Estimation of Seismic Fragility for Busan and Incheon Harbor Quay Walls (부산 및 인천항만 안벽구조물의 지진취약도 예측)

  • Kim, Young Jin;Kim, Dong Hyawn;Lee, Gee Nam;Park, Woo Sun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.6
    • /
    • pp.412-421
    • /
    • 2013
  • Nowadays, small and medium-sized earthquakes occur frequently in the west coast of Korea. The earthquake induced damages on the harbor structure such as quay wall possibly make a severe impact on national economy. Therefore, not only a seismic design for the structures but warning system for seismic damage right after the occurrence of earthquake should be developed. In this study, seismic fragility analysis was performed to be given to earthquake damage prediction system for quay wall structures in Busan and Incheon harbor. Four types of structures such as pier-type, caisson type, counterfort type, block-type were analyzed and fragility curves of functional performance level and collapse prevention level based on displacement criteria were found. Regression analyses by using the results of the two ports were done for possible use in other port structures.

Seismic P-$\Delta$ Effects of Slender RC Columns in Earthquake Analysis (지진하중을 받는 철근콘크리트 장주의 P-$\Delta$ 효과)

  • Kwak, Hyo-Gyoung;Kim, Jin-Kook
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.4 s.74
    • /
    • pp.375-387
    • /
    • 2006
  • Different from the previous studies which investigated seismic P-$\Delta$ effect in slender columns though comparison of response spectra according to stability coefficients obtained from the analyses based on the assumed moment-curvature relationship, the axial force and P-$\Delta$ effect in RC columns are investigated on the basis of the layered section method which can effectively consider the changes of stiffness and yield strength due to the application of axial force in RC members. Practical ranges of slenderness and stability coefficient are assumed, and sixty sets of horizontal/vertical earthquake inputs are used in the analysis. From the parametric study, it is noted that the maximum deformation of the slender RC column is hardly affected by P-$\Delta$ effect or vortical earthquake but dominantly affected by the applied axial force. Therefore, it can be concluded that no additional consideration for the P-$\Delta$ effect and vortical earthquake is required in the seismic design of a slender RC column if the axial force effect is taken into account in the analysis and design procedures.

An Experimental Study of the Long-term Creep characteristic of High Damping Rubber Bearings (고감쇠 고무받침의 장기 크리프 특성에 대한 실험적 연구)

  • Oh, Ju;Park, Jin-Young;Park, Kun-Nok;Kim, See-Dong;Park, Sung-Kyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Isolated structures use devices such as high damping rubber bearings (HDRB) in order to dramatically reduce the seismic forces transmitted from the substructure to the superstructure. The laminated rubber bearing is the most important structural member of a seismic isolation system. The basic characteristics of rubber bearings have been confirmed through compression tests, compressive shearing tests and creep tests. This paper presents the results and analysis of a 1000hr, ongoing creep test conducted at 7.5MPa, 8.37MPa in our laboratory. The long-term behavior of bridge bearings, such as high-damping rubber bearings, will be discovered through a compression creep test subjected to actual environmental conditions. These tests indicated that the maximum creep deformation is about $0.3{\sim}1.92%$ of total rubber thickness.

Earthquake Simulation Tests of A 1:5 Scale Gravity Load Designed 3-Story Reinforced Concrete Frame (중력하중 설계된 1:5 축소 3층 철근콘크리트 골조의 지진모의실험)

  • 이한선;우성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.241-252
    • /
    • 1998
  • The objective of the research stated herein is to observe the actual responses of a low-rise nonseismic moment-resisting reinforced concrete frame subjected to varied levels of earthquake ground motions. First, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used and the model was manufactured according to the similitude law. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelations (PGAs) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The lateral accelerations and displacements at each story and local deformations at the critical reginos of the structure were measured. The base shear was measured by using self-made load cells. Before and after each earthquake simulation test, free vibration tests were performed to find the change in the natural period and damping ratio of the model. The test data on the global and local behaviors are interpreted. The model showed the linear elastic behavior under the Taft N21E motion with the PGA if 0.12g, which represents the design earthquake in Korea. The maximum base shear was 1.8tf, approximately 4.7 times the design base shear. The model revealed fairly good resistance to the higher level of earthquake simulation tests. The main components of its resistance to the high level of earthquakes appeared to be 1) the high overstrength, 2) the elongation of the fundamental period, and 3) the minor energy dissipation by inelastic deformations. The drifts of the model under these tests were approximately within the allowable limit.

Seismic Evaluation for Strainer in the Primary Cooling System (일차 냉각계통 스트레이너에 대한 내진 건전성 평가)

  • 정철섭
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.3
    • /
    • pp.295-304
    • /
    • 2000
  • To evaluate the structural integrity for the strainer under seismic loading the seismic analysis and design were performed for T-type strainer in accordance with ASME, Section Ⅲ, Class 3(ND). Since there are no specified design requirements for the strainer in ASME Code, the strainer body was analysed according to ND-3500, valve design. Flanged joints connected with PCS piping were designed according to ND-3658.3. And the criteria for the cover flange was governed by the Appendix XI. Both a frequency analysis and an equivalent static seismic analysis of the strainer were carried out using the finite element computer program, ANSYS. The frequency analysis results show the fundamental natural frequency is greater than 33Hz, thus justifying the use of the equivalent static analysis through which membrane and bending stresses are obtained in the critical points near the branch connection area. The results of the seismic evaluation fully satisfied with the structural acceptance criteria of the ASME Code. Accordingly the structural integrity on the strainer body and flanges were proved.

  • PDF

Estimation of Seismic Responses of Hualien LSST Model By the Substructure Method of Soil-Structure Inraction Analysis (Hualien 대형지진시험 모델의 지진응답해석)

  • 조양희;박형기
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.59-68
    • /
    • 1997
  • Seismic responses of the Hualien large scale seismic test model on a layered soil site are estimated for three recorded earthquakes with different level of peak acceleration using two different approaches of soil-structure interaction analysis. The analysis results are then compared and evaluated with the recorded. The method adopted for the analysis is based on substructuring method using a lumped parameter model in both the frequency and time domain. The study results indicate that the proposed method can reasonably estimate the earthquake responses of a soil-structure interaction system of r engineering purposes if the techniques of defining input motion and modeling of the backfilled soil are prudently selected.

  • PDF

The Evaluation of Seismic Performance for Concrete-filled Steel Piers (콘크리트 충전 강교각의 내진 성능 평가)

  • 정지만;장승필;인성빈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.5
    • /
    • pp.53-58
    • /
    • 2002
  • A recent development, a concrete-filled steel(CFS) pier is an alternative to a reinforced concrete bridge pier in an urban area, because of its fast construction and excellent ductility against earthquakes. The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

Simultaneous Optimum Design of Hybrid Structural Control System (복합구조제어시스템의 동시최적설계)

  • 박관순;고현무
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.5
    • /
    • pp.37-43
    • /
    • 2002
  • In this paper, an integrated optimum design method for hybrid structural control system is studied. Not only the distribution and the capacity of passive devices but also those of active devices, and the controllers are treated as design variables in the proposed approach. Multi-objective optimization problem is formulated by using the preference function, which is newly defined in this study. Genetic algorithm is adopted as a numerical searching technique in order to simultaneously find the optimum solutions. The validity of the proposed method is verified through the example designs and the numerical simulations of an earthquake excited multi-degrees-of-freedom structure.

Seismic Performance Evaluation of Wind-Designed High-rise Steel Diagrid Frames (내풍설계된 초고층 철골대각가새골조의 내진성능평가)

  • Kim, Seon-Woong;Kim, Jong-Ho;Kim, Tae-Jin;Kang, Dae-Eon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.14-17
    • /
    • 2011
  • 본 논문에서는 강풍대이면서 중/약진대에 위치하는 초고층건물에 내습할 수 있는 잠재적 지진에 대하여 다양한 지반조건에 따른 응답스펙트럼해석과 내진성능평가를 수행하였다. 국내와 같이 강풍대에 위치하면서 중약진대에 속하는 지진환경하에서 세장비 5.2이상의 초고층 철골대각가새골조는 10%/50년 재현주기 지진동에 대해서는 탄성저항가능성을 나타내었고 세장비 6.9이상의 초고층 철골대각가새골조는 2%/50년 재현주기 지진동에 대해서도 탄성적으로 저항할 수 있음을 보여주었다.

  • PDF

An Establishment of Technical Regulation for Seismic Design on the Telecommunication Installations (통신설비 내진시설 기술기준(안) 수립)

  • Lee, Sang-Mu;Jo, Pyeong-Dong
    • Electronics and Telecommunications Trends
    • /
    • v.23 no.1 s.109
    • /
    • pp.163-169
    • /
    • 2008
  • 최근 빈번한 국제적 지진 발생과 더불어 우리나라에 있어서도 경각심이 조성되어 지진 재해에 대한 법적 대응이 강화되고 있다. 지진 발생시 통신서비스의 긴박성을 인식하여 자연재해대책법상 전기통신기본법에 의한 통신설비가 내진대책 시설의 부류로 지난 2007년 1월 개정 당시 추가되었다. 이에 따라 세부 설치 기준에 대하여는 관계 부처 소관의 해당 법령에서 수립하도록 하고 있다. 이러한 배경 하에 본 논문에서는 통신설비 시설상에 적용하여야 할 내진설계 및 검증을 위한 법적 규격인 기술기준안 수립에 토대가 되는 세부 연구 내용을 소개한다. 먼저 통신설비의 적용 대상 범위를 제시하고 각 설비 그룹 및 분류별로 적용될 내진설계 및 검증 방식을 설명한다. 여기에서 활용할 외국 규격기술에 대하여 언급한다. 아울러 지진 현상과 관련하여 실제 시설상의 여러 가지 고려 대상이 되는 요소들에 대한 기준 요구내용을 제시하였다.