• 제목/요약/키워드: 지열냉난방 시스템

검색결과 119건 처리시간 0.039초

지열을 이용한 온실용 냉난방시스템 개발 (Development of a Cooling and Heating System for Greenhouse using Geothermal Energy)

  • 이용범;조성인;이재한;김태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.688-692
    • /
    • 2005
  • Importance of substitute energy has been increasing due to environmental issues and lack of fossil fuels. In addition, heating cost that occupies from 30 to $40\%$ of the total production cost in Korean protected cultivation needs to be reduced for profitability and global competition. But, studying on substitute energy to solve these problems has not been activated for Korean protected cultivation. Therefore, this study was conducted to develop a geothermal heat pump system for cool ing and heat ing of greenhouses at a lower cost than conventional hot air heater and air conditioner. Fundamental test of heat transfer characteristics in soil was conducted by computer simulation and controlled tests for its verification. Based on the results of the theoretical and empirical investigations, an optimum heat pump system was developed and the performance was evaluated for practical use in a greenhouse at the Pusan Horticultural Experiment Station. The system was compared with a conventional hot air heating system through a cucumber growing test and economic feasibility analysis. Results of the application test of the geothermal heat pump showed that with an initial setting of $15^{\circ}C$ the inside temperature of the greenhouse could be maintained between 15 and $17^{\circ}C$. Results of the cucumber growing test showed that there were no significant differences in average height, leaf length, leaf width, number of nods, leaf area, dry weight and yield between the plots wi th the geothermal heat pump system and a conventional hot air heater. Economic feasibility analysis indicated that the variable cost of the hot air heater could be saved $81.2\%$ using the geothermal heat pump system. It was concluded that the geothermal heat pump system might be a pertinent heating and cooling system for greenhouses because of the low operating cost and the use of environment-friendly geothermal energy.

  • PDF

업무용 건물의 지열 히트펌프 시스템에 대한 성능 예측 (Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building)

  • 손병후;권한솔
    • 설비공학논문집
    • /
    • 제26권9호
    • /
    • pp.409-415
    • /
    • 2014
  • Ground-source heat pump (GSHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy efficiency. These systems use the ground as a heat source and the heat sink for cooling mode operation. The purpose of this simulation study is to evaluate the performance of a hypothetical GSHP system in an office building and to assess the energy saving effect against the existing HVAC systems (boiler and turbo chiller). We collected monthly energy consumption data from an actual office building ($32,488m^2$) in Seoul, and created a model to calculate the hourly building loads with EnergyPlus. In addition, we used GLD (Ground Loop Design) V8.0, a GSHP system design and simulation software tool, to evaluate hourly and monthly performance of the GSHP system. The energy consumption for the GSHP system based on the hourly simulation results were estimated to be 582.6 MWh/year for cooling and 593.2 MWh/year for heating, while those for the existing HVAC systems were found to be 674.5 MWh/year and 2,496.4 MWh/year, respectively. The seasonal performance factor (SPF) of the GSHP system was also calculated to be in the range of 3.37~4.28.

지열을 이용한 학교시설의 냉·난방시스템 효율성분석 -에너지 소비량을 중심으로- (Efficiency Analysis of the HVAC system in the School Facilities Using the Geothermal Energy -Focused on the energy consumption-)

  • 박동순;이재림
    • 교육녹색환경연구
    • /
    • 제6권2호
    • /
    • pp.25-52
    • /
    • 2007
  • This paper is focused on the economical efficiency of the geothermal heat pump system in school. As the importance of problems of environment and energy becomes larger, the development and distribution of energy-saving technology in the whole nation has become influential. This paper is intended, targeting on school buildings scattered all over the country, to evaluate the introduction and possibility of a terrestrial heat system which is in the first stage of introduction in the country, through energy consumption and efficiency in case where a terrestrial heat system is introduced. To do that, the author performed a qualitative analysis of the heat pump system using various terrestrial heat energy and the system introduced to existing school buildings and, through the analysis, made tentative evaluation on the most environment-friendly and energy saving type system. Also, the author performed simulation analysis using a currently typical school building standard and, on the basis of this result, conducted efficiency analysis of various heat pump systems. The conclusion according to synthetical analysis & evaluation can be summarized as follows. In case a heat pump system is introduced to a school building, it was deemed the investment in the early stage would increase, but the investment could be collected within 5~6 years through reduction of large operation expenses. Also, it was analyzed in case of terrestrial heat contracted heat mode using midnight electric power among heat pump systems, not only early investment but also operation expenses could be reduced to a great extent. Accordingly in case the system using terrestrial heat energy is applied to the school buildings that are to be newly built or repaired in the future, it will provide an object-lesson to students as well as contributing to energy saving.

  • PDF

제로에너지 솔라하우스(KIER ZeSH)의 에너지 자립도 및 경제성 분석 (The Study on the Energy self-sufficiency and Economic Analysis of KIER Zero Energy Solar House)

  • 정선영;백남춘;유창균;윤응상;윤종호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.1-64.1
    • /
    • 2010
  • In this study, the energy and economic analysis of KIER Zero Energy Solar House (KIER ZeSH) was carried out. KIER ZeSH was designed and constructed in the end of 2009 for the purpose of more than 70% energy self-sufficiency in total load as well as less than 20% of additional construction cost. The several building energy conservation technologies like as super insulation, high performance window, wast heat recovery system, etc and renewable energy system. The renewable heating and cooling system is a kind of solar thermal system combined with geo-source heat pump as a back-up device. The capacity of 3.15kW solar BIPV system was also installed on the roof. The measurement by monitering system of ZeSH was conducted for one year from November 2009 to October 2010. The energy self-sufficiency and economic analysis were conducted based on the this monitering result. As a result, the energy self sufficiency is about 83% which is higher than that of the target and the payback period is 11 years.

  • PDF

OEMGD 알고리즘을 이용한 건물 냉난방용 최적 에너지 믹스 모델에 관한 연구 - 지열히트펌프와 지역냉난방 시스템을 중심으로 (A Study on the Optimal Energy Mix Model in Buildings with OEMGD Algorithm Focusing on Ground Source Heat Pump and District Heating & Cooling System)

  • 이기창;홍준희;이규건
    • 한국지역사회생활과학회지
    • /
    • 제27권2호
    • /
    • pp.281-294
    • /
    • 2016
  • This study was conducted to promote consumer interest in Geothermal Heat Pump (Ground Source Heat Pump, GSHP) and district heating and cooling (District Heating & Cooling, DHC) systems, which are competing with each other in the heating and cooling field. Considering not only the required cost data of energy itself, but also external influence factors, the optimal mix ratio of these two energy systems was studied as follows. The quantitative data of the two energy systems was entered into a database and the non-quantitative factors of external influence were applied in the form of coefficients. Considering both of these factors, the optimal mix ratio of GSHP and DHC systems and minimum Life Cycle Cost (LCC) were obtained using an algorithm model design. The Optimal Energy Mix of GSHP & DHC (OEMGD) algorithm was developed using a software program (Octave 4.0). The numerical result was able to reflect the variety of external influence factors through the OEMGD algorithm. The OEMGD model found that the DHC system is more economical than the GSHP system and was able to represent the optimal energy mix ratio and LCC of mixed energy systems according to changes in the external influences. The OEMGD algorithm could be of help to improve the consumers' experience and rationalize their energy usage.

현장타설말뚝형 에너지 파일의 시공형태별 지중 열교환량에 관한 연구 (The Effect of Construction Methods on Geothermal Exchange Rates of Cast-in-place Energy Piles)

  • 박용부;남유진;심영종;손정락
    • 토지주택연구
    • /
    • 제3권2호
    • /
    • pp.169-175
    • /
    • 2012
  • 최근, 지열 냉난방 시스템의 초기 공사비를 절감하기 위해 연구되고 있는 에너지 파일의 열교환량을 산정하기 위해 2종류(부속연결형, 슬링키형)의 현장타설말뚝형(PRD, 시공심도 4.5m, 직경 1,200mm) 에너지 파일을 시험시공하고 수치 시뮬레이션에 의해 효율을 상호 비교하였다. 상호 비교결과에 의하면 지중 교환량은 운전시작과 함께 채열에 의한 지중온도의 저하에 의해 점점 감소하였고 부속연결형의 평균 열원수의 온도차는 난방운전에서 $0.37^{\circ}C$, 냉방운전에서 $0.34^{\circ}C$로 나타났다. 또, 부속연결형의 난방운전시 열교환량 231.4W/m보다 냉방운전의 방열량은 252.2W/m로서 9% 높았고 슬링키형은 난방 기간 평균 열교환량이 168.0W/m로 부속연결형에 비해 약 27% 낮은 열교환량을 얻었다.

가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구 (An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System)

  • 공형진;강성재;윤경식;임효재
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.

열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석 (Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis)

  • 심병완;박찬희;조희남;이병대;남유진
    • 자원환경지질
    • /
    • 제49권6호
    • /
    • pp.459-467
    • /
    • 2016
  • 300 m 이상의 장심도 지중열교환기는 도심지나 넓은 부지를 확보가기 어려운 지역에 지열냉난방 시스템을 경제적으로 설치하는데 유리하다. 그러나 실제 시공에서는 여러 가지 문제들로 인하여 보편적으로 시도되지 않았고, 일반적으로 100 ~ 200m 심도로 설치되어 왔다. 본 연구에서는 일반적인 시추공 직경 150 mm에 U 파이프는 50A 규격으로 외경 50 mm의 300 m 심도로 지중열교환기를 설치하였다. 고밀도 PE관은 단위 길이당 비중이 $0.94{\sim}0.96g/cm^3$으로 지열공 내부에 채워진 지하수 영향으로 부력이 존재하여, 이를 개선하기 위해 4.6 kg 무게의 금속으로 제작된 하중밴드 10개조를 설치하여 부력의 영향을 감소시켰다. 지중열교환기의 길이 산정 및 성능평가를 위한 기초조사로서 지반조사 및 열응답실험이 실시되었다. 지반내 온도구배는 100 m 심도까지는 주변 지하수 이용에 의한 영향 등으로 $15^{\circ}C$ 정도의 분포를 보이며 그 하부는 $1.9^{\circ}C/100m$의 지온증온율을 나타내고 있다. 열응답실험은 기존에 설정된 표준 방식으로 48 시간 진행되었으며 평균 주입전력은 17.5 kW이며 평균 순환수 유량은 28.5 l/min, 그리고 평균 입출구 온도차는 $8.9^{\circ}C$로 나타났다. 측정된 지중열전도도는 3.0 W/mk이며, 공내열저항은 0.104 mk/W로 나타났다. Stepwise 평가에서 지중열전도도 변화는 초기 13시간을 제외한 이후에는 표준편차가 0.16으로 매우 안정된 값으로 수렴한 것으로 나타났다. 그리고 공내열저항의 민감도를 분석한 결과 파이프의 구경과 그라우팅 물질의 열전도도가 증가함에 따라 그 값이 미미하게 감소하는 경향을 나타내었다.

수평형 지열히트펌프 시스템의 시설원예 냉난방 실증 효과 (Heating and Cooling Effect of Portected Horticulture by Geothermal Heat Pump System with Horizontal Heat Exchanger)

  • 유영선;강연구;김영중;강금춘
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.630-633
    • /
    • 2008
  • Geothermal heat pump systems use the earth as a heat source in heating mode and a heat sink in cooling mode. These systems can be used for heating or cooling systems in farm facilities such as greenhouses for protected horticulture, cattle sheds, mushroom house and etc. A horizontal type means that a geothermal heat exchanger is laid in the trench buried in 1.2 to 1.8 m depth. Because a horizontal type has advantages of low installation, operation and maintenance costs compared to a vertical type, it is easy to be adopted to agriculture. In this study, to heat and cool farm facilities and obtain basic data for practical application of horizontal geothermal heat pump system in agriculture, a horizontal geothermal heat pump system of 10 RT was installed in greenhouse. Heating and cooling performance of this system was estimated. The horizontal geothermal heat pump used in this study had heating COP of 4.57 at soil temperature of $14^{\circ}C$ with depth of 1.75m and heating COP of 3.75 at soil temperature of $7^{\circ}C$ with the same depth. The cooling COP was 2.7 at ground temperature at 1.75m depth of $25.5^{\circ}C$ and 2.0 at the temperature of $33.5^{\circ}C$.

  • PDF

소규모 학교의 냉난방 및 신재생에너지복합시스템 적용방안에 관한 연구 (A Study on the Application Plan of Air-Conditioning and Renewable Complex Systems in the Small Schools.)

  • 김지연;박효순;홍성희;김성실;허인구;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.946-951
    • /
    • 2009
  • The research aims to study a new, optimum and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and water heating energy saving efficiencies for educational facilities. Therefore, this research carried out a study on the new/renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 174kW + solar heat collector $94\;m^2$ + highly efficient electronic cooling/heating device (EHP) 249.4kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 255.2kW + highly efficient electronic cooling/heating device (EHP) 168.2kW.

  • PDF