• Title/Summary/Keyword: 지중공간

Search Result 188, Processing Time 0.033 seconds

A Study on Heat Transfer of an Underground Power Transmission Cable-Joint (지중송전케이블 접속부에서의 열전달에 관한 연구)

  • Park, M.H.;Kim, J.K.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.265-277
    • /
    • 1993
  • Recently, underground transmission system is growing continuously according to the electric power demand increase in the downtown area. Even if domestic cable makers are manufacturing 154kV oil filled cable and joint, the design technology of cable-joint has not been fully self-reliance. This study is aimed at the detail heat transfer analysis of 154kV cable-joint. So, that is cut into the five sections in order to analyze a conjugate natural convection in two dimensional $r-{\theta}$ coordinate. The streamline and temperature distributions are obtained for each sections. Also the changes of those are analyzed with respect to the variation of transmission currents and cable-joint surface heat transfer coefficients. The same analyses are also shown in view point of the maximum temperature of conductor and local equivalent conductivity.

  • PDF

Forced Ventilation Method for Preventing Surface Condensation of Magazine of Igloo type in Summer (강제환기를 이용한 하절기 군 저장시설의 표면결로 방지에 관한 연구)

  • Park, Sun-Hyo;Yoon, Sung-Do;Sohn, Jang-Yeul
    • KIEAE Journal
    • /
    • v.10 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • In case of earth-covered storage, the condensation occurs on surface of wall and stores in summer with high humidity because of low temperature of constructional mass. Therefore, the preventive plans should be considered to protect stores from the damage by corrosion in earth-covered storages. This study aims to suggest the methods of forced ventilation by the air, to solve the problems of construction's surface condensation at the Magazine of igloo type which is similar to earth-covered storages. A fan was installed at the air outlet for exhaust gas to conduct forced ventilation. The surface and indoor temperature were measured, and then the influence of those on condensation was analyzed. The results of this research are follows; 1) Forced ventilation by a fan affects the rise in surface temperature of walls and stores. 2) The condensation on surface of walls and stores was reduced after operating a fan.

The International Standard Trends of MV Power Cable Installation Test and its Application on Korean Standard (지중배전케이블 준공시험 관련 국제규격 동향과 국내 기준개선 방안)

  • Lee, Jae-Bong;Jung, Yeon-Ha;Song, Il-Keun;Cho, Soung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.318-319
    • /
    • 2008
  • 국내 지중배전선로에 XLPE 절연체를 사용한 전력케이블이 1980년대 중후반부터 사용되기 시작하여 20년 이상 사용경험이 축적되고 있다. 현재 국내는 전기설비기술기준에 의하여 직류내전압시험을 사용하여 준공시험을 수행하고 있다. 그러나 최근 20여년의 국제적 연구결과는 직류내전압시험이 XLPE 절연체의 결함을 발견하지 못하며 절연체 내에 장기 공간전하를 형성함으로써 케이블의 수명을 단축하는 역효과가 발생한다고 보고되고 있다. 2000년대에 XLPE 절연체를 사용한 전력케이블의 준공시험으로 초저주파(VLF) 내전압시험이 CENELEC과 IEEE 규격으로 제정되었다. 국내에도 전력케이블의 준공시험으로 초저주파 내전압시험을 도입하여 적용하는 것이 적절하며, 초저주파전압을 이용한 열화진단기술을 적용하는 것이 XLPE 절연 케이블의 고장예방에 효과적일 것으로 기대된다.

  • PDF

A Study on Applicability of Water Pipe Detecting Using GPR (상수관로 탐사에 대한 지중레이더의 적용가능성에 관한 연구)

  • Lee, Won-Jong;Lim, Sung-Min;Choi, Yun-Soo;Min, Kwan-Sik
    • Journal of Cadastre & Land InformatiX
    • /
    • v.45 no.2
    • /
    • pp.131-147
    • /
    • 2015
  • In modern society, as to the underground urban infrastructure facilities(communication electricity water and sewage gas etc.) were contained many risks because of excavating. The exact position of underground facilities and the attribute information should be built in order to prevent accidents. As the result of analyzing the public surveying results from 2004 to 2009, it shows that low detecting rate of water pipeline which is only 52.4%, because the exploration of electromagnetic induction only detect metal pipeline and positioning survey only detect new pipeline before burying. Therefore development and verification of the correct and efficient exploration techniques are needed to improve the detecting rate. In this study, determined based on the location measurement results for the non-metal pipes and metal pipes before burial. It was compared with values that obtained through the ground penetrating radar and electromagnetic induction detecting. As a result, detecting rate of the concrete section showed a 100%, unpaved section showed a 94.7%, asphalt section showed 60%. So it confirmed the applicability of the ground penetrating radar at underground facilities detecting.

An Analysis of Pore Network of Drilling Core from Pohang Basin for Geological Storage of CO2 (이산화탄소 지중저장을 위한 포항분지 시추코어의 공극구조 분석)

  • Park, Jihwan;Park, Hyeong-Dong
    • Tunnel and Underground Space
    • /
    • v.26 no.3
    • /
    • pp.181-191
    • /
    • 2016
  • In geological storage of $CO_2$, the behavior of $CO_2$ is influenced by pore network of rock. In this study, the drilling cores from Pohang Basin were analyzed quantitatively using three-dimensional images acquired by X-ray micro computed tomography. The porosities of sandstone specimens around 740 m-depth (T1), 780 m-depth (T2) and 810 m-depth (T3) which were target strata were 25.22%, 23.97%, 6.28%, respectively. Equivalent diameter, volume, area, local thickness of pores inside the sandstone specimens were analyzed. As a result, the microstructural properties of T1 and T2 specimens were more suitable for geological storage of $CO_2$ than those of T3 specimens. The result of the study can be used as input data of the site for decision of injection condition, flow simulation and so on.

A Study on the Management of the Sectional Superficies for the Realization of 3D Cadastre (입체지적 구현을 위한 구분지상권의 관리에 관한 연구)

  • Kim, HyunYoung;Lih, BongJoo
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.2
    • /
    • pp.107-123
    • /
    • 2021
  • In recent years, due to the continuous density and urbanization of space, the expansion of awareness of rights, the need for landscape conservation, and the development of construction technology, the conventional flat land use has been deviated from the conventional flat land use, and the transmission line, urban railway, parking lot, communal district, underground shopping mall, pipeline, etc. Although 3D spatial activities are carried out in the form of 3D space, there are considerable difficulties in administration to manage the 3D use of land due to the inadequacy of related regulations. In this background, for the administration that can manage Sectional Superficies, which is a representative case of 3D spatial use of parcels, which is a registered unit of land, first, the law on the establishment and management of spatial information, and cadastral re-examination from the legal and institutional aspects Standardization of 3D space registration through amendments to the Special Act, etc. and the formation of consensus among related departments. Second, in technical and administrative aspects, the registration of Sectional Superficies based on cadastral survey results, establishment of a platform for integrated management of location and attribute data, and registration method was found to be in need of improvement. As suggested in this study, by registering and managing Sectional Superficies, it is possible to manage various 3D land use of not only ground space or surface space but also underground space. It is expected to be able to register and manage lot-based 3D land use efficiently.

Numerical modelling of electromagnetic waveguide effects on crosshole radar measurements (시추공간 레이다 측정에서 전자기 도파관 효과의 수치모델링)

  • Jang, Han-Nu-Ree;Park, Mi-Kyung;Kim, Hee-Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.69-76
    • /
    • 2007
  • High-frequency electromagnetic (EM) wave propagation associated with borehole ground-penetrating radar (GPR) is a complicated phenomenon. To improve the understanding of the governing physical processes, we employ a finite-difference time-domain solution of Maxwell's equations in cylindrical coordinates. This approach allows us to model the full EM wavefield associated with crosshole GPR surveys. Furthermore, the use of cylindrical coordinates is computationally efficient, correctly emulates the three-dimensional geometrical spreading characteristics of the wavefield, and is an effective way to discretise explicitly small-diameter boreholes. Numerical experiments show that the existence of a water-filled borehole can give rise to a strong waveguide effect which affects the transmitted waveform, and that excitation of this waveguide effect depends on the diameter of the borehole and the length of the antenna.

Groundwater Management System for Prediction of Ground Subsidence (지반침하의 사전 예측을 위한 지하수 관리방안)

  • Chae, Dong Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.58-58
    • /
    • 2020
  • 최근 급속한 지하공간의 개발로 인해 도로함몰 등 지반침하가 지속적으로 발생되어 이에 대한 안전문제가 끊임없이 제기됨에 따라, 원인규명 및 대책방안을 두고 다양한 조사 및 연구가 진행되고 있다. 특히 지하개발 시 필연적으로 발생하는 유출지하수 내 지하수와 함께 토사가 유출될 경우 지반함몰이나 붕괴로 이어져 대규모 재해가 발생할 수 있기 때문에 현장에서 계측되는 데이터를 통해 사전에 지반침하를 감지할 수 있는 경보 시스템이 마련될 필요가 있으며, 이에 대한 기술개발과 관리기준의 변화가 필요하다. 본 연구에서는 현재 지하공간 개발 시 적용되는 지하수 관리 매뉴얼 중 가장 중요한 부분인 계측관리 부분에 관해 문제점을 분석하고 이를 보완하기 위한 계측 관리 및 행정 절차의 문제점을 개선하고자 한다. 지중에서 발생하는 토립자의 이동, 공동발생 및 지반함몰의 거동은 근본적으로 지하수의 이동에 의해 필연적으로 발생되며, 그 규모는 유출지하수량의 발생규모와 상관성이 높게 분석되었다. 계측 관리의 문제를 보완하기 위하여 첫 번째로 지중 굴착 시 계측되는 유출지하수와 지하수위를 연계하여 분석하여 기준을 마련하였고, 추가로 지하수 내 탁도 값을 측정하여 이를 더하여 서로간 상관성 분석을 통해 기존 지하수위 계측자료의 관리기준을 보완하였으며, 최종적으로 현장에서의 계측된 데이터를 통해 지반침하를 사전에 예측할 수 있다. 계측된 데이터의 분석결과 위험도가 감지될 경우 공동발생의 방지 및 복구에 관한 방안이 제시되며, 문제 발생 지점의 범위를 국한하여 신속하고, 경제적으로 해결해 나갈 수 있다. 이를 위해 현행 지하수법의 개선과 행정적 절차가 보완되어야 할 필요가 있다. 이러한 지하공간 개발 시 지하수 관리의 개선으로 사전에 지반침하를 예측 할 수 있고, 이를 통해 재해를 미연에 방지할 뿐만 아니라 건설산업 현장의 스마트 관리체계를 구성하여 미래 지향적인 토목현장 및 국민에 대한 신뢰도를 재고 할 수 있을 것으로 사료된다.

  • PDF

Aquifer Characterization Using Seismic Data on the Aquistore CCS Project, Canada (캐나다 아퀴스토어 탄성파자료를 통한 이산화탄소 지중저장 연구지역 대수층 특성화)

  • Cheong, Snons;Kim, Byoung-Yeop;Shinn, Young Jae;Lee, Ho-Yong;Park, Myung-Ho
    • Economic and Environmental Geology
    • /
    • v.47 no.6
    • /
    • pp.625-633
    • /
    • 2014
  • The Aquistore project is the world's first commercial capture, transportation, utilization and storage project of post-combustion $CO_2$ from a coal-fired thermo electric power plant, and the proposed storage is a saline aquifer at a depth of about 3,500 m. Deep saline aquifer, compared to hydrocarbon reservoir, provides the great volumetric potential for storage of $CO_2$ anywhere in the world, therefore the research results from the project may be exported globally to other sites. Geological $CO_2$ storage characterization for saline aquifer instead of hydrocarbon reservoir needs to estimate the geophysical properties of subsurface geology. This study calculated the geophysical property of water-saturated formation by applying amplitude variation analysis developed from oil and gas exploration. We correlated horizon tops at the well logs to seismic traveltime of 1,815 and 1,857 ms as Winnipeg and Deadwood formations. Gradient analysis from seismic traces showed correlation coefficient of 45 - 81 % on amplitude variation with respect to incident angle. Crossplot of intercept and gradient shows the inverse proportional trend which represents typical water saturated sediments. Product attribute of intercept and gradient described the base of wet sediment. Poisson's ratio change attribute increased at the top of target area satisfying with wet sediment and decreased at the top of basement in a dry rock bed.

Numerical Analysis of Load Reduction for Underground Arch Structures with Soft Zone Using Expanded PolyStyrene Geofoam (EPS Geofoam을 이용한 Soft Zone 적용방법에 따른 지중아치구조물의 하중저감에 관한 해석 연구)

  • Kim, Soo-Ha;Park, Jong-Sup;Kang, Jun-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.24-30
    • /
    • 2018
  • As the demand for underground space increases, many researchers have been studying the load reduction method using high compressible materials to solve for the stability problem of the overhead load and for the increase of the earth pressure which decreases the function of the underground structure. This paper determines the optimum soft zone and the effect of the using EPS Geofoam as a load reduction material to arch structures. A finite element analysis program, ABAQUS, is used to analyze the soil-structure interaction and the behavior of buried arch structures considering different four EPS Geofoam forms to confirm the most conservative shape. The optimum cross-sectional shape was determined by comparing the results of earth pressure reduction rate in accordance with the change of span-rise ratio and span length of the arch structure. It was confirmed that the earth pressure generated in the arch structure using the optimal soft zone selected by the numerical analysis was reduced by an average of 78%. In this study, the effect of EPS Geofoam on soil pressure reduction and its applicability to underground arch structures will provide an economical and conservative way to design underground structures and will help to increase the usability of deep underground space.