• Title/Summary/Keyword: 지진 감지

Search Result 66, Processing Time 0.025 seconds

Evaluation of Low-cost MEMS Acceleration Sensors to Detect Earthquakes

  • Lee, Jangsoo;Kwon, Young-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.5
    • /
    • pp.73-79
    • /
    • 2020
  • As the number of earthquakes gradually increases on the Korean Peninsula, much research has been actively conducted to detect earthquakes quickly and accurately. Because traditional seismic stations are expensive to install and operate, recent research is currently being conducted to detect earthquakes using low-cost MEMS sensors. In this article, we evaluate how a low-cost MEMS acceleration sensor installed in a smartphone can be used to detect earthquakes. To this end, we installed about 280 smartphones at various locations in Korea to collect acceleration data and then assessed the installed sensors' noise floor through PSD calculation. The noise floor computed from PSD determines the magnitude of the earthquake that the installed MEMS acceleration sensors can detect. For the last few months of real operation, we collected acceleration data from 200 smartphones among 280 installed smartphones and then computed their PSDs. Based on our experiments, the MEMS acceleration sensor installed in the smartphone is capable of observing and detecting earthquakes with a magnitude 3.5 or more occurring within 10km from an epic center. During the last several months of operation, the smartphone acceleration sensor recorded an earthquake of magnitude 3.5 in Miryang on December 30, 2019, and it was confirmed as an earthquake using STA/LTA which is a simple earthquake detection algorithm. The earthquake detection system using MEMS acceleration sensors is expected to be able to detect increasing earthquakes more quickly and accurately.

A Study on a Seismic Detection Technology for High-speed Railway Considering Site Response Characteristics (성토 구간 지반 응답을 고려한 열차 내 지진 감지 기술 개발 연구)

  • Yoo, Mintaek;Moon, Jae Sang;Park, Byoungsun;Yoo, Byoung Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.10
    • /
    • pp.41-56
    • /
    • 2020
  • For the rapid and accurate warning, the system requires not only the sufficient number of seismometers but also the appropriate detection technique of sensor data. Instead of installing new seismometers, on-board accelerometers of the train could be utilized as alternatives. However, the data from on-board accelerometers includes train vibrations and the response of embankment site by earthquake, which are different from earthquakes measured from the seismometer. This study suggests signal analysis technique to detect earthquake from the on-board accelerometer data. The virtual on-board accelerometer data including the response of embankment site, obtained from site response analysis method, has been constructed. The constructed data has been analyzed using short time Fourier transform (STFT) and wavelet transform (WT). STFT method provides better performance to detect long-period earthquake whereas WT method is more available to detect short-period earthquake.

Development of Seismic Monitoring System for Natural Gas Governor Station and It's Field Application to Minimize Earthquake Damage (지진 피해 최소화를 위한 지진 감지 시스템 개발 및 현장적용 연구)

  • Yoo H.R.;Park S.S.;Park D.J.;Koo S.J.;Cho S.H.;Rho Y.W.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.19-25
    • /
    • 2000
  • In order to prevent secondary disaster such as gas explosion which comes after a devastating magnitude earthquake, the seismic monitoring and transmission system for natural gas governor station was developed. To measure ground motions precisely and operate the seismic monitoring system efficiently, the position and method of accelerometer installation were recommended by the analysis of ground noise patterns of governor station. For making a decision on prompt shut-off of gas supplies in the event of a great earthquake, the real-time calculation algorithm of PGA(Peak Ground Acceleration) and SI(Spectrum Intensity) were developed and it has been implemented in the seismic monitoring and transmission system.

  • PDF

국내외 지진발생 현황과 국내원전의 안전성 평가

  • 김영식
    • Nuclear industry
    • /
    • v.15 no.7 s.149
    • /
    • pp.56-59
    • /
    • 1995
  • 국내 원전은 내진성 확보를 위해 부지의 선정단계에서는 원전의 예상입지를 중심으로 320km 내의 지진특성과 과거지진기록을 면밀히 분석$\cdot$반영하고, 부지중심으로 반경 8km 내에 대해서는 정밀지질조사를 실시하여 단층대나 연약지반 등 지진발생 가능지역은 제외시키고 있으며, 구조물의 설계와 설치시에는 과거의 지진발생기록을 근거로 하여, 발전소 인근지역에서 발생이 가능한 최대 지진과 부지의 지반특성, 그리고 구조물의 하중 등을 복합적으로 고려하여 내진설계하고 있다. 가동중에는 각종 자동지진감시계통이 지진발생 여부를 지속적으로 계측한 후에, 설계지진값의 절반인 지반가속도 0.1g 이상의 지진을 감지하면 자동경보장치를 작동시켜 즉각 운전이 정지되도록 설계되어 있다.

  • PDF

A Study on the Possibility of the Earthquake Detection based on Telluric Current Monitoring (지전류 모니터링 기반 지진 감지 가능성 연구)

  • Noh, Myounggun;Lee, Heuisoon;Ahn, Taegyu;Jun, Seokang;Chung, Hojoon
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.3
    • /
    • pp.107-115
    • /
    • 2019
  • Recently, since earthquakes have happened frequently in Gyeongju and Pohang areas in Korea, the earthquake detection research gets lots of attention. Geophysical monitoring data have been changed during the earthquake activity because the huge amount of energy is accumulated. The change of telluric current can be predicted by both of piezoelectric and electrokinetic effects before or during the earthquake occurrence, and if the change value exceeds the conventional telluric current noise, we can measure changes in the electric field associated with earthquakes. In this study, we have self-developed and verified the system that can monitor the telluric current. In order to verify our telluric current monitoring system, we installed lines of 40 m (E-W direction) and 28 m (N-S direction) on the site in Pohang. The telluric currents were sampled at 1 kHz for about a month. We have compared and analyzed the data of earthquake signals and electrical noises based on the earthquakes that occurred during the monitoring period. We have monitored if there were significant signals related to the earthquake on measured time series data. Through this study, we will suggest the direction of continuous research in the future.

Part of Information and Communication by occurrence of the earthquake (지진이 발생했을 때의 정보통신의 역할)

  • Kim, Jong-Yun;Shin, Hyun-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.1171-1178
    • /
    • 2005
  • Those days, not only Many peoples are killed and the wounded by effective of earthquake sea wave in Indonesia, but also our country effected by earthquake in adjoining sea to japan. At this point, preparation to earthquake and the point of quickly communication by happened earthquake. For this reason perceptible observation post are making so quickly communication system to zone by effective range of earthquake, and develope than more quality observation tool, contribute to keep citizens property and life to a minimum by earthquake damaged.

  • PDF

Method of Estimating the Ground-Motion Intensity Measures at a Nearby Site by using the Time-domain Transformation of Site Response (지진파형의 시간영역 부지응답특성 변환을 통한 인접부지의 지진동세기 추정 방법)

  • Yun, Kwan-Hee;Park, Dong-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.219-226
    • /
    • 2010
  • Current earthquake alert notification for immediate post-earthquake procedures for the critical facilities is exclusively dependent on the ground-motion intensity measures observed at the seismic station located within the site. This practice is prune to false notification due to a noise and problems of missing and poor quality records of the seismic station. The credibility of the earthquake alert notification can be enhanced by utilizing the multiple transformed records of the nearby seismic stations at other sites interconnected to the same earthquake monitoring system by a network. The time-domain transformation of the site-response between the seismic stations is implemented by convoluting the nearby records with a pair of forward and inverse FIR filters designed for the site response relative to a seismic basement. The transformed records from the nearby seismic stations can be used to estimate the ground-motion intensity measures missing at the site or to evaluate the data quality along with other various possible applications in the area of geoscience and earthquake engineering.

Part of Information and Communication by occurrence of the earthquake (지진이 발생했을 때의 정보통신의 역할)

  • Kim, Jong-Yun;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.2
    • /
    • pp.95-101
    • /
    • 2006
  • Those days, not only Many peoples are killed and the wounded by effective of earthquake sea wave in Indonesia, but also our country effected by earthquake in adjoining sea to japan. At this point, preparation to earthquake and the point of quickly communication by happened earthquake. For this reason perceptible observation post are making so quickly communication system to zone by effective range of earthquake, and develope than more quality observation tool, contribute to keep citizens property and life to a minimum by earthquake damaged.

  • PDF

A Consideration of Earthquake Simulation Test for Telecommunication Equipment Rack (통신 장치랙 지진모사 실험에 대한 고찰)

  • Kang, Wang-Kyu;Han, Jin-Woo;Woo, Byung-Soo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.296-301
    • /
    • 2007
  • 2007년 1월 20일 20시 56분경 오대산 부근에서 발생한 지진이 제주도를 제외한 전국에서 감지되어 우리 생활에 직접적인 영향을 끼치는 등 더 이상 우리나라도 지진에 안전한 나라가 아니라는 것이 입증되고 있으며, 정부에서도 자연재해대책법에 통신설비에 대한 내진설계 의무화 규정을 포함시켜 현재 시행을 눈앞에 두고 있는 시점에서 통신시설물에 대한 내진성능 평가와 내진대책 수립이 절실히 요구되고 있다. 따라서, 본 논문에서는 지진 발생시에 가장 민감하게 반웅하며 피해가 클 것으로 예상되는 통신 장치랙에 대하여 전력설비의 내진성능 검증에 사용되는 인공 지진파와 미국에서 측정한 실측 지진파를 진동대에 입력, 지진모사 실험을 실시하여 지진시 발생할 수 있는 통신장비의 기능 이상 유무를 확인하고 동적 거동 특성을 분석함으로써 장치랙이 보유한 내진성능을 도출하여 보았다. 이러한 지진모사 실험은 향후 통신 장치랙의 내진성능을 평가하는 기준을 수립하는데 중요한 기초자료로 활용될 것이라 판단된다.

  • PDF

Effect of Loading Rate on Self-stress Sensing Capacity of the Smart UHPC (하중 속도가 Smart UHPC의 자가 응력 감지 성능에 미치는 영향)

  • Lee, Seon Yeol;Kim, Min Kyoung;Kim, Dong Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.81-88
    • /
    • 2021
  • Structural health monitoring (SHM) systems have attracted considerable interest owing to the frequent earthquakes over the last decade. Smart concrete is a technology that can analyze the state of structures based on their electro-mechanical behavior. On the other hand, most research on the self-sensing response of smart concrete generally investigated the electro-mechanical behavior of smart concrete under a static loading rate, even though the loading rate under an earthquake would be much faster than the static rate. Thus, this study evaluated the electro-mechanical behavior of smart ultra-high-performance concrete (S-UHPC) at three different loading rates (1, 4, and 8 mm/min) using a Universal Testing Machine (UTM). The stress-sensitive coefficient (SC) at the maximum compressive strength of S-UHPC was -0.140 %/MPa based on a loading rate of 1 mm/min but decreased by 42.8% and 72.7% as the loading rate was increased to 4 and 8 mm/min, respectively. Although the sensing capability of S-UHPC decreased with increased load speed due to the reduced deformation of conductive materials and increased microcrack, it was available for SHM systems for earthquake detection in structures.