Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

The influence of some intrauterine growth variables on neonatal blood pressure (태아기 자궁내 성장지표와 신생아 혈압과의 관련성)

  • Min, Jungwon;Park, Eun Ae;Kong, Kyoungae;Park, Bohyun;Hong, Juhee;Kim, Young Ju;Lee, Hwayoung;Ha, EunHee;Park, Hyesook
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.966-971
    • /
    • 2006
  • Purpose : 'Programming' describes the process that stimulus at a critical period of development has lifelong effects. The fact that low birth weight links to the risk of elevated blood pressures in adult life is well known. This study aims to examine whether this link is evident in the newborn by investigating the relationship of the intrauterine growth indices and neonatal blood pressure(BP). Methods : We studied 127 neonates who were born at Ewha Womans' Hospital and their mothers enrolled our cohort study during pregnancy. Data on the mothers and details of the birth records were tracked and collected from medical charts. Neonatal BP was measured within 24 hours after birth. Results : Neonatal SBP was positively correlated to intrauterine growth indices; birth weight(BW)(r=0.4), head circumference(HC)(r=0.4), and birth height(r=0.3). However, an inverse relationship existed, between HC/BW ratio and neonatal SBP(r=-0.4). After adjusting for the baby's sex, maternal BP, and gestational age, neonatal SBP still associated with intrauterine growth indices. SBP was 7 mmHg higher in the highest BW group(${\geq}90percentiles$) compared to the lowest group(<10 percentiles). On the other hand, SBP was 17 mmHg lower in the highest HC/BW group(${\geq}90percentiles$) compared in the lowest group(<10 percentiles). Conclusion : This study could not find the evidence that intrauterine growth retardation affect on elevated neonatal BP. It suggests that the initiating events of BP programming may occur during postnatal growth period. To identify the critical starting period that intrauterine growth retardation leads to elevated BP, a study tracking BP changes from birth to childhood is required.

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.