• Title/Summary/Keyword: 지진응답 제어

Search Result 156, Processing Time 0.029 seconds

Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System (스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선)

  • Jung, Hyung-Jo;Jung, Chan-Kuk;Choi, Kang-Min;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.37-46
    • /
    • 2006
  • In this study, the efficacy of the newly developed smart passive control system to improve seismic performance of base isolated building structures is numerically verified. The smart passive control system consists of a magnetorheological (MR) damper and an electromagnetic induction (EMI) part. The damping characteristics of an MR damper can be controlled by the current generated in an EMI part according to the Faraday's law of electromagnetic induction. An EMI part consisting of a permanent magnet and a solenoid coil could substitute a control system including sensors, a controller and an external power supply in a conventional smart control system. The benchmark control problem for a base isolated building presented by the american society of civil engineers is considered for numerical simulation. The control performance of the smart passive control system is compared to that of the conventional smart control system using MR dampers. It is demonstrated from the numerical simulation results that the smart passive control system is useful to improve the seismic performance of base isolated buildings.

Experimental Study of System Identification for Seismic Response of Building Structure (건축구조물의 지진응답제어를 위한 시스템 식별의 실험적 연구)

  • 주석준;박지훈;민경원;홍성목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.4
    • /
    • pp.47-60
    • /
    • 1999
  • The stability and efficiency of structural control systems depend on the accuracy of mathematical model of the system to be controlled. In this study, state equation models of a small scale test structure and an AMD(active mass damper) are obtained separately using OKID(observer/Kalman filter identification) which is a time domain system identification method. The test structure with each floor acceleration as outputs is identified for two inputs - the ground acceleration and the acceleration of the moving mass of AMD relative to the installation floor - individually and the two identified state equation models are integrated into one by model reduction method. The AMD is identified with the motor control signal as an input and the relative acceleration of the moving mass as an output, and it is shown that the identified model has large damping ratio and phase shift. The transfer functions and the time histories reconstructed from the identified models of the test model and the AMD match well with those measured from the experiment.

  • PDF

Optimal Parameter of Tuned Mass Damper for Controlling Seismic Response (지진응답제어를 위한 동조질량감쇠기의 최적설계지수(단단한 지반))

  • Lee, Joung-Woo;Woo, Sung-Sik;Lee, Sang-Hyun;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.97-100
    • /
    • 2006
  • This study performed numerical analysis for obtaining optimal frequency and damping ratio of tuned mass damper (TMD) using 20 seismic loads measured at rock site. The structures of $1{\sim}2$ second natural period were considered, and optimal frequency and damping ratio were estimated for different mass ratio in terms of displacement and absolute acceleration response control. Numerical results showed that the values of the optimal parameters were different those from previous study by Hartog.

  • PDF

A Study on Vibration Control of Port Structure using Immunized PID Controller (Immunized PID 제어기를 이용한 항만 구조물의 진동제어에 관한 연구)

  • Lee, Young-Jin;Lee, Kwon-Soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.399-404
    • /
    • 2005
  • In this paper, An immunized PID(I-PID) controller based on cell mediated immune response is proposed to improve the control performance of the controller with PID scheme. And it is applied to the vibration of the building structure in the port with active damper systems. The immune system of organism in the real body regulates the antibody and T-cells to protect the attack from the foreign materials which are virus, germ cell, and other antigens. It has similar characteristics that are the adaptation and robustness to overcome disturbances and to control the plant of engineering application. At firstly, we build a model of the T-cell regulated immune response mechanism. We have also designed an I-PID controller focusing on the T-cell regulated immune response of biological immune system. Finally, we show that some computer simulations of the vibraton control for the building structure system with wind force excitation. These results for the proposed method also show that is has performance than other conventional controller design method.

  • PDF

Multi-objective Optimal Design using Genetic Algorithm for Semi-active Fuzzy Control of Adjacent Buildings (인접건물의 준능동 퍼지제어를 위한 유전자알고리즘 기반 다목적 최적설계)

  • Kim, Hyun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.219-224
    • /
    • 2016
  • The vibration control performance of a semi-active damper connected to adjacent buildings subjected to seismic loads was investigated. The MR damper was used as a semi-active control device. A fuzzy logic control algorithm was used for effective control of the adjacent buildings connected to the MR damper. In the buildings control coupled with a MR damper, the response reduction of one building results in an increase in the response in another building. Because of these conflict characteristics, multi-objective optimization is required. Therefore, a fuzzy logic control algorithm for the control of a MR damper was optimized using a multi-objective genetic algorithm. Based on numerical analyses, the semi-active fuzzy control of MR damper for adjacent coupled buildings can provide good control performance.

Experimental Study on the MR-Toggle Brace System for Vibration Control (지진응답 제어를 위한 MR-토글 가새 시스템의 실험적 연구)

  • Min Kyung-Won;Lee Myoung-Kyu;Kang Sang-Hoon;Lee Sang-Hyun;Hwang Jae-Seung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.644-651
    • /
    • 2005
  • The purpose of this paper is to compare the control effect of toggle brace system having amplifying displacement mechanism with that of conventional brace system when the identical MR damper is applied to each system. The force-displacement and lone-velocity relationships of MR damper are obtained using harmonic load test and the analytical model for MR damper is presented. White noise excitation tests of a single degree of freedom system with MR-toggle brace system and MR-chevron system are conducted and the transfer functions of the systems are compared. Test results show that the control effect of the toggle system is superior to that of the conventional brace system.

  • PDF

Method for checking Missed eigenvalues of Eigenvalue Problem Considering Damping Matrix (감쇠행렬을 고려한 고유치문제의 누락된 고유치 검사 기법)

  • 정형조;김병완;이인원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.47-56
    • /
    • 2000
  • 지반-구조물 상호작용 시스템 구조물의 진동제어 시스템 복합재료 구조물과 같은 비비례 감쇠 구조물의 경우 정확한 동적응답을 얻기 위해서는 감쇠행렬을 고려한 고유치 문제를 계산하는 것이 필수적이다 그러나 대부분의 고유치 해법에서는 구하고자 하는 고유치 중 일부를 누락시킬 수 있기 때문에 어떤 고유치 해법이 실제문제에 응용 가능한 방법이 되기 위해서는 누락된 고유치의 존재 여부를 검사하는 기법을 포함하고 있어야만 한다. 비감쇠나 비례감쇠 시스템의 경우에는 널리 알려진 Sturm 수열성질을 이용하여 누락된 고유치를 쉽게 검사할 수 있는 반면에 비비례 감쇠 시스템의 경우에는 널리 알려진 Sturm 수열 성질을 이용하여 누락된 고유치를 쉽게 검사할 수 있는 반면에 비비례 감쇠 시스템의 경우에는 아직까지 검사 기법이 개발되어 있지않다 본 논문에서는 편각의 원리를 이용하여 감쇠행렬을 고려한 고유치 문제의 누락된 고유치의 존재여부를 검사하는 기법을 제안하였다 제안방법의 효용성을 검증하기 위하여 두가지 수치예제를 고려하였다.

  • PDF

Control Strategy for Seismic Responses of Cable-Stayed Bridges Using MR Fluid Dampers (MR 유체 감쇠기률 이용한 사장교의 지진응답 제어 기법)

  • Jung, Hyung_-Jo;Moon, Yeong-Jong;Ko, Man-Gi;Lee, In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.149-156
    • /
    • 2002
  • This paper examines the ASCE first generation benchmark problem for a seismically excited cable-stayed bridge, and proposes a new semi-active control strategy focusing on inclusion of effects of control- structure interaction. In this study, magnetorheological (MR) fluid dampers, which belong to the class of controllable fluid dampers, are proposed as the supplemental damping devices, and a clipped-optimal control algorithm, shown to perform well in previous studies involving MR fluid dampers, is employed. The dynamic model for MR fluid dampers is considered as a modified Bouc-Wen model, which is obtained from data based on experimental results for large-scale dampers. Numerical results show that the performance of the proposed semi-active control strategy using MR fluid dampers is quite effective.

  • PDF

Comparative Study of Tuned Mass Damper and Tuned Liquid Column Damper for Response Control of Building structures (동조질량감쇠기와 동조액체기둥감쇠기의 건물응답의 제어성능 비교연구)

  • 김홍진;김형섭;민경원;오정근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.427-434
    • /
    • 2003
  • In this study, the control performances of Tuned Mass Damper (TMD) and Tuned Liquid Column Damper (TLCD) are evaluated and compared for seismically excited structures. Results show that TLCD is more effective than TMD for interstory drift control while TLCD is as effective as TMD for acceleration control. In special, it is shown that interstory drifts are maximally controlled in lower floors and accelerations are reduced most in upper floors. This indicates that TLCD is an effective controller for earthquake-induced structures in terms of structural safety as well as serviceability.

  • PDF

Seismic Response Control of Dome Structure Subjected to Multi-Support Earthquake Excitation (다중지점 지진하중을 받는 돔 구조물의 지진응답 제어)

  • Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.4
    • /
    • pp.89-96
    • /
    • 2014
  • Spatial structures as like dome structure have the different dynamic characteristics from general rahmen structures. Therefore, it is necessary to accurately analyze dynamic characteristics and effectively control of seismic response of spatial structure subjected to multi-supported excitation. In this study, star dome structure that is subjected to multi-supported excitation was used as an example spatial structure. The response of the star dome structure under multiple support excitation are analyzed by means of the pseudo excitation method. Pseudo excitation method shows that the structural response is divided into two parts, ground displacement and structural dynamic response due to ground motion excitation. And the application of passive tuned mass damper(TMD) to seismic response control of star dome structures has been investigated. From this numerical analysis, it is shown that the seismic response of spatial structure under multiple support seismic excitation are different from those of spatial structure under unique excitation. And it is reasonable to install TMD to the dominant points of each mode. And it is found that the passive TMD could effectively reduce the seismic responses of dome structure subjected to multi-supported excitation.