• Title/Summary/Keyword: 지열

Search Result 1,484, Processing Time 0.029 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Effect of Cooling in a Semi-closed Greenhouse at High Temperature on the Growth and Photosynthesis Characteristics in Paprika (고온기 반밀폐형온실 냉방이 파프리카 생육과 광합성 특성에 미치는 영향)

  • Kim, Eun Ji;Park, Kyoung Sub;Goo, Hei Woong;Park, Ga Eun;Myung, Dong Ju;Jeon, Yong Hwan;Na, Haeyeong
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.335-341
    • /
    • 2021
  • In this study, experiments were conducted to investigate the effects of high- temperature stress on paprika in a semi-closed greenhouse where cooling is available and a normal plastic greenhouse. Paprika grown in a semi-closed greenhouse in which geothermal cooling is provided showed a significantly higher speed of photosynthesis than paprika grown in a 3-layer plastic greenhouse in which there is no cooling system. It suggests that the photosynthesis speed of paprika in a plastic house decreases owing to high temperature stress. Plant height increased by 13cm more in the semi-closed greenhouse, and the size of leaf showed similar growth speed until the 2nd week after transplanting, however, after 3 weeks, the semi-closed greenhouse showed a big difference by 47% compared with the plastic greenhouse. In terms of the fruit count, the semi-closed greenhouse had 10.6 fruits/plant and the plastic greenhouse had 4.6 fruits/plant, indicating that the semi-closed greenhouse had a higher number of fruits by 130% than the plastic greenhouse. The fruit weight also presented a difference between the semi-closed greenhouse and the plastic greenhouse by 46%, which is 566.7g/plant and 387g/plant, respectively. According to the above mentioned results, it was validated that when paprika is cultivated in a semi-closed greenhouse where a cooling system is applied, photosynthesis and growth were better than in the normal plastic greenhouse. Thus, if the hot summer season is overcome by applying the elemental technologies for the cooling system to the normal plastic greenhouse, farm income may increase through improvement in the yield and quality.

Applied Technologies and Effects for the Carbon Zero Office Building (업무용 탄소제로건물의 적용기술 및 효과)

  • Lee, Jae-Bum;Hong, Sung-Chul;Beak, Name-Choon;Choi, Jin-Young;Hong, You-Deog;Lee, Suk-Jo;Lee, Dong-won
    • Journal of Climate Change Research
    • /
    • v.2 no.4
    • /
    • pp.283-295
    • /
    • 2011
  • Many actions against climate change have been taken to reduce greenhouse gases (GHGs) emissions at home and abroad. As of 2007, the GHGs emitted from buildings accounted for about 23 % of Korea's total GHGs emission, which is the second largest GHG reduction potential following industry. In this study, we introduced Carbon Zero Building (CZB), which was constructed by the National Institute of Environmental Research to cut down GHGs from buildings in Korea, and evaluated the main applied technologies, the amount of energy load and reduced energy, and economic values for CZB to provide data that could be a basis in the future construction of this kind of carbon-neutral buildings. A total of 66 technologies were applied for this building in order to achieve carbon zero emissions. Applied technologies include 30 energy consumption reduction technologies, 18 energy efficiency technologies, and 5 eco-friendly technologies. Out of total annual energy load ($123.8kWh/m^2$), about 40% of energy load ($49kWh/m^2$) was reduced by using passive technologies such as super insulation and use of high efficiency equipments and the other 60% ($74.8kWh/m^2$) was reduced by using active technologies such as solar voltaic, solar thermal, and geothermal energy. The construction cost of CZB was 1.4 times higher than ordinary buildings. However, if active technologies are excluded, the construction cost is similar to that of ordinary buildings. It was estimated that we could save annually about 102 million won directly from energy saving and about 2.2 million won indirectly from additional saving by the reduction in GHGs and atmospheric pollutants. In terms of carbon, we could reduce 100 ton of $CO_2$ emissions per year. In our Life Cycle Cost (LCC) analysis, the Break Even Point (BEP) for the additional construction cost was estimated to be around 20.6 years.

Clinical Significance of Reverse Redistribution on Tc-99m MIBI and T1-201 Myocardial Perfusion SPECT Images (Tc-99m MIBI와 T1-201 심근 SPECT에서 역재분포의 임상적 의의)

  • Song, Ho-Cheon;Bom, Hee-Seung;Kim, Ji-Yeul;Jeong, Myung-Ho;Gill, Kwang-Chae;Park, Joo-Hyung;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.95-103
    • /
    • 1996
  • Reverse redistribution(RRD) refers to a perfusion defect that develops or becomes more evident on rest imaging compared with the stress imaging. This phenomenon was not uncommonly noted on myocardial perfusion single photon emission computed tomography (SPECT). However, the clinical significance and pathophysiological mechanism of RRD were unclear. The aim of this study was to evaluate the incidence and clinical significance of RRD on either dipyridamole T1-201 or Tc-99m MIBI myocardial perfusion SPECT. RRD was defined as ${\geq}10%$ decrease in relative T1-201 and Tc-99m MIBI uptakes on rest images compared to the stress images or as an appearance of new perfusion defects on rest images. It was observed in both T1-201 (44/463, 9.5%) and Tc-99m MIBI (124/999, 12.4%) myocardial SPECTs similarly, with an overall incidence of 11.5%(168/1462). Many apparent)y unrelated disease groups showed the finding: post-revascularization(53.9%), coronary artery disease(24.6%), myocardial infarction(12.3%), and those with normal coro-nary arteries (9.2%). Clinical and angiographic characteristics of 65 consecutive patients who underwent coronary arteriography in 168 patients who had RRD on myocardial perfusion SPECT were reviewed. Tc-99m MIBI was used in 44 patients, and T1-201 was used in 21 patients. Of the 81 myocardial segments analyzed which showed RRD, 32 segments(39.5%) were in septum, 24(29.5%) in inferior wallL, 12(14.8%) in anterior wall, 7(8.7%) in apex and 6(7.4%) in lateral wall. There was no clear association between RRD and coronary arterial stenosis or Presence of collateral circulations. Ventriculographical wall motion was evaluated in 27 regions with RRD; it was normal in 12 regions, hypokinetic in 12 regions and dyskinetic in 3 regions. In 14 of 21 patients who showed RRD on T1-201 myocardial SPECT, T1-201 reinjection was performed immediately after the 3-4 hour redistribution studies. Ten of 14 (71.4%) showed enhanced T1-201 activity(${\geq}10%$ increased) after reinjection. We conclude that RRD is not related to mode of stress or radiopharmaceuticals. RRD might represent many inhomogeneous pathophysiological processes.

  • PDF