• Title/Summary/Keyword: 지점 가속도

Search Result 147, Processing Time 0.035 seconds

Maximum Power Point Tracking of Photovoltaic using Improved Particle Swarm Optimization Algorithm (개선된 입자 무리 최적화 알고리즘 이용한 태양광 패널의 최대 전력점 추적)

  • Kim, Jae-Jung;Kim, Chang-Bok
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.291-298
    • /
    • 2020
  • This study proposed a model that can track MPP faster than the existing MPPT algorithm using the particle swarm optimization algorithm (PSO). The proposed model highly sets the acceleration constants of gbest and pbest in the PSO algorithm to quickly track the MPP point and eliminates the power instability problem. In addition, this algorithm was re-executed by detecting the change in power of the solar panel according to the rapid change in solar radiation. As a result of the experiment, MPP time was 0.03 seconds and power was 131.65 for 691.5 W/m2, and MPP was tracked at higher power and speed than the existing P&O and INC algorithms. The proposed model can be applied when a change in the amount of power is detected by partial shading in a Photovoltaic power plant with Photovoltaic connected in parallel. In order to improve the MPPT algorithm, this study needs a comparative study on optimization algorithms such as moth flame optimization (MFO) and whale optimization algorithm (WOA).

Evaluation of Land Use Change Impact on Stream Drying Phenomena Using a Grid-Based Continuous Hydrologic Model (격자기반 수문 모델을 이용한 토지이용변화에 따른 하천건천화 영향 평가)

  • Jung, Chung Gil;Lee, Yong Gwan;Jang, Sun Sook;Kim, Seong Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.102-102
    • /
    • 2015
  • 최근 중소규모 하천은 하천수 및 하천변 지하수 이용의 증가와 토지이용변화 등 유역 내 수문인자의 특성 변화로 인해 하천의 건천화가 점증하고 있어 하천 환경이 악화되고 있는 실정이다. 본 연구에서는 격자기반의 분포형 장기수문 모델(PGA-CC)을 이용하여 과거 수십년동안 토지이용변화에 따른 하천 건천화 영향을 평가하였다. 실제 건천화가 진행되고 있는 삽교천 상류유역($358.8km^2$)을 선정하였고 토지이용변화분석을 위해 과거 1975년 토지이용도(Past), 현재 2008년 토지이용도(Present)를 구축하였다. 각각의 토지이용 항목 중 변화율이 가장 높은 도시비율은 과거 토지이용도에서는 2.6 %였으며 현재 토지이용도에서는 11.3 %로 8.7 %가 증가하였다. 모델 검보정은 최근 7년(2005-2011)동안 최종유역출구지점에서 유출 검보정을 실시하였다. 그 결과 NSE (Nash-Sutcliffe model efficiency)은 평균 0.71로 유출량의 모의값과 실측값이 유효한 것으로 나타났다. 건천화를 평가하기 위해 시험유역에서의 5 WPs (Watching Points)를 선정하여 과거 및 현재 토지이용조건을 모의하고 유황분석을 통한 갈수 변화량 분석을 실시하였다. 건천화 빈도분석을 위해 GEV (Generalized Extreme Value) 갈수빈도분석을 실시하여 과거 토지이용 모의결과 산정된 평균 갈수량($m^3/s$) 이하로 낮아지는 유출량 일수를 계산하였다. 최종유역출구에서 과거 및 현재 토지이용도에서 모의된 평균갈수량은 각각 $3.27m^3/s$$3.11m^3/s$로 나타났다. GEV 갈수빈도분석결과 과거 토지이용조건에서의 평균갈수량은 $3.20m^3/s$(재현기간 2.33년)으로 나타났다. 도시증가에 따른 인구증가는 지하수 사용량에 증가를 가져온다. 이는, 건천화에 영향을 미치며 본 연구에서는 지하수이용량 자료(1998-2011)를 이용하여 도시면적과 지하수이용량의 선형회귀분석을 실시하여 과거 22년 지하수 사용량을 예측하였다. 그 결과 지하수사용량 증가는 토지이용변화와 복합적으로 상류유역에 하천의 변화를 가속시키는 것으로 나타냈다.

  • PDF

An Experimental Study on Micro Shock Tube Flow (Micro Shock Tube 유동에 관한 실험적 연구)

  • Park, Jin-Ouk;Kim, Gyu-Wan;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.350-355
    • /
    • 2012
  • Past few years have seen the growing importance of micro shock tubes in various engineering applications. A pharma ballistic technique is one such application which uses micro shock tube to accelerate drug particles and penetrate into skin, thus avoiding the usual injection drug delivery system. But for the efficient design of such instruments requires the detailed knowledge of shock characteristics and flow field inside a micro shock tube. Due to many factors such as boundary layer, low Reynolds number and high Knudsen number shock propagation inside micro shock tubes will be quite different from that of the well established macro shock tubes. In the present study, experimental studies were carried out on a micro shock tube of 3 mm diameter to investigate flow characteristics and shock propagation. Pressure values were measured at different locations inside the driven section. From the experimental values other parameters like shock velocity, shock strength were found and shock wave diagram was constructed.

  • PDF

A study on the correction of rainfall-runoff model using AI models (AI 모형을 이용한 강우-유출 모형 보정에 관한 연구)

  • Haneul Lee;Seong Cheol Shin;Joonhak Lee;Hung Soo Kim;Soojun Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.96-96
    • /
    • 2023
  • 지구온난화는 집중호우 및 태풍의 빈도와 규모를 증가시키는 원인이 되었으며, 전 세계적으로 홍수로 인한 피해가 발생하고 있다. 한국에서는 2020년 홍수로 인하여 1조 이상의 피해가 발생하였으며, 2021년에는 호우로 인한 피해가 60%이상을 차지하였다. 과거에는 구조적인 대책을 수립하기 위하여 경제성 높은 치수사업을 결정하는 연구들이 수행되었다. 하지만 치수 사업은 지구온난화를 가속시키게 되며 그로 인해 집중호우의 빈도와 규모가 증가하는 악순환이 발생하게 된다. 따라서 최근에는 비구조적 대책인 홍수 예경보를 수행하여 홍수에 대응하고자 홍수 예경보 지점을 확대하고 있다. 홍수 예경보는 강우-유출 모형을 이용하여 유출량을 산정하고, 일정 수위를 초과하면 홍수 경보가 발령된다. 하지만 강우-유출 모형의 경우 많은 매개변수 값을 요구하며, 강우 사상에 따라 다른 매개변수를 산정하는데 많은 시간을 필요로 한다. 따라서 특정 강우 사상에 따라 매개변수 값을 고정하여 유출량을 산정하고 있으나, 이는 실제 유출량과 예측 유출량과의 오차가 발생할 수 있다. 따라서 본 연구에서는 강우-유출 모형의 오차를 AI로 예측하여 유출량을 보정하는 연구를 수행하고자 하였다. 강우-유출 모형에서는 유출량을 산정하고 그에 따른 오차를 생성하게 된다. 그리고 산정된 오차들을 이용하여 오차를 예측할 수 있는 AI 모형을 개발하게 된다. 최종적으로 강우-유출 모형의 유출량과 AI 모형의 오차가 결합되어 보정된 유출량을 산정하게 된다. 강우-유출 모형과 AI 모형이 결합된 Hybrid model은 기존의 단일로 사용했을 때의 발생할 수 있는 강우-유출 모형의 문제를 개선할 수 있을 것으로 판단된다.

  • PDF

Effects of Grain Size on Relationship between Microtopographic Roughness and Soil Erosion Rate (토양 입경이 미세지형의 거칠기와 토양침식률 간의 관계에 미치는 영향)

  • Soyoung Kim;Dae-Hong Kim;Tae-young Sohn
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.216-216
    • /
    • 2023
  • 가속적인 토양침식은 토지의 환경 및 생태계의 지속성에 부정적 영향을 미치므로, 그 양을 예측하여 토양침식을 방지하는 것은 중요하다. 이에 따라 식생, 지형, 토양의 입도분포 등과 같은 토양침식에 영향을 미치는 인자에 관한 연구가 꾸준히 이뤄지고 있다. 특히 자연 지형에서 보편적으로 나타나는 'cm' 규모의 미세지형이 토양침식에 미치는 영향을 분석한 기존 연구 결과를 살펴보면, 유역 출구 지점에서 관측된 총 유사유출량에만 근거하고 있을 뿐 아니라 토양침식에 미치는 미세지형의 영향에 관한 상반된 결과가 혼재하고 있다. 이는 유역의 토양침식과정에 대한 이해도와 토양침식량에 대한 예측 정확도를 저하시킬 우려가 있으므로 미세지형이 토양침식에 미치는 영향을 유역 전반에 걸쳐 살펴본 후, 명확하게 하는 것이 필요하다. 본 연구에서는 동역학파 모형에 기반한 침식 모형을 이용하여 미세지형에서의 강우-유출 및 토사 입자별 침식 및 유출 현상을 수치적으로 모의하였다. 모의 결과에 따르면, 동일한 강우-유출 조건에서도 미세지형의 거칠기에 따라 유역의 토양침식량 및 침식 특성이 달라질 수 있으며, 토양 입경이 미세지형의 거칠기에 따른 유사유출량의 증감 현상을 결정하는 데에 있어 중요한 요소로 작용함을 제시하였다. 미세지형이 거칠어짐에 따라 비교적 굵은 입자인 모래 함량이 높은 지반에서는 토양침식률이 감소하였으나 이와 대조적으로 미세토사 함량이 높은 지반에서는 토양침식률이 증가하였다. 이는 미세지형이 유역 전반에 걸쳐 입경에 따른 토사의 부상, 이류 및 퇴적 특성에 영향을 미쳐, 유역의 유사 분급 및 장갑화 현상에 깊게 관여하였기 때문이다. 본 연구를 통해 토양유실에 미치는 미세지형의 영향에 관한 상반된 연구 결과를 미세지형과 토양 입경분포의 상호작용으로 설명할 수 있다. 따라서, 본 연구는 유역 내 미세지형적 거칠기 입경분포에 대한 정확한 정보에 기반하여 토양의 유실량 및 침식량을 산정해야 함을 강조한다.

  • PDF

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Evaluation of superficial dose for Postmastectomy using several treatment techniques (유방전절제술을 시행한 환자에서 치료기법에 따른 피부선량 평가)

  • Song, Yong Min;Choi, Ji Min;Kim, Jin Man;Kwon, Dong Yeol;Kim, Jong Sik;Cho, Hyun Sang;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.225-232
    • /
    • 2014
  • Purpose : The purpose of this study was to evaluate the surface and superficial dose for patients requiring postmastectomy radiation therapy(PMRT) with different treatment techniques. Materials and Methods : Computed tomography images were acquired for the phantom(I'mRT, IBA) consisting of tissue equivalent material. Hypothetical chestwall and lung were outlined and modified. Five treatment techniques(Wedged Tangential; WT, 4-field IMRT, 7-field IMRT, TOMO DIRECT, TOMO HELICAL) were evaluated using only 6MV photon beam. GafChromic EBT3 film was used for dose measurements at the surface and superficial dose. Surface dose profiles around the phantom were obtained for each treatment technique. For superficial dose measurements, film were used inside the phantom and analyzed superficial region for depth from 1-6mm. Results : TOMO DIRECT showed the highest surface dose by 47~70% of prescribed dose, while 7-field IMRT showed the lowest by 35~46% of prescribed dose. For the WT, 4-field IMRT and 7-field IMRT, superficial dose were measured over 60%, 70%, and 80% for 1mm, 2mm, and 5mm depth, respectively. In case of TOMO DIRECT and TOMO HELICAL, over 75%, 80%, and 90% of prescribed dose was measured, respectively. Surface and superficial dose range were uniform in overall chestwall for the 7-field IMRT and TOMO HELICAL. In contrast, Because of the dose enhancement effect with oblique incidence, The dose was gradually increased toward the obliquely tangential angle for the WT and TOMO DIRECT. Conclusion : For PMRT, TOMO DIRECT and TOMO HELICAL deliver the higher surface and superficial doses than treatment techniques based linear accelerator. It showed adequate dose(over 75% of prescribed dose) at 1mm depth in skin region.

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF

지점우량 자료의 분포형 설정과 내용안전년수에 따르는 확률강우량에 관한 고찰 - 국내 3개지점 서울, 부산 및 대구를 중심으로 -

  • Lee, Won-Hwan;Lee, Gil-Chun;Jeong, Yeon-Gyu
    • Water for future
    • /
    • v.5 no.1
    • /
    • pp.27-36
    • /
    • 1972
  • This thesis is the study of the rainfall probability depth in the major areas of Korea, such as Seoul, Pusan and Taegu. The purpose of the paper is to analyze the rainfall in connection with the safe planning of the hydraulic structures and with the project life. The methodology used in this paper is the statistical treatment of the rainfall data in the above three areas. The scheme of the paper is the following. 1. The complementation of the rainfall data We tried to select the maximm values among the values gained by the three methods: Fourier Series Method, Trend Diagram Method and Mean Value Method. By the selection of the maximum values we tried to complement the rainfall data lacking in order to prevent calamities. 2. The statistical treatment of the data The data are ordered by the small numbers, transformed into log, $\sqrt{}, \sqrt[3]{}, \sqrt[4], and$\sqrt[5], and calculated their statistical values through the electronic computer. 3. The examination of the distribution types and the determination of the optimum distibution types By the $x^2-Test$ the distribution types of rainfall data are examined, and rejected some part of the data in order to seek the normal rainfall distribution types. In this way, the optimum distribution types are determined. 4. The computation of rainfall probability depth in the safety project life We tried to study the interrelation between the return period and the safety project life, and to present the rainfall probability depth of the safety project life. In conclusion we set up the optimum distribution types of the rainfall depths, formulated the optimum distributions, and presented the chart of the rainfall probability depth about the factor of safety and the project life.ct life.

  • PDF

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.