• Title/Summary/Keyword: 지진대응

Search Result 225, Processing Time 0.028 seconds

Comparative Study on the Attenuation of P and S Waves in the Crust of the Southeastern Korea (한국 남동부 지각의 P파와 5파 감쇠구조 비교연구)

  • Chung, Tae-Woong
    • Journal of the Korean earth science society
    • /
    • v.22 no.2
    • /
    • pp.112-119
    • /
    • 2001
  • The Yangsan fault in the southeastern Korea has been receiving increasing attention in its seismic activity. In this fault region, by using the extended coda-normalization method for 707 seismograms of local earthquakes, were obtained 0.009f$^{-1.05}$ and 0.004f$^{-0.70}$ for fitting values of Q$_p^{-1}$ and Q$_s^{-1}$, respectively. These results indicate that Q$_p^{-1}$ and Q$_s^{-1}$ in the southeastern Korea is the lowest level in the world although the exponent values agree well with those in the other areas. The low Q-1 is not related to the movement of the Yangsan fault but to the tectonically inactive status like a shield area.

  • PDF

Robustness Estimation for Power and Water Supply Network : in the Context of Failure Propagation (피해파급에 대한 고찰을 통한 전력 및 상수도 네트워크의 강건성 예측)

  • Lee, Seulbi;Park, Moonseo;Lee, Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.3
    • /
    • pp.33-42
    • /
    • 2018
  • In the aftermath of an earthquake, seismic-damaged infrastructure systems loss estimation is the first step for the disaster response. However, lifeline systems' ability to supply service can be volatile by external factors such as disturbances of nearby facilities, and not by own physical issue. Thus, this research develops the bayesian model for probabilistic inference on common-cause and cascading failure of seismic-damaged lifeline systems. In addition, the authors present network robustness estimation metrics in the context of failure propagation. In order to quantify the functional loss and observe the effect of the mitigation plan, power and water supply system in Daegu-Gyeongbuk in South Korea is selected as case network. The simulation results show that reduction of cascading failure probability allows withstanding the external disruptions from a perspective of the robustness improvement. This research enhances the comprehensive understanding of how a single failure propagates to whole lifeline system performance and affected region after an earthquake.

A Study on the Present Condition and Countermeasure Plan for the Disaster Protection in Public Library of Korea (한국 공공도서관의 재난대비 실태와 대응방안 연구)

  • Kim, Po-Ok
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.40 no.4
    • /
    • pp.85-110
    • /
    • 2006
  • Recently, there have been a number of news reports on natural disasters, like earthquakes. typhoons, floods and tsunami, all over the world. Korea does not seem to be safe from such disasters or terror threats. As places with high numbers of visitors. libraries need to take preventive measures to be prepared for such disasters and threats. This paper analyzes the current status of emergency measures adopted by 75 public libraries in Seoul. Daejeon and Jeonbuk in Korea. For each library surveyed. the causes of and ways to recover from disasters were reviewed and detailed analyses were carried out in low areas: Implementation of preventive measures disaster management and equipment, status of human resources and assignment of people to disaster recovery, safety courses offered to library users and training methods. In addition, each area was analyzed in regard to possible solutions and ideas for improvement, as well as suggestions to upgrade disaster recovery systems in the future.

Seismic Performance Evaluation for Piloti Structures of MPS Seismic Isolation Device in Response to Earthquakes on the Richter Scale 7.0 - Nonlinear Dynamic Analysis (리히터 규모 7.0의 지진에 대응하는 MPS 면진받침의 필로티 구조물에 대한 내진성능 평가 - 비선형 동적 해석)

  • Cho, Han-Min;Hu, Jong-Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.13-20
    • /
    • 2021
  • Recently, various piloti structures have been constructed in Korea to secure residential and parking spaces. However, these piloti structures have been constructed in the form of protruding columns without walls to secure parking spaces on the first floor. In this form, when an earthquake occurs, the column is relatively easily damaged compared to general structures, and such damage can lead to the collapse of the structure. Therefore, in this study, a study on securing the safety of the piloti structure using the MPS (Multi Performance System) seismic isolation device was conducted. Nonlinear dynamic analysis according to the presence or absence of MPS seismic isolation device was performed on the existing piloti structure, and analysis results were compared and analyzed. Finally, each seismic performance evaluation was performed and the superiority of the MPS seismic isolation device was verified.

Integrated Health Monitoring System for Infra-Structure (도시인프라 구조물 건전성 통합 모니터링 시스템)

  • Ju, Seung-Hwan;Seo, Hee-Suk;Lee, Seung-Hwan;Kim, Min-Soo
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.2
    • /
    • pp.147-155
    • /
    • 2010
  • It often occur to nature disaster that like earthquake, typhoon, etc. around KOREA. A Haiti and Chile also metropolitan area of KOREA occur earthquake. in result, People consider nature disaster. Structures of present age are easily affected by nature disaster. So we are important that warn of dangerous situation as soon as possible. On this study, I introduce Integrated Health Monitoring System for Infra-structure. I develop Structure Health Monitoring System on web-site. Administrator always monitor structure on real-time using internet network. As Administrator using mobile device like PDA, Administrator always monitor structure. As using this system, Damage of nature disaster is minimized and is prevented post damage.

Development of Empirical Fragility Function for High-speed Railway System Using 2004 Niigata Earthquake Case History (2004 니가타 지진 사례 분석을 통한 고속철도 시스템의 지진 취약도 곡선 개발)

  • Yang, Seunghoon;Kwak, Dongyoup
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.111-119
    • /
    • 2019
  • The high-speed railway system is mainly composed of tunnel, bridge, and viaduct to meet the straightness needed for keeping the high speed up to 400 km/s. Seismic fragility for the high-speed railway infrastructure can be assessed as two ways: one way is studying each element of infrastructure analytically or numerically, but it requires lots of research efforts due to wide range of railway system. On the other hand, empirical method can be used to access the fragility of an entire system efficiently, which requires case history data. In this study, we collect the 2004 MW 6.6 Niigata earthquake case history data to develop empirical seismic fragility function for a railway system. Five types of intensity measures (IMs) and damage levels are assigned to all segments of target system for which the unit length is 200 m. From statistical analysis, probability of exceedance for a certain damage level (DL) is calculated as a function of IM. For those probability data points, log-normal CDF is fitted using MLE method, which forms fragility function for each damage level of exceedance. Evaluating fragility functions calculated, we observe that T=3.0 spectral acceleration (SAT3.0) is superior to other IMs, which has lower standard deviation of log-normal CDF and low error of the fit. This indicates that long-period ground motion has more impacts on railway infrastructure system such as tunnel and bridge. It is observed that when SAT3.0 = 0.1 g, P(DL>1) = 2%, and SAT3.0 = 0.2 g, P(DL>1) = 23.9%.

Seismic Performance-Based Design for Breakwater (방파제의 성능기반 내진설계법)

  • Kim, Young-Jun;Park, Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.91-101
    • /
    • 2022
  • The 1995 Kobe earthquake caused a massive damage to the Port of Kobe. Therefore, it was pointed out that it was impossible to design port structures for Level II (Mw 6.5) earthquakes with quasi-static analysis and Allowable Stress Design methods. In Japan and the United States, where earthquakes are frequent, the most advanced design standards for port facilities are introduced and applied, and the existing seismic design standards have been converted to performance-based design. Since 1999, the Korean Port Seismic Design Act has established a definition of necessary facilities and seismic grades through research on facilities that require seismic design and their seismic grades. It has also established a performance-based seismic design method based on experimental verification. In the performance-based seismic design method of the breakwater proposed in this study, the acceleration time history on the surface of the original ground was subjected to a fast Fourier transform, followed by a filter processing that corrected the frequency characteristics corresponding to the maximum allowable displacement with respect to performance level of the breakwater and the filtered spectrum. The horizontal seismic coefficient for the equivalent static analysis considering the displacement was calculated by inversely transforming (i.e., subjected to an inverse fast Fourier transform) into the acceleration time history and obtaining the maximum acceleration value. In addition, experiments and numerical analysis were performed to verify the performance-based seismic design method of breakwaters suitable for domestic earthquake levels.

Characteristics on Volcanoes Monitoring and Disaster System of Japan (일본의 화산감시 및 분화대응 특성)

  • Jang, Eun Suk
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.188-188
    • /
    • 2011
  • 작년 아이슬란드에서의 화산폭발로 발생된 화산재가 대기 중으로 이동하면서 유럽 공항 곳곳의 항공기 수천 편이 운항 중지되기도 하였다. 한반도내의 백두산은 약 1000전(서기 946년~947년 경) 대규모로 분화하였고, 서기 1903년, 소규모 분화한 후, 앞으로 수년~수십 년 사이에 폭발적인 분화를 재개할 가능성이 제기되고 있으며, 백두산 분화 시, 아이슬란드 화산폭발 때보다 훨씬 심각한 피해가 예상되고 있다. 따라서 백두산 화산에 대한 현지 자료의 수집과 꾸준한 모니터링(감시, 관측) 자료의 분석과 재해 예상 범위 및 대응 방안의 모색이 필요한 시점이다. 본 연구에서는 지리적으로 가까이 있으며 108개 활화산의 화산재해 방재에 관하여 꾸준히 활동하고 있는 일본에서의 화산감시 및 분화대응 시스템을 파악하고, 우리나라의 화산재해대책을 수립하기위한 시사점들을 고찰하였다. 화산의 평균적인 분화 간격은 풍수해나 지진 등 다른 재해에 비해 길기 때문에 일본 기상청에서는 과거1만년 이내에 분화한 증거가 있는 화산이 활화산으로서 인정되고 있다. 백두산은 약 1000년 전에 분화한 뒤 최근 분화의 전조현상을 보이고 있으며, 중국과 북한에 인접하여 있으므로 우리나라에 직접적인 피해는 예상되지 않으나, 우리나라에 일본과 같은 활화산이 존재하지 않기 때문에 생소하였던 화산재해란 어떠한 것이며, 향후 잠재적인 분화 가능성을 가지고 있는 백두산폭발로 인한 재해의 종류를 미리 예상하고 준비할 필요가 있다. 일본의 경우 계속적인 감시와 관측을 통한 분화예보, 경보를 발령하고 분화 시 즉각적인 방재정보를 전달, 지역주민들이 빠르게 인지, 주의하도록 화산재해 대책 시스템이 갖추어져 있다. 우리나라는 아직 중국과 북한에 인접한 백두산에 대한 관측 자료가 거의 없고, 연구를 위한 접근 또한 쉽지 않은 상황이다. 분화로 인한 직접적인 영향권에서는 벗어난다할지라도 계절적인 기상장의 영향 및 아직 예측 불가능한 백두산의 잠재적인 폭발규모에 따라 간접적인 영향을 받을 경우에 대비하여야 할 필요성이 있다고 사료된다. 또한 우리나라의 화산재해 방재력을 향상시키기 위하여 백두산 폭발로 인한 재해위험범위를 가시화하고, 분화 시에 대한 구체적인 가상시나리오를 작성하여, 화산재 및 대기오염물질의 확산시뮬레이션, 기후변화에 끼치는 영향 등을 포함하는 화산재해대책을 미리 세워 피해를 저감시킬 수 있는 방재대책을 수립해야 할 것이다.

  • PDF

Applications of Volunteer Fire Fighters against Great Disasters and its Implications (대규모 재난대비를 위한 의용소방대 활용방안과 시사점)

  • Choi, Junho;Choi, Choongik
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.87-94
    • /
    • 2018
  • This study examined the role of volunteer fire fighters in coping with great disasters in terms of community-based disaster management to provide some implications from a qualitative comparative case study between Korea and Japan. Kobe, which suffered from the Great Hanshin-Awaji earthquake in 1995, was the study area. The city experienced an inadequate institutional system and lack of disaster management infrastructure at the time before the disaster. The study indicates that Korea volunteer fire fighters are not prepared sufficiently to tackle great disasters in terms of the supporting system, capacity and role by analyzing improvement plans of Japanese Volunteer Fire Fighters after Great East Japan earthquake in 2011. The results of the case study suggests improvements in the disaster management system to provide cooperation between the central government and local government, core task distribution, and community-based disaster management.

A Study on Japanese Disaster Relevant Regulations and NHK (일본의 재난방송 관련 법규와 NHK에 관한 연구)

  • Lee, Yeon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2019.06a
    • /
    • pp.212-215
    • /
    • 2019
  • 지난 4월4일 고성 산불로 사망자 2명과 부상자 1명, 가옥 500여 채, 삼림 1757ha가 불에 탔다. 강원 산불에 이어 영덕지진 등에서 늑장대응을 보여준 재난방송시스템에는 많은 국민들에게 실망감을 안겨주었다. 재난방송 주관방송사인 KBS는 물론, MBC, SBS의 경우도 재난방송시스템에 관련 된 측면에서 본다면 아직 이웃나라 인 일본에 비해서는 매우 열악한 형편이다. 그럼에도 불구하고 점점 대형화, 다발화 하는 재난발생에 대응하기 위해서는 국가적인 차원에서도 특단의 조치가 필요하다. 미국의 경우는 차세대 재난정보 전달체계인 IPAWS(Integrated Public Alert and Warning System)를 개발해 지상파뿐만 아니라, 케이블TV, SNS 등 다양한 매체를 통해 재난정보를 신속하게 전달하고 있다. 일본도 이와 유사한 재난경보전달시스템인 J-Alert를 개발해 2020년까지는 '재난 약자 제로(Zero)시대'를 목표로 구현하고 있다. 우리나라는 지난 아현동 KT 화재사건에서도 경험했듯이 통신이 먹통이 되는 통신블랙아웃도 경험했다. 따라서 대형재난발생 시는 신속한 재난경보전달시스템이 재난피해를 줄일 수 있는 가장 중요한 생명줄이 될 수 있다. 미국이나 일본의 경우는 재난방송전달시스템을 관련법령으로 제도화 하고 있다. 특히, 일본에는 재난에 관한 모법이라고 할 수 있는 (1)"재해대책기본법"이 있는데, 이는 재해로부터 국토, 국민의 생명과 재산을 보호하기 위한 기본법으로 규정되어 있다. 그 밖에도 (2)방송법 (3)대규모지진대책특별 조치법 (4)국민보호법 (5)소방조직법 (6)수해방지법 등으로 규정하고 있다. 과거 일본도 우리나라와 같이 대형 산불이 잦았으나 요즘은 소형 산불만 발생하는 추세다. 이는 NHK가 보유한 700여 대의 로봇카메라와 전 국토를 샅샅이 감시하는 CCTV 덕택이다. 또한, NHK 보도국의 '기상 재해센터'는 재난에 대비해 40여 명의 전문 인력이 24시간 대응체제를 갖추고 있다. 나아가 NHK는 전국 12개의 거점지역에 헬리콥터 15대를 배치하여 신속하게 취재하고 있다. 이 뿐만 아니라, 46개의 지역방송국을 7개의 거점방송국으로 분할하여, 거점방송국마다 40여명의 카메라맨을 상주시켜 언제든지 재난을 취재할 수 있도록 하고 있다. 세계 각국에서 사용하고 있는 방송 주파수는 공공재(公共材)다. 국제전기통신연합(ITU : International Telecommunication Union)으로부터 주파수를 할당받아 사용하고 있기 때문에 주파수에 관한 사용 권한은 각국의 국민 모두에게 있다. 그러나 효과적인 주파수 활용을 전제로 정부가 일정한 자격을 갖춘 방송사업자에게 일시적으로 주파수 사용권을 위임하고 있다. 따라서 일본 정부도 국가적인 위기나 대형 재난발생으로 국민들의 생명과 재산이 위협받고 있을 때에는 공공재인 주파수를 즉시 재난방송으로 사용할 수 있도록 <재해대책기본법 제6조>와 방송법 제108조에 규정하고 있다.

  • PDF