• Title/Summary/Keyword: 지층두께

Search Result 81, Processing Time 0.025 seconds

A Study on the Shallow Marine Site Survey using Seismic Reflection and Refraction Method (탄성파 반사법 및 굴절법을 이용한 천해저 지반조사에 대한 연구)

  • Shin, Sung-Ryul;Kim, Chan-Su;Jo, Churl-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.109-115
    • /
    • 2008
  • It is very important to estimate the physical properties of survey area and delineate the geological basement in marine site survey for the design of offshore structures. For the purpose of providing high quality data by means of engineering site survey, it is necessary to apply several survey techniques and carry out the integrated interpretation to each other. In this study, we applied single channel seismic reflection method and OBC (Ocean Bottom Cable) type seismic refraction method at shallow marine. We used a dual boomer-single channel streamer as a source-receiver in seismic reflection survey and airgun source-the developed OBC type streamer in seismic refraction survey. We made 24 channels OBC type streamer which has 4m channel interval and each channel is composed of single hydrophone and preamplifier. We tested the field applicability of the proposed method and applied the typical seismic data processing methods to the obtained reflection data in order to enhance the data quality and image resolution. In order to estimate the geological velocity distribution from refraction data, seismic refraction tomography technique was applied. Therefore, we could successfully perform time-depth conversion using the velocity information as an integrated interpretation. The proposed method could provide reliable geologic information such as sediment layer thickness and 3D basement depth map.

Site-Investigation of Underground Complex Plant Construction by Seismic Survey and Electrical Resistivity (탄성파 및 전기비저항을 활용한 지하복합 플랜트 건설 후보지 탐사)

  • Kim, Namsun;Lee, Jong-Sub;Kim, Ki-Seog;Kim, Sang Yeob;Park, Junghee
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.10
    • /
    • pp.49-60
    • /
    • 2022
  • Underground urbanization appears to be a promising solution in response to the shortage of construction sites in the above-ground space. In this context, an accurate evaluation of a construction site ensures the long-term performance of geosystems. This study characterizes potential sites for complex plants built in underground space using geophysical methods (i.e., seismic refraction exploration and electrical resistivity survey) and in situ tests (i.e., standard penetration tests (SPTs) and downhole tests). SPTs are conducted in nine boreholes BH-1-BH-9 to estimate the groundwater level and vertical distribution of geological structures. The seismic refraction method enables us to obtain the elastic wave velocity and thickness of each soil layer for each cross-sectional area. An electrical resistivity survey conducted using the dipole array method provides the electrical resistivity profiles of the cross-sectional area. Data obtained using geophysical techniques are used to assess the classification of the soil layer and bedrock, particularly the fracture zone. This study suggests that geotechnical information using in situ tests and geophysical methods are useful references to design an underground complex plant construction.

Evaluation of Optimal Performance of Hydraulic Barriers in Offshore Landfill using Seepage-Advection-Dispersion Analysis under Steady State Flow (정상류하 침투·이류 분산 해석을 이용한 폐기물 해상최종처리장 차수시스템의 최적 성능 평가)

  • Hwang, Woong-Ki;Oh, Myoung-Hak;Kim, Tae-Hyung;Kim, Hyang Eun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.2
    • /
    • pp.61-68
    • /
    • 2018
  • This study was conducted to propose the optimum minimum requirement of cutoff system composed of the impermeable soil layer and vertical barrier in offshore landfill for prevention pollution leakage by seepage, advection, and dispersion numerical analyses under steady state. According to the study results, the minimum requirement of impermeable soil layer is below $1{\times}10^{-6}cm/s$ of hydraulic conductivity with more than 500 cm thickness or a system with equivalent cutoff effect. The minimum requirement of vertical barrier is below $1{\times}10^{-6}cm/s$ of hydraulic conductivity with more than 50 cm thickness or a system with equivalent cutoff effect. In addition, the vertical barrier should be embedded enough to seal securely with the impermeable soil layer for working cutoff effect.

Relationship between Hydrogeological Characteristics and Subsurface Geology in Central Busan Megacity (부산광역시 도심부 수리지질 특성과 지하지질 발달상태의 관련성)

  • Ryu, Sang-Hun;Hamm, Se-Yeong;Cha, Yong-Hoon;Jang, Seong;Jeong, Jae-Hyeong;Son, Moon;Kim, Ki-Seok
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.367-379
    • /
    • 2007
  • This study intended to evaluate hydrogeological characteristics in relation to subsurface geology data obtained from borehole, groundwater level, borehole flowmeter test, and field hydraulic tests. The regression equation of groundwater level (Y) versus ground elevation (X) is expressed by Y=0.75X-7.00 with quite high correlation coefficient of 0.78. Relationship between groundwater level and thickness of landfill, alluvium, and weathered zone results in higher correlation of groundwater level (Y) versus natural log value of weathered tone (A) than other correlations, with the regression equation Y= exp(9.974A)-14.155. The result of groundwater flow measurement in the boreholes indicates that groundwater flows towards between south and southwest, and this approximately agree with regional distribution of groundwater levels.

Numerical analysis for semi cut and cover tunnelling method (반개착식 터널 공법에 관한 수치 해석적 연구)

  • Roh, Byoung-Kuk;Park, Jong-Kwan;Baek, Seung-Kyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.2
    • /
    • pp.113-122
    • /
    • 2013
  • Recently there has been increased interest for the portal and shallow tunnel for an eco-friendly tunneling method. Semi cut & cover tunnel excavation techniques applied to concrete slab and construction and a growing number of cases, but there is no load combinations and arch concrete cross section for the applicable standards. Therefore, in this study, ground conditions and tunnel overburden thickness, thickness of backfill, overburden surface slope angle changes to a variety of conditions in order to propose standards for the semi cut & cover method was performed numerical analysis. Regression analysis method to the analysis of the results of numerical analysis, and linear regression equations derived to classify and organize a rational, economical, and safe semi cut & cover tunneling method based proposed.

Analysis of Isochrone Effect of Clayey Soils using Numerical Analysis (수치해석을 이용한 점성토 지반의 아이소크론 영향 분석)

  • Lee, Yun-Sic;Lee, Jong-Ho;Lee, Kang-Il
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.84-97
    • /
    • 2019
  • Purpose: The consolidation settlement of soft ground is dependent on the distribution of pore water pressure which is also affected by hydraulic conductivities (boundary condition) of layers, thickness of clayey soil layer and surcharge. Results: However, the current consolidation analyses are mostly based on Terzaghi's consolidation theory that assumes the initial pore water pressure ratio with depth to be constant. In this study, numerical analysis are carried out to investigate the variation of pore water pressure dissipation with depth and thickness of clayey soil layer, time, surcharge as well as drainage conditions. Conclusion: Comparative study with Terzaghi's consolidation theory is also conducted. The result shows that Terzaghi's consolidation theory should be used with caution unless it is ideally corresponded to the isochrone.

Estimation of Slime Thickness of Bored Piles by Using Borehole Electrical Resistivity Method (시추공 전기비저항 기법을 활용한 현장타설말뚝의 슬라임층 두께 평가)

  • Chun, Ok-Hyun;Lee, Jong-Sub;Park, Min-Chul;Bae, Sung-Gyu;Yoon, Hyung-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.3
    • /
    • pp.51-60
    • /
    • 2013
  • The slime, deposited in the bored pile due to falling soil particle, reduces the bearing capacity of bored pile and thus the stability of construction also decreases. The weight pendulum and iron have been used for estimating the slime thickness based on the subjective judgment and thus the previous method has a limitation of reliability. The objective of this paper is to suggest the method for estimating the slime thickness by using characteristics of electrical resistivity as scientific method. The temperature-compensation resistivity probe (TRP), which has a conical shape and the diameter of 35.7mm, is applied to the measurement of the electrical resistivity in the borehole during penetration. The field tests are carried out for estimating the slime thickness in the application site of bored pile. The slime thickness is calculated through the difference between excavation depth of borehole and measured data. Furthermore, the laboratory tests are also conducted for investigating effects of casing, time elapsing and relative density by using the specimen of slime. The laboratory test supporting the suggested method is reasonable for determining the slime depth. The paper suggests that the electrical resistivity method may be a useful method for detecting slime thickness and the method is expected to be applicable to various sites of bored piles.

공주 공산성 원형연못의 지반에 대한 탄성파 굴절법 탐사

  • 변성환;오진용;서만철
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.132-138
    • /
    • 2004
  • 탄성파 탐사는 인공지진파를 이용하여 지표면 하부의 물성을 알아내는 지구물리탐사로서 20 세기 초부터 석유탐사와 공학적 지반조사에 가장 널리 사용되었다. 굴절법 탄성파 탐사는 지층의 탄성파 속도를 알아내는 방법으로서 최근에는 석조문화재 등의 지반특성 조사에서 사용된 예가 있다. 이번 연구에서는 공주 공산성의 쌍수정 광장에 위치하는 공산성 원형연못 주변의 지반에 대하여 굴절법 탐사를 실시하였다. 쌍수정 광장은 기존의 발굴조사를 통하여 백제 추정왕궁지가 위치한 곳으로 알려졌으며, 광장 남쪽에 원형연못(상면직경 7.3 m, 바닥직경 4.78 m, 높이 3 m)도 발굴되었다. 원형연못 주변에 5개 탄성파 측선을 설치하였고, 해머 타격점과 수신기의 배열을 3가지 다른 방식을 적용하여 24 m, 31 m, 48 m 측선깊이의 굴절법 자료를 얻었다. 대체로 공산성 원형연못 주변의 지반은 3개 층으로 구성되어 있다. 각 층의 겉보기 속도는 약 261${\~}$391 m/s, 약 591${\~}$992 m/s, 약 1950${\~}$3230 m/s이며, 첫 번째와 두 번째 층의 두께는 각각 약 2${\~}$2.4 m 와 4.6${\~}$8.6 m이다. 일반적으로 최하부 층의 속도는 기반암, 상부층들의 속도는 풍화토에 대응한다. 그러나 두 번째 층의 주시곡선 형태와 속도범위는 국내 석탑 문화재 하부의 것과 유사한 것으로 보아 공산성 연못주변은 인공적인 기초지반의 가능성을 제기하며, 그렇다면 공산성 원형연못은 파내려 간 것보다는 쌓아 올렸을 것이다.

  • PDF

Static Correction of Land 3D Seismic Data (육상 3차원 탄성파 자료의 정보정)

  • Sheen Dong-Hoon;Park Jae-Woo;Ji Jun;Lee Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.145-149
    • /
    • 2002
  • The static correction, which is classified into refraction based static correction and reflection based residual static correction, removes distortions caused by irregularities of thickness or velocity in near-surface. Generally, refraction statics is a time consuming process because of high dependence on the interpreter's analysis. Therefore, for huge 3D seismic data, automatic static correction which minimizes the interpreter's analysis is required. In this research, we introduce an efficient method of refraction static correction for land 3D seismic survey.

An Experimental Study on Density Log Correction for Plastic Cased Slim Boreholes (소구경 플라스틱 케이싱 공에서의 밀도검층 보정실험)

  • Lee, Seung-Jin;Kim, Yeong-Hwa;Hwang, Byoung-Chol
    • The Journal of Engineering Geology
    • /
    • v.18 no.2
    • /
    • pp.137-144
    • /
    • 2008
  • The stand-off errors due to the different separations between the sonde and the borehole wall were measured and analyzed in 4 physical borehole models located in Kangwon National University having different densities with cylindrical and half cylindrical PVC and/or acrylic casings. The analysis of the stand-off error data based on the "spine and ribs" technique suggests a well defined rib line for each model irrespectively of the types and thicknesses of the casing, and that the gradients of the ribs are proportional to the densities of the models. By using these characteristics successful density correction could be made for the plastic casings in NX sized boreholes.