams (부분합성보를 이용한 대직경 스터드의 구조거동 평가)

  • Shim, Chang Su;Lee, Pil Goo;Ha, Tae Yul
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.425-432
    • /
    • 2004
  • Large studs were suggested not only for the design of steel-concrete composite bridges with simplified sections but also for the shear connection in precast decks requiring uniform distribution of shear pockets. Based on the push-out test results on studs with diameters of more than 25 mm, partial composite beams with 40%-degree shear connection were fabricated, and static tests were performed. The ultimate strength and horizontal shear load redistribution of partial composite beams, which have parameters of stud shank diameters and distribution, were evaluated, and group failure in the shear span was observed. Since the flexural strength of composite beams are dependent on the strength of their shear connection, the strength of the stud connection was estimated and it showed considerably higher shear strength. From the load-slip curves, the sufficient ductility and load redistribution of large studs were confirmed. Uniformly distributed large studs can provide proper ultimate behavior of composite beams.

Physical Property of Aramid ATY filament According to the ATY Nozzle Diameter (ATY Nozzle 직경변화에 따른 Aramid 단사의 ATY 물성)

  • Choi, La-Hee;Park, Mi-Ra;Ma, Hye-Young;Kang, Yun-Hwa;Kim, Seung-Jin
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.65-65
    • /
    • 2012
  • The air texturing공정은 노즐에서 전달되는 초음속 에어기류에 의해 overfeed를 수반하여 yarn속 fiber가 뒤얽혀 loop와 crimp를 발달시키는데, 고강력 고탄성율 고내열성 내절단성 등의 특성을 가지는 아라미드섬유를 에어 가공사로 가공 할 경우 가공 전 필라멘트 상태일 때 보다 표면에 생기는 loop로 인하여 촉감이 좋아지고 또한 타 소재와 접착 시 접착제 담지 성능이 향상 되어 접착력이 상승되고, 이를 통해 보강재로서의 기능이 강화되는 반면 역학물성이 기존의 아라미드 보다 저하되는 약점을 가지고 있어 최근 ATY 공정조건이 ATY 사의 구조와 물성변화에 미치는 영향에 대한 많은 연구결과가 발표되고 있다. 본 연구에서는 Aiki air jet texturing machine에서 $Heracron^{(R)}$ para-aramid(840, 1000d, 1500d)를 사용하여 ATY nozzle의 직경을 0.6, 0.75, 1, 1.2mm로 변화를 주어 12개의 para-aramid ATY 시료를 제조하여 이들의 섬도, 강신도, 초기탄성률, 열수축률 그리고 형태불안정성(instability)등의 물성변화를 분석하여 다음과 같은 결과를 얻었다. 노즐의 직경이 증가함에 따라 사 내의 filament간의 움직임이 자유로워 교락이 증가하고 루프가 형성되어 단위길이 당 mass가 커지므로 섬도가 미세하게 증가하는 것을 볼 수 있다. 또한 직경이 증가할수록 절단강도와 초기탄성률은 감소하고 절단신도가 증가하는 경향을 볼 수 있는데 이는 축 방향으로의 배열이 적어져 하중을 분담하는 portion이 감소하고 사의 loop형성이 많아짐으로서 상대적으로 인장력에 대응하는 fiber의 수가 적어지기 때문으로 사료된다. 이는 현미경 관찰로 확인할 수 있는데 직경이 증가함에 따라 사의 loop의 엉킴이 증가하고 filament가 조밀한 것을 확인할 수 있다. 직경 변화에 따른 건 습열 수축률은 1% 미만의 매우 낮은 값으로 영향을 받지 않는 것을 확인 할 수 있는데 para-aramid의 열적특성의 안정성에 기인하는 것으로 사료되며 ATY의 불안정성은 노즐 직경 증가에 따른 어떤 경향성을 찾아볼 수 없었지만 840d, 1000d, 1500d로 섬도가 증가함에 따라 사의 불안정성이 증가하였다.

  • PDF

Diameter, Fault Diameter and Average Distance between Two Nodes in Z-cube Network (Z-cube 네트워크의 직경, 고장직경과 정점간 평균거리)

  • Gwon, Gyeong-Hui;Lee, Gye-Seong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.1
    • /
    • pp.75-83
    • /
    • 1999
  • recently, a new hypercube-like interconnection network, the Z-cube, was proposed. The Z-cube retains most good topological properties, however, its node degree is 3/4 of hypercube's one. Considering hardware implementations, the Z-cube is a good alternative to the hypercube. In this paper, we obtained the diameter, fault diameter and the average distance between two nodes to evaluate the communication performance of the Z-cube. The recursive structure, the shortest path between two nodes I Z-cube and recurrence relation on the average distance were deduced, and node disjoint path was introduced. Although it is generally expected that the communication performance in an interconnection network with reduced node degree falls as much as that, this paper shows that the Z-cube's diameter is the same as the hypercube's one and the average distance between two nodes in Z-cube is about 1.125 times the average distance between two nodes in the hypercube and the fault diameter of Z-cube ranges approximately from 1.4times to 1.7times the fault diameter of the hypercube.

  • PDF

Effects of Pile Diameter on the Plugging Rate and Bearing Capacity of Open -Ended Piles (말뚝직경이 재단말뚝의 폐색정도와 지지력에 미치는 영향)

  • Baek, Gyu-Ho;Kim, Yeong-Sang;Lee, Seung-Rae
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.85-94
    • /
    • 1996
  • Model pile tests, using a calibration chamber in which the stress state and the relative density can be controlled, were performed in order to study the effects of pile diameter on the plugging rate and bearing capacity of open-ended pile. The model piles used in the test series were devised so that the bearing capacity of an open-ended pile could be measured out into three components. The test results showed that fully plugging depth of an open -ended pile increased with increase in pile diameter and soil density. Moreover, it was found that unit plug capacity decreased with increase in pile diameter, though the penetration ratio or plugging rate of piles was constant. However, the existing formulae for estimation of plug capacity give plug capacity which is constant or increased with increase in pile diameter, when penetration ratio or plugging rate of piles is equal. Thus, it is proposed that the effect of pile diameter as well as plugging rate on bearing capacity of pile must be considered in plug capacity estimation.

  • PDF

Tensile Strength Changes of Pinus densiflora root in Fire Damaged Forest Area (산불피해지에 있어서 소나무 뿌리의 인장강도특성 변화)

  • Cha, Du Song;Oh, Jae-Heun;Lee, Jung Su
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.4
    • /
    • pp.392-397
    • /
    • 2008
  • To characterize the root strength changes of Pinus densiflora by elapsed years after forest fire, we measured and analyzed the tensile force and strength of the roots using the universal testing machine for 4 years. The deterioration rate of the root strength was higher in small diameter class than that in large diameter class. Especially, the deterioration was highest of the root strength at the second year in all surveyed diameter classes and the mean deterioration rate of the root strength was 61% by that time. The tensile strength based on the simulation by ordinary differential equations deteriorated more than 50% in all diameter classes within 2 years after forest fire.

Implementation of the Linear Regression Equation for Gestational Age Prediction in the 3D Ultrasonography (3차원초음파에서 임신주수 예측을 위한 선형회귀방정식의 구현)

  • Yang, SungHee;Lee, Jin-Soo;Kim, Jung-Hoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.276-282
    • /
    • 2015
  • Fetal cerebellum is grow depending on the gestational age, measurement of transverse cerebellar diameter(TCD) is being used import indicator of fetal growth prediction in clinical. In this study, the subjects were normal pregnant women 20~37 week of gestation, and the volume scan was conducted on the 340 subjects. The research reports was indicated by regression curve the growth of fetal TCD in accordance with the gestational age. It got to the value of the results from a linear regression equation. Measurement fetal TCD using 3D US was statistically significant(p<0.001) and useful in the prediction of gestational age. TCD increases with gestational age can also distinguish between the normal fetal and prediction of accurate gestational age of fetal growth retardation. If the basic data of the present study, ongoing research is performed, the TCD using by 3D US are expected to be usefully applied in the correct prediction gestational age.

Estimation of Diameter and Height Growth in Pinus thunbergii Stands Using Linear and Nonlinear Growth Functions (곰솔임분(林分)의 직경(直徑) 및 수고생장(樹高生長) 추정(推定)에 관한 연구(硏究))

  • Park, Myeong Sookn;Chung, Young Gwann
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.1
    • /
    • pp.47-54
    • /
    • 1999
  • To estimate optimal tree diameter and height growth function in Pinus thunbergii stands with site index of 12 class, quoted from two linear models of linear transformation(1) and linear transformation (2) and four non-linear models of exponential, Gompertz, Chapman-Richards, and Weibull etc.. Analyzed correlation among the estimated tree diameter and height by these function models, and observed diameter and height growth were compared. In the results of tree diameter and height growth estimation by stand age, non-linear models showed better appropriation than linear model and Chapman-Richards model was most fitted for tree height growth but few, if any, differences among their nonlinear models. Therefore, it is consider to be much more study about non-linear model to estimate tree diameter and height growth in the actual stands hereafter.

  • PDF

A Study of Spray Characteristics of the Rotating Fuel Nozzle with Orifice Diameters (회전연료노즐의 오리피스직경에 따른 분사특성연구)

  • Lee, Mae-Hoon;Jang, Seong-Ho;Lee, Dong-Hun;Choi, Seong-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.258-263
    • /
    • 2010
  • An experimental study was performed to understand spray characteristics of the V type rotating fuel nozzle with orifice diameters by using high speed rotational system. The experimental apparatus consist of a high speed rotational system, fuel injection system and acrylic case. The droplet size and velocity were measured by PDPA(Phase Doppler Particle Analyzer) and spray was visualized by using Nd-Yag laser-based flash photography. From the test results, droplet diameters are reduced with increasing orifice diameter and the optimum injection orifice diameter is 2.6 mm. When increasing orifice diameter over than 2.6 mm, droplet diameter is not decreased with increasing orifice diameter. This is due to the irregular distribution of the liquid sheet around the inner surface of injection orifice.

  • PDF