• Title/Summary/Keyword: 지하공간 화재

Search Result 235, Processing Time 0.025 seconds

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.

A study on the relationship among traffic accidents, fire occurrences and tunnel characteristics in local road tunnels (국내 도로터널내 발생 교통사고, 화재사고 및 터널특성 관계 연구)

  • Kim, Hyo-Gyu;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.3
    • /
    • pp.199-211
    • /
    • 2004
  • As the length of local tunnels is getting longer, the demand for tunnel safety attracts more attention. But only a few information can be found concerning traffic and fire accidents occurred in local tunnel, and full-fledged studies had not been carried out to fulfill the expectation of the tunnel users. This study aims at collecting and analyzing the data on traffic and fire accidents in local road tunnels and providing the fundamental data for the tunnel fire safety evaluation. Focus is placed on quantifying the relationship among traffic accidents, fire occurrences and tunnel characteristics.

  • PDF

Development of the Fire Simulator Based on Virtual Reality (가상현실 기반 소방안전대응 시뮬레이터 개발)

  • Choi, Byung-Il;Han, Yong-Shik;Kim, Myung-Bae;Cha, Mu-Hyun;Lee, Jae-Kyung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.195-198
    • /
    • 2010
  • 가상환경에서 화재를 재현, 체험 및 소방훈련을 수행할 수 있는 실감영상기반 소방안전 대응 훈련 시뮬레이터 개발하고자 한다. 이를 위해 소방훈련 시뮬레이터를 설계하고, 대상 화재 공간을 가상현실에 구현하였으며 화재 대응 시나리오 지침을 마련한 후 화재시나리오에 따른 화재시뮬레이션을 수행하였다. 또한 전산해석 결과를 토대로 한 화재상황을 가상공간 구현하는 시스템을 구축하였다. 팀 훈련이 가능하도록 하는 팀 훈련 모듈과 열기를 체험할 수 있는 물리 체험모듈을 장착하여 모듈을 추가하여 6팀이 고층 빌딩 및 지하역사에서 소방안전 팀 대응 훈련을 할 수 있는 소방안전 대응 시뮬레이터 시스템을 개발하였다.

  • PDF

The Occupant Load Density of Sunken Area in Multiple Occupancy Building with Underground Facility (지하연계복합건축물의 선큰 재실자밀도 분석)

  • Kim, Woon Hyung;Kim, Jong Sung;Lee, Yong Jae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.80-81
    • /
    • 2013
  • 최근 제정 시행되고 있는 지하연계 복합건축물에 대한 다양한 연구가 진행되고 있다. 그러나 화재위험성이 높은 지하 공간의 경우, 아직까지 관련 규정의 근거가 미약하여 현실적인 피난안전 설계에 어려움을 가지고 있다. 본 연구에서는 피난 계획을 위한 로우 데이터를 확보하고자 현재 사용 중인 선큰을 대상으로 실제 유동인구를 측정하여 재실자 밀도를 분석하였다. 선큰으로 연결되는 출입구들의 유동인구와 함께 유동계수를 측정하였으며 선큰내의 재실자 밀도 산정을 통하여 선큰의 대피기능을 위한 연구 진행의 토대를 마련하였다.

  • PDF

Design of intelligent fire detection / emergency based on wireless sensor network (무선 센서 네트워크 기반 기능형 화재 감지/경고 시스템 설계)

  • Yuk, Ui-Su;Kim, Seong-Ho
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.367-371
    • /
    • 2007
  • 최근 여러 지역에서 발생되는 지하철 참사 및 대형화재 또는 지하철 역사, 대형 지하상가, 백화점, 지하공간, 대형쇼핑센터, 숙박업소, 공공건물등 대형 다중이용시설 등에서 발생될 수 있는 예측 불가능한 인재, 천재지변에 안전하게 대피하기 위한 수단으로 비상등 및 여러 감지기들이 소방법 개정으로 의무설치 하고 있다. 비상등 및 감지기들은 비상시 위험 감지 및 경고 전파를 위해 사용되는데 방음벽이나 격벽, 경고 거리의 제한으로 인해 경고 전달의 어려움이 있다. 본 논문에서는 무선 데이터 전송기능 및 경고등, 음성전파 기능을 갖는 무선 지능형 화재 감지/경고시스템을 설계하고자 한다.

  • PDF

A Study on the Planning of Escape Facilities of Underground Space at Fire. -a case study at Underground Shopping Street- (화재시 지하공간의 피난시설계획에 관한 연구 -지하가를 중심으로-)

  • 이원석;이경회
    • Fire Science and Engineering
    • /
    • v.4 no.1
    • /
    • pp.13-19
    • /
    • 1990
  • Recently, the expansion of underground shopping street has a tendency to make a large maze in urban underground space. As the passers -by in underground streets have little information about these spaces, there can be a great danger at fire. From this point of view, this study aims at offering the basic data which needs to make a reasonable planning of escape facilities of underground shopping street. Therefore, safe performance evaluation program is developed for evaluating inhabitants' safety at each model. This program is composed of systematic equations which generalize each phenomenon at fire.

  • PDF

A Study on the Law History of Tunnel Disaster Prevention in Korea (국내 터널관련 방재법령의 변천에 관한 연구)

  • Kim, Se-Jong;Kim, Dong-Jun;Kim, Jung-Hee;Kwon, Young-Jin;Han, Byung-Chan;Kim, Jae-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.235-240
    • /
    • 2009
  • 지하에 건설되는 터널은 구조상 반 밀폐적인 특성을 가지고 외부와 차단되어 있기 때문에 화재발생시 연기에 의한 질식의 위험성이 크고 다수의 이용자들이 쉽게 패닉현상에 빠지게 되고 많은 연기와 유독가스에 노출되어 생명의 위협을 받게 된다. 또한 연기와 유독가스 호흡에 의한 체내유입은 인체상의 여러 가지 부작용을 초래하는 등 피해를 가져올 수 있다. 이러한 피해를 예방하고 최소화하기 위해 방재설비를 시설하고 운영하는데 국내의 방재시설에 대한 규정은 지하공간을 관리 관장하는 기관과 용도에 따라 각각 다르게 적용하고 있어 터널관련 방재시설의 변천에 대하여 알아보고 현재의 설치 기준과 문제점을 살펴보았다.

  • PDF

A Study on the Law History of Tunnel Disaster Prevention in Korea (국내 터널관련 방재법령의 변천에 관한 연구)

  • Kim, Se-Jong;Kim, Dong-Jun;Kim, Jung-Hee;Kwon, Young-Jin;Han, Byung-Chan;Kim, Jae-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.45-50
    • /
    • 2009
  • 지하에 건설되는 터널은 구조상 반 밀폐적인 특성을 가지고 외부와 차단되어 있기 때문에 화재발생시 연기에 의한 질식의 위험성이 크고 다수의 이용자들이 쉽게 패닉현상에 빠지게 되고 많은 연기와 유독가스에 노출되어 생명의 위협을 받게 된다. 또한 연기와 유독가스 호흡에 의한 체내유입은 인체상의 여러 가지 부작용을 초래하는 등 피해를 가져올 수 있다. 이러한 피해를 예방하고 최소화하기 위해 방재설비를 시설하고 운영하는데 국내의 방재시설에 대한 규정은 지하공간을 관리 관장하는 기관과 용도에 따라 각각 다르게 적용하고 있어 터널관련 방재시설의 변천에 대하여 알아보고 현재의 설치 기준과 문제점을 살펴보았다.

  • PDF

The study on performance evaluation of heat resistance and smoke control system using air-curtain system in tunnel (터널용 에어커튼 시스템의 내열 및 제연 성능 평가 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Yang-Kyun;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.743-755
    • /
    • 2018
  • Tunnel is a semi-closed structure similar to underground space where the smoke generated from fire fills the space fast while escaping from the space slow. Because of such characteristics, when the fire breaks out by traffic accident, the vehicles are jammed making it difficult for the people to evacuate from the scene as well as for the fire engine to gain access to the scene. For such reasons, tunnels are globally categorized into some disaster classes for differentiated facilities and operation approaches. In Korea, less than a 1 km-long tunnel accounts for 80.0% and such a short tunnel which is categorized into Class III is not required to have smoke control system. In this study, a full-scale fire test was conducted in a bid to apply air curtain system using heat-resistant sirocco fan to a less than 1 km-long tunnel. To that end, heat resistance test to verify the normal operation at $250^{\circ}C$ for 60 minutes was conducted. Consequently, despite of rapid rising-temperature and increasing-carbon dioxide inside the air curtain (direction of fire in tunnel), initial condition was found to have been sustained outside the air curtain (opposite direction of fire in tunnel).