• Title/Summary/Keyword: 지진 응답

Search Result 1,205, Processing Time 0.029 seconds

Earthquake Response Characteristics of a Port Structure According to Exciting Frequency Components of Earthquakes (가진 주파수성분에 따른 항만구조물의 지진응답특성에 관한 연구)

  • Kim Doo Kie;Ryu Hee Ryong;Seo Hyeong Yeol;Chang Seong Kyu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • The seismic response characteristics of a port structure were investigated by the earthquake analyses of the structure subjected to high-, low-frequency component, and Uljin earthquakes. In the Fluid-Structure-Soil Interaction(FSSI) analysis, the fluid is modeled by the 4-node quadrilateral element which is a modification of a structural plane element, and the port structure and foundation is modelled by the plane strain element. Since the present method directly models the fluid-structure-soil interaction system using finite element method, it can be easily applied to the dynamic analysis of a 2-D fluid-port-soil system with complex geometry. The results of the seismic coefficient. added mass, and FSSI methods are compared. The results showed that the earthquake with high frequency components more affects the seismic response of the structure than that of low frequency components.

Seismic Response Prediction Method of Cabinet Structures in a Nuclear Power Plant Using Vibration Tests (진동시험을 이용한 원자력발전소 캐비닛 구조의 지진응답예측기법)

  • Koo, Ki-Young;Cui, Jintao;Cho, Sung-Gook;Kim, Doo-Kie
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.5
    • /
    • pp.57-63
    • /
    • 2008
  • This paper presents a seismic response prediction method using vibration tests of cabinet-type electrical equipment installed in a nuclear power plant. The proposed method consists of three steps: 1) identification of earthquake-equivalent forces based on lumped-mass system idealization, 2) identification of a state-space-equation model relating input-output measurements obtained from the vibration tests, 3) seismic prediction using the identified earthquake-equivalent forces and the identified state-space-equation. The proposed method is advantageous compared to other methods based on FEM (finite element method) model update, since the proposed method is not influenced by FEM modeling errors. Through a series of numerical verifications on a frame model and 3-dimensional shell model, it was found that the proposed method could be used to accurately predict the seismic responses, even under considerable measurement noise conditions. Experimental validation is needed for further study.

Seismic Response Estimation and System Identification of Test Steel Structure Using Approximate Nonlinear Filter (비선형 근사필터에 강구조시험체의 지진응답추정 및 동특성식별)

  • 배기환;김두영
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.67-72
    • /
    • 2001
  • 대상으로 하는 시스템의 입출력신호에 근거하여, 시스템의 수학적 모델을 결정하는 것을 총칭하여 시스템식별이라 한다. 본 논문에서는 지진응답 관측치를 입출력신호로 하여 조건부대치를 최적치로 판단하는 비선형근사필터법을 사용한 건축구조물의 지진응답추정 및 파라미터식별에 관하여 논한다. 비선형근사필터법에 의한 건축구조물식별의 유효성의 적용성을 판단하기 위해, 진동대를 사용하여 강구조시험체의 진동실험을 행하고 결과적으로 얻어진 시험체의 수학적 모델에 대한 지진응답 수치해석결과와 진동실험에서의 관측기록을 비교하여 본 식별법의 타당성을 보인다.

  • PDF

Dynamic Response of Seismically Isolated High-Story Buildings according to Earthquake Records (지진기록 사용에 따른 고층 면진건물의 동적 응답)

  • Lee, Hyun-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.643-651
    • /
    • 2008
  • The purpose of this study is to evaluate seismic capacity of seismically isolated building according to the earthquake motion record selection method. To analyze the seismic behavior, 20-story building is designed, which has base isolation system. The using earthquake motion record were selected by two categories. The one is a proposed earthquake record according to soil type and response spectrum shape, and the other is a well known earthquake events such as El Centro (1940). The time history analysis results of base isolation buildings be induced difference results according to each ground motion records. Therefore detailed guidelines for the ground motion records selection method must be prepared. And the response of isolation story displacement and shear force show good seismic performance in consideration of the proposed earthquake records.

Analysis of Seismic Response Coefficient by Fundamental Period using Geographic Information System (GIS를 이용한 고유주기에 따른 지진응답계수 분석)

  • Seo, Eun-Su;Choi, Se-Hyu
    • Spatial Information Research
    • /
    • v.20 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Response of buildings under seismic load is different according to fundamental period. It is provided in Korean Building Code(KBC2009) seismic response coefficient by fundamental period for seismic design of buildings. Recently, many researchers have studied on fundamental period and seismic response coefficient. However, studies on seismic design using Geographic Information System(GIS) are not sufficient. Therefore, this paper has analyzed on seismic response coefficient of buildings using ArcGIS. This paper can be evaluated efficiently for seismic analysis of structures. And this study will be used as basics of a reasonable seismic design using Geographic Information Systems(GIS).

Influence of Building Base-Isolation on Seismic Response of Submerged Internal Systems (건물기초의 절연이 내부수중구조물의 지진응답에 미치는 영향)

  • 신태명
    • Computational Structural Engineering
    • /
    • v.9 no.3
    • /
    • pp.125-134
    • /
    • 1996
  • The base-isolation of building, as appeared in many studies, has shown remarkable performance in seismic response attenuation of the internal system as well as the building structure itself. But for the case that the internal system is submerged and hence subject to a considerable hydrodynamic effect, the seismic response of the system due to the base-isolation of building can be greater than the case that they are in air. This paper presents the dynamic analysis of a submerged internal system on base-isolated building to show such an example. The results show that an additional treatment is required to reduce the adverse effects on the seismic response of such a system when the building is base-isolated, and that the system response can be reduced to some extent by an appropriate control of fluid gap between the system and the building structure.

  • PDF

Estimation of Site Effects at Hongsung Based on 2-Dimensional Basin Modeling within Spatial Geotechnical Information System (공간 지반 정보 시스템을 활용한 2차원 분지 모델링 기반의 홍성 지역 부지 효과 평가)

  • Sun, Chang-Guk;Choo, Yun-Sik;Chung, Choong-Ki
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.253-256
    • /
    • 2008
  • 지하 토사 조건 및 지질 구조는 지진 시 지반 운동의 증폭에 관련된 부지 효과에 매우 큰 영향을 미친다. 본 연구에서는 국내 홍성 지역을 대상으로 시추 조사와 현장 탄성파 시험을 포함한 현장 조사 및 지표 부근지질 정보를 획득하기 위한 부지 답사를 통해 부지 효과를 확인하였다. 홍성 지역은 1978년 계기 지진이 발생한 지역으로서 기반암 상부에 최대 약 50 m 두께의 풍화대 지층이 분포한다. 연구 대상 지역의 공간 지층 구조를 효율적으로 확인하기 위하여 지리정보시스템(GIS) 기법 기반의 지반 정보 시스템(GTIS)의 구축하였으며, 홍성 지역은 분지는 얕고 넓은 형상임을 확인하였다. 홍성 지역의 부지 지진 응답을 평가하기 위하여 대표 단면에 대한 2차원 유한 요소 해석을 수행하였다. 도출된 지진 응답으로부터 지반 운동이 기반암 상부 토사층을 통해 전단파가 전파되면서 증폭되고 분지 형상에 따른 전단파의 상호 작용으로 생성된 표면파로 인해 분지 경계 부근 진동 지속 시간이 증가됨을 확인하였다. 뿐만 아니라, 분지 내의 선정된 토사 부지들에 대해서 추가적인 1차원 유한 요소 지진 응답 해석을 수행하였으며, 본 연구 대상 분지가 매우 얕고 넓음에 따라 분지 경계 부근을 제외하고는 분지 내 대부분의 위치에서 2차원 지진 응답과 유사한 결과를 보였다.

  • PDF

Characteristics of Earthquake Responses of a Rectangular Liquid Storage Tanks Subjected to Bi-directional Horizontal Ground Motions (수평 양방향 지반운동이 작용하는 직사각형 액체저장탱크의 지진응답 특성)

  • Lee, Jin Ho;Lee, Se Hyeok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.1
    • /
    • pp.45-53
    • /
    • 2020
  • Analytical and experimental studies show that the dynamic behavior of liquid storage tanks is significantly influenced by the fluid-structure interaction (FSI). The effects of FSI must be rigorously considered for accurate earthquake analysis and seismic design of liquid storage tanks. In this study, a dynamic analysis of a rectangular liquid storage tank subjected to bi-directional earthquake ground motions is performed and its dynamic characteristics are examined, with the effects of FSI rigorously considered. Hydrodynamic pressure is evaluated using the finite-element approach with acoustic elements and applied to the structure. The responses of the rectangular tank subjected to bi-directional earthquake ground motions are thus obtained. It can be observed that the incident angle of bi-directional horizontal ground motions has significant effects on the dynamic responses of the considered system. Therefore, the characteristics of the system must be considered in its seismic design and performance evaluation.

Nonlinear Effects of a Soft Soil Layer on the Horizontal Seismic Responses of Buildings (건물의 수평방향 내진거동에 미치는 연약지반의 비선형 영향)

  • 김용석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.23-31
    • /
    • 2001
  • 지반 위에 세워진 구조물의 지진응답해석시 지반-구조물 상호작용 영향은 지반으 선형특성을 고려하여 간주되었는데 최근 연구결과에 의하면 구조물 지진해석에서 연약지반의 비선형 특성이 중요한 요소로서 인식되었다. 하지만 지반-구조물계의 복잡한 비선형 특성 때문에 내진설계 기준에서 비선형 지반특성을 고려하기에는 아직도 어려움이 많다. 이 논문에서는 UBC 지반종류 $S_{D}$ 지반 위에 놓인 중규모의 얕은 온통기초와 묻힌 온통기초위에 세워진 건물에 대한 단자유도계 선형 지진해석을 연약지반의 비선형성을 고려하여 최대가속도가 0.17g 과 0.36g 인 Taft E-W 및 El Centro N-S 지진기록을 사용하여 수행하였다. 비선형 지진해석을 결과를 선형해석 결과와 비교하였을 때, 비선형 응답스펙트럼의 최대가속도가 지반의 비선형성 때문에 상당히 줄어드는 것으로 나타나 지반의 비선형성을 고려한 더효율적인 내진설계의 가능성을 보여준다.

  • PDF

KALIMER원자로건물 지진해석 모델링 및 지진응답해석

  • Yoo, Bong;Lee, Jae-Han;Koo, Kyung-Hoe;Lee, Hyeong-Yeon;Choi, In-Gil
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.903-908
    • /
    • 1998
  • KALIMER 원자로 건물에 대하여 3차원 쉘요소 모델과 단순 빔모델을 작성하고 고유진동수 해석을 수행하였다. 두 모델의 1차 수평방향 고유진동수는 대체로 일치하였다. 단순 빔모델에 대해 원자로건물의 회전 관성모멘트를 해석에 반영한 경우 3차원 모델에는 없는 회전모드가 발생되었다. 지진응답해석은 1940 EL Centro와 인공지진에 대하여 수행하였으며, 두 결과는 면진구조물의 경우 비면진구조물과 비교하여 응답가속도가 크게 줄고, 상대변위가 증가하는 경향을 보였다.

  • PDF