수치 시뮬레이션을 이용한 수직밀폐형 지열시스템의 채열특성에 관한 연구 (Study on the characteristic of heat exchange for vertical geothermal system using the numerical simulation)

  • 남유진;오진환
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.66-72
    • /
    • 2014
  • Ground source heat pump system can achieve high efficiency of performance by utilizing annually constant underground temperature to provide heat source for space heating and cooling. Generally, the depth of constant-temperature zone under the ground depends on surface heat flux and soil properties. The deeper the ground heat exchanger is installed, the higher the heat exchange rate can be acquired. However, in order to optimally design the system, it is necessary to consider both the installation cost and the system performance. In this study, performance analysis of ground source heat pump system according to the depth has been conducted through the case study.

지중온도회복을 고려한 지열 히트펌프 시스템의 운전방법 검토 (Study on the Operation Method of Ground Source Heat Pump System Considering Recovery of Ground Temperature)

  • 배상무;전재영;권영식;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.24-30
    • /
    • 2020
  • Ground source heat pump (GSHP) systems are actively introduced as cooling and heating conditioning systems of buildings due to annual stable performance and easily maintenance. However, ground temperature imbalance is occurred when the GSHP is used for a long period. Therefore, in this study, we proposed the operation method of the system that considered the recovery time of heat source temperature. The entering water temperature (EWT) and heat exchange rate (HER) were comparatively analyzed according to the continuous and intermittent operation. Furthermore, the underground thermal environment was evaluated by numerical analysis model. As the result, the intermittent operation was a maximum of 12.3% higher HER during the heating period than the continuous operation. In addition, the overall ground heat source temperature at the intermittent operation was higher than it at the continuous operation.

저심도 지중열교환기 개발을 위한 그라우트 재료에 따른 채열성능 검토 연구 (The Performance Analysis for Low-Depth Unit-type Ground Heat Exchanger According to Grouting Materials)

  • 오진환;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권2호
    • /
    • pp.7-11
    • /
    • 2015
  • Recently, as the demand for sustainable energy sources is increasing, ground-source heat pump (GSHP) systems are receiving growing attention. However, the initial cost of GSHP system is higher than it of the conventional systems, especially, in small-size buildings. Therefore, for the application to the small-size building, it is necessary to develop small-size ground heat exchanger with small-size buildings. In this study, analysis of unit-type heat exchanger due to grouting materials. As a result, 1492.14 W of heat exchange rate was acquired in the condition of cement-silica sand-graphite materials.

수평형 지열원 히트펌프 시스템에 관한 연구 (A Study on Horizontal Ground Source Heat Pump Systems)

  • 박용정;김경훈
    • 에너지공학
    • /
    • 제15권3호
    • /
    • pp.160-165
    • /
    • 2006
  • 지열원 히트펌프 시스템은 난방과 냉방부분에서 두드러진 관심을 보이고 있다. 국내에 설치된 지열원 히트펌프 시스템의 대부분은 수직형 방식으로 연구대상 또한 수직형이 주류이다. 본 연구에서는 수평형 지열원 시스템을 시설하우스에 설치하여 성능을 조사하였다. 연구결과, 히트펌프만 고려한 난방성능계수는 3.64이고 지열순환펌프를 포함한 성능계수는 3.31로 나타났다. 응축기 제거열에 대한 순환펌프의 동력은 28.0 W/kW이고, 열교환기길이는 53.3m/kW였다. 지중으로부터의 평균채열량은 14.58 W/m이고, 응축열에 대한 열교환기가 매립된 트렌치길이는 27.7m/kW였다.