• Title/Summary/Keyword: 지역냉방

Search Result 95, Processing Time 0.042 seconds

A study on design for free cooling system using dry cooler (드라이쿨러를 적용한 외기냉수냉방 시스템 설계에 관한 연구)

  • Yoon, Jung-In;Baek, Seung-Moon;Heo, Jeong-Ho;Kim, Young-Min;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1027-1031
    • /
    • 2014
  • Free cooling system is used to reduce energy consumption of cooling system. Free cooling system is consisted of cooling group and dry-cooler in which heat exchange of chilled water and out air is conducted. Although this system has an excellent energy saving effect in place having cooling load regularly, data or material of design for free cooling system is lacked. In this study, characteristics analysis of free cooling system is conducted through software HYSYS with changing some facts. The main result is following as : Dry-cooler capacity is influenced by out air temperature, required chilled water temperature and LMTD(Logarithmic Mean Temperature Difference) of heat exchanger. As out air temperature is more low, dry-cooler capacity become increased. in addition, as required chilled water temperature is more high and LMTD is more low, the out air temperature range is widened for using dry-cooler. If out air temperature is below $0^{\circ}C$, antifreeze need to be used because freeze and burst can be occurred. In case of South Korea, antifreeze of 34% of ethylene glycol concentration is proper. When compressor load of R22, R134a and R407C is compared, considering environmental regulation and energy consumption, R134a is best working fluid.

Analysis of Temperature Gradients in Greenhouse Equipped with Fan and Pad System by CFD Method (CFD 기법을 이용한 팬 앤 패드 냉방 온실의 온도경사 분석)

  • Nam Sang Woon;Giacomelli Gene A.;Kim Kee Sung;Sabeh Nadia
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • Evaporative cooling pad system is one of the main cooling methods in greenhouses and its efficiency is very high. However, it has some disadvantages such as greenhouse temperature distributions are not uniform and installation cost is expensive. In this study, a CFD simulation model f3r predicting the air temperature distribution in the fan and fad cooling greenhouse was developed. The model was calibrated and validated against experimental data and a good fit was obtained. The influence of different outside wind, fan and pad height, ventilation rate, shading, and greenhouse length, were then examined. In order to reduce the internal temperature gradients, it is desired that the prevail wind direction and the fan and pad heights are considered. The simulation indicates that high ventilation rates and shading contribute to reduce the temperature gradients in the fan and pad cooling greenhouse. In order to maintain the desired greenhouse temperature, the pad-to-fan distance should be restricted according to the design climate conditions, shading and ventilation rates. The developed CFD model can be a useful tool to evaluate and design the fan and pad systems in the greenhouses with various configurations.

Analysis on the Characteristics of Ventilation and Cooling for Greenhouses Constructed in Reclaimed Lands (간척지 온실의 환기 및 냉방 특성 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.181-187
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. The climatic conditions around seven major reclaimed land areas with a plan to install advanced horticultural complexes in Korea were analyzed. The characteristics of natural ventilation and temperature rise through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. Results of comparing the ventilation rate of the greenhouse according to the presence or absence of plants showed the greenhouse with plants had the lower ventilation rate, but the smaller rise of indoor temperature due to the evapotranspiration of plants. In the greenhouse with plants, the number of air changes was in the range of 0.3 to 0.9 volumes/min and the average was 0.7 volumes/min. The rise of indoor temperature relative to outdoor temperature was in the range of 1 to $5^{\circ}C$ and the average $2.5^{\circ}C$. The natural ventilation performance of the experimental greenhouse constructed in the reclaimed land almost satisfied the recommended ventilation rate in summer and the rise of indoor temperature relative to outdoor temperature did not deviate considerably from the cultivation environment of plants. Therefore, it was determined that the greenhouse cultivation in Saemangeum reclaimed land is possible with only natural ventilation systems without cooling facilities. As the reclaimed land is located in the seaside, the wind is stronger than the inland area, and the fog is frequent. This strong wind speed increases the ventilation rate of greenhouses, which is considered to be a factor for reducing the cooling load. In addition, since the fog duration is remarkably longer than that of inland area, the seasonal cooling load is expected to decrease, which is considered to be advantageous in terms of the operation cost of cooling facilities.

Energy Consumption Patterns for Various Building Types in Taejon (대전지역의 건물별 에너지 소비패턴에 대한 실태조사)

  • Kim, B.S.;Kim, Y.D.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.41-50
    • /
    • 1998
  • The purpose of this study is to analyze the energy consumption status for various building types in Taejon. 35 sample buildings were classified into 8 building types, i.e., sports center & swimming pools, hotels, telecommunication exchange service facility, hospitals, research laboratories, department stores, exhibition galleries, universities. According to analyses, energy consumption patterns varies significantly for each building type. Sports centers consumes highest rate(689 $Mcal/sqm{\cdot}yr$) and universities lowest rate(86 $Mcal/sqm{\cdot}yr$) among selected building types.

  • PDF

Load Analysis and Economical Estimation of Hot Water Driven Absorption Chiller (온수구동 흡수식 냉동기 부하분석과 경제성 평가)

  • Kim, Gi-Soo;Chung, Bong-Chul;Shin, Jeong-Kwan;Cheon, Ho-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.115-119
    • /
    • 2008
  • 지구 자원고갈과 환경오염으로 인한 에너지 절약에 대한 관심은 최근 국제유가 상승에 의해서 국가의 사활을 건 정책으로 반영되고 있다. 하루 중 부하변동이 심하지 않으면서 각실 제어가 필요하지 않은 조건을 갖춘 공간에는 지역난방공사로부터 온수를 공급받아 건물을 냉방하는 방식이 일반적으로 보급되어 있다. 최근 에너지의 유효이용 측면에서 온수 온도차를 늘려 냉방 에너지 보급용량의 확대 및 설비비용을 절감하려는 움직임이 진행되고 있다. 에너지 절약 측면에서 접근하여 볼 때 효율을 상승시키는 방법과 이용열원의 극대화가 동시에 검토되어야 하며 각각의 장점이 있는 현장에 맞추어 다양한 방식이 적용되어야 할 것이다.

  • PDF

A Study on the Cooling Load Generation for Efficient Energy Management (냉방부하 수요 창출을 통한 효율적 에너지 관리방안 연구)

  • Woo, Nam-Sub;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1007-1012
    • /
    • 2008
  • Demand for the highly efficient and high performance urban energy supply system having been continuously increased according to the rise of quality of life and continuously increased energy cost all over the world. The district heating and cooling system is very effective way for energy saving, cost reduction, and demand side management of energy. There are several district cooling supply technologies such as chilled water direct transportation, installation of absorption type chiller in the user side, and desiccant cooling. This study investigates the advantage and technical problems of each district cooling technology. Also, it is necessary political and financial support system for the extension of district cooling system.

  • PDF

Temporal and Spatial Variability of Heating and Cooling Degree-days in South Korea, 1973-2002 (한반도 난${\cdot}$냉방도일의 시공간 분포 특성 변화에 관한 연구)

  • Choi, Youn-Geun
    • Journal of the Korean Geographical Society
    • /
    • v.40 no.5 s.110
    • /
    • pp.584-593
    • /
    • 2005
  • The spatial and temporal variations of heating degree-days (HDDs) and cooling degree-days (CDDs) are closely related with the temperature field. The spatial distribution of 30-year mean HDDs shows that the higher values locates in the northern part of South Korea while the lower values locates in the southern part. The 30-year mean CDDs shows a more randomized distribution than the HDDs. The changing trends of HDDs and CDDs show a different feature: HDDs have a distinct decreasing trend while CDDs have an insignificant change. The decreasing trends of HDDs are consistent over South Korea and most of stations have experienced the statistically significant change. As significant changing areas of HDDs are much broader than those of annual mean temperature, HDDs can be more useful than annual mean temperature to detect the climate change impact on a regional level. In other words, an insignificant change on the mean temperature field can induce the significant change of thermal climatology in a region. The temporal pattern of climatic departure index (CDI) for South Korea HDDs series shows a general decreasing, but a sharp increase during recent years. The drastic decrease of HDDs induces higher CDI indicating larger variability among stations. However, the decrease of South Korea HDDs series cannot totally attribute to the global warming due to urban effects. By the early 1980s, there were no big differences of HDDs between urban and rural series, but later the differences are getting larger. This was expected to be with the intensification of urbanization in South Korea. However, still there is a decreasing trend of HDDs for rural stations.