• Title/Summary/Keyword: 지붕형 배치

Search Result 12, Processing Time 0.023 seconds

A Study on Optimizing of Roof-Top Photovoltaic Arrays Arrangement Based on Three-Dimensional Geo-Spatial Information (3차원 지형공간정보 기반 지붕형 태양광 어레이 배치 최적화 연구)

  • Kim, Se-Jong;Koo, Kyo-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.151-159
    • /
    • 2011
  • Due to the Korean government's renewable energy support policy such as the renewable energy utilization building certificate and enlarging the compulsory ratio of investment on the public building, the rooftop photovoltaic projects are expanding rapidly. It is very important for the rooftop photovoltaic projects to analyze the shading effect of the adjacent structures or own facilities. But, the photovoltaic arrangements are planned by the experience of the designers or simple graphic tools. The purpose of this study is to build the process model for optimizing of rooftop photovoltaic arrangement based on three-dimensional geo-spatial information.

Analysis of the Characteristics of Peak External Pressure Coefficient Working on Roof Surface according to the Shape and Layout of Green Houses (비닐하우스의 형태와 배치에 따른 지붕면 피크외압계수 특성분석)

  • You, Ki-Pyo;Paek, Sun-Young;Kim, Young-Moom
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.1
    • /
    • pp.59-66
    • /
    • 2010
  • Among the protected horticulture facilities in Korea, 99.2% are pipe-framed green houses and most of them are structurally vulnerable single-span type green houses. This study examined peak external pressure coefficient for the roof surface of a green house group composed of single-span and a multiple-span green houses. According to the results of the experiment, the distribution of peak external pressure coefficient was around 30% higher in the single-span greenhouse than in the multi-span ones. The external pressure coefficient for the roof surface of the vinyl house group was, in all of the three vinyl houses, was around 20%-30% higher than that for single-span greenhouses.

  • PDF

Structural Design of Domed Roof (광명 경륜 경기장 돔 구조설계)

  • Kim, Jong-Soo;Kim, Dong-Hwan;Park, Hyung-Suk;Kim, Yong-Nam;Shin, Chang-Hoon
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.255-263
    • /
    • 2004
  • 광명시 경륜 경기장은 국민 체육진흥공단에서 턴키(Turn key)공사로 발주하였고, CS구조+공간건축+대우건설, 삼성건설, 태영건설의 제출안이 당선되어 현재 시공중에 있다. 경기장의 저층부는 PC로 설계되었고, 지붕은 철골 트러스를 사용한 Dome 형상으로 이루어져 있다. 돔 지붕의 개념은 지붕에 물을 부었을 때 가장 흘러가기 쉬운 방향으로 트러스를 배치하여 유연한 힘의 흐름을 유도하는 것이다. 143.6m(폭)${\times}$183.5m(길이)${\times}$21m(높이)의 지붕엔 지붕의 개념인 Flow Truss를 물이 흐르는 방향의 방사형으로 배치하고, 내부에 압축링(Compression Ring Truss)과 외부에 인장링(Tension Ring Truss)를 설치하여 힘의 흐름을 단순화시켰고, 실내에서 보기에 플로우 트러스의 간격을 넓게 유지함으로써 개방감을 극대화시켰다. 또한 Flow Truss는 동일한 곡률과 길이로 설계하여 표준화시킴으로써 시공성과 경제성을 동시에 만족토록 하였다. 현재 저층부 시공은 거의 완료된 상황이고, 곧 지붕을 설치할 예정이다. 본 고에서는 돔 지붕의 형성 개념과 설계 과정을 살펴보고, 접합상세 등의 해결에 대해 살펴보겠다.

  • PDF

Maneuverability Analysis for Spacecraft Installed With CMGs (제어모멘트자이로를 장착한 위성의 기동성능 분석)

  • Kim, Min-young;Leeghim, Henzeh
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.4
    • /
    • pp.241-250
    • /
    • 2022
  • This paper addresses the Feasible Angular Momentum(FAM) chart that can be used as an indicator for maneuverability analysis of spacecraft installed with control moment gyros(CMGs). Recently, as the demands for high agility of spacecraft has been increasing in order to perform the space mission given to spacecraft more effectively, interest in CMGs, which is a high torque generator is increasing. However, since the CMG has a singularity problem that does not generate the control torque in the specific directions, in this paper, we consider the two pairs of parallel control moment gyros(TPCMGs) that follows the roof-type configuration. The Gimbal space was newly defined except for the space where singularity can be generated and the space where torque error is generated due to the hardware limits. The feasible angular momentum space is defined as a FAM chart, and it is very meaningful that it is possible to analyze the spacecraft's rotational maneuverability effectively by deriving the spacecraft's 3-axis parameters in the corresponding gimbal space mathematically.

Analysis on Heat Loss of Single-span Greenhouse Using Small-scaled Wind Tunnel (소형풍동을 이용한 단동 비닐온실의 열손실 분석)

  • Kim, Young Hwa;Kim, Hyung kow;Lee, Tae suk;Oh, Sung sik;Ryou, Young sun
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2020
  • The objective of this study is to analyze the heat transfer loss of covering materials in a single-span plastic greenhouse under the steady-state wind environment. To achieve this objective, the following were conducted: (1) design of a small-scaled wind tunnel (SCWT) to analyze heat losses of the greenhouse and its performance; (2) determination of the overall heat transfer coefficient (OHTC) for the covering materials using a small-scaled greenhouse model. The SCWT consists of the blowing, dispersion, steady flow, reduction and testing areas. Each part of the SCWT was customized and designed to maintain air flow at steady state and to minimize the variances in the SCWT test. In this study, the OHTCs of the covering materials were calculated by separating each with the roof, side wall, front and back of the small-scaled greenhouse model. The results of this study show that the OHTC of the roof increases as wind speed increases but the zones in which the increase rate of the OHTC decreased, were distinguished by wind tunnel wing speed of 2 ms-1. For the side wall, the increase rate of the OHTC was particularly higher in the 0-1 ms-1 zone.

A Study on the Interior Style of American Colonial Housing (미국 콜로니알 주택과 실내 양식에 관한 연구)

  • 김정근
    • Archives of design research
    • /
    • v.17 no.2
    • /
    • pp.261-268
    • /
    • 2004
  • The Colonial House is one of the most popular styles in America. The purpose of this study is to closely examine this style based on interior features classified by patterns and elements during America's colonial period. Results of this study show that the interior style of the Colonial House was, at first, similar to Europe style. It was then integrated into the Georgian style of England and affected by Palladio as time passed. The interior style of the American Colonial House was based on rationality and practicality in concern with American weather and regions rather than imitation. The side of the roof was clapboard and the windows arranged with symmetry and rules around the entrance hall. It was generally Palladian style and was decorated with classical details. Timber frame of the interior was based on log cabins that appeared early in the American immigration. Furniture styles such as Jacobian, Queen Ann and Chippendale were matched with unique wood-oriented details and folkways like Chest, Rush Chair and Windsor Chair The house was also decorated with pictures, mirrors and ornaments, etc.

  • PDF

THE FORMAL ANALYSIS OF PANTHEON IN ROME IN RELATION TO THE SOLAR ANGLES (로마 판테온의 일조특성 연구)

  • Lim, Choong-Shin
    • Journal of architectural history
    • /
    • v.7 no.4 s.17
    • /
    • pp.191-198
    • /
    • 1998
  • The form of Pantheon in Rome is graphically analyzed in relation to the angle of the Sun that varies through four seasons of the year. These are worked out in the Autocad drawing files for exactitude and efficiency. Some of the results suggest that the Pantheon is carefully designed to predict the equinoxes and the solstices.

  • PDF

A Study on the Design Concept & Construction Method of Office Building with Stacks at Thermal Power Plant (화력발전소 연돌통합형 종합사무동의 설계개념과 시공공법 연구)

  • Kim, Si-Hyun;Choi, Jang-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.677-686
    • /
    • 2016
  • A thermal power plant is the first CFBC (Circulating Fluidized Bed Combustion) power plant consisting of 2 boilers-1 turbine. The optimal height of a stack needs to be approximately 156 meters in the case of this thermal power plant; however, the thermal power plant sites satisfy a function and reduce the construction cost by using mountains in the sites after cutting the ground and locating an integrated office and chimney at an altitude of 70 meters thereby lowering the height of the stack to 86 meters. In addition, the integrated office, which has a combined stack style with a unique design, is constructed by connecting with 2 stacks and disposing the office and an observatory in the space between them. Therefore, this study examined the design concept that fulfils the structural, functional, and aesthetic factors, harmoniously by joining the integrated office and the stack, which are disparate, and investigated special construction methods (Slip Form, Steel Inner Flue & Lift-up) through which heterogeneous architectures are structurally, functionally, and aesthetically constructed.

Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses (토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.215-224
    • /
    • 2009
  • A survey on the actual state of heating, cooling, ventilation, and air-flow and experimental measurement of temperature and humidity distribution in tomato greenhouse were performed to provide fundamental data required in the development of air-flow control technology. In single-span plastic houses, which account for most of 136 tomato greenhouses surveyed, roof windows, ventilation and air-flow fans were installed in a low rate, and installation specs of those facilities showed a very large deviation. There were no farms installed greenhouse cooling facilities. In the hot air heating system, which account for most of heating type, installation specs of hot air duct showed also a large deviation. The exhaust air temperature and wind speed in hot air duct also were measured to have a big difference depending on the distance from the heater. We are using the maximum difference as indicator to determine whether temperature distribution is uniform. However if the temperature slope is not identical in greenhouse, it can't represent the uniformity. We analyzed relation between the maximum difference and the uniformity of temperature and humidity distribution. The uniformity was calculated using the mean and standard deviation of data from 12 measuring points. They showed high correlation but were represented differently by linear in the daytime and quadratic in the nighttime. It could see that the uniformity of temperature and humidity distribution was much different according to greenhouse type and heating method. The installation guidelines for ventilation and air-flow fan, the spread of greenhouse cooling technology for year-round stable production, and improvement of air duct and heating system, etc. are needed.