• Title/Summary/Keyword: 지반 강성

Search Result 709, Processing Time 0.021 seconds

Estimation of Nonlinearly Distributed Active Earth Pressure on Rigid Retaining Wall (강성옹벽에 작용하는 비선형 주동토압의 산정)

  • 백규호
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.443-450
    • /
    • 2002
  • It is known that the distribution of the active earth pressure against a translating rigid wall is not triangular, but nonlinear, due to arching effects in the backfill. In the present paper, a new formulation for calculating the active earth pressure on a rigid retaining wall undergoing horizontal translation is proposed. It takes into account the arching effects that occur in the backfill. In order to check the accuracy of the proposed formulation, the predictions from the equation are compared with both existing full-scale test results and values from existing equations. The comparisons between calculated and measured values show that the proposed equations satisfactorily predict both the earth pressure distribution and the total active earth force on the translating wall.

  • PDF

Seismic Response of Soil-Reinforced Segmental Retaining Walls by Finite Element Analysis (유한요소해석에 의한 블록식 보강토 옹벽의 지진시 응답특성)

  • 유충식
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.15-25
    • /
    • 2001
  • 본 고에서는 블록식 보강토 옹벽의 지진시 거동에 관한 유한요소해석 결과를 다루었다. 보강토 옹벽의 지진시 변위거동을 검토한 결과 벽체저부를 지점으로 하는 캔틸레버형태의 변위 거동을 보였으며 따라서 옹벽 상단부에서의 보강재 인장력 증가가 현저하게 나타나 벽체전반에 걸친 분포양상은 균등한 경향을 보였다. 한편, 지진하중으로 인한 증분유발인장력에 관하여 검토한 결과 기존의 보강토 옹벽 내진설계기준과 비교하여 정성.정량적인 측면에서 상당한 차이를 보였으며 내진설계기준이 전반적으로 과소평가 하는 것으로 나타났다. 아울러서, 내진설계측면에서 변위억제 방안에 관한 매개변수 연구결과 임의 조건에 있어서 최대의 보강효과를 나타내는 보강재 임계 강성과 포설길이가 존재하며 최적의 보강효과를 얻기 위해서는 이에 대한 종합적인 검토가 요구되는 것으로 나타났다. 본 고에서는 연구결과를 종합적으로 고찰하여 실무 적용관점에서의 주안점을 언급하였다.

  • PDF

The Engineering Properties of Shear Strength of Rock Joints in Korea (국내에 분포하는 주요 암석의 절리면 전단강도에 대한 공학적 성질)

  • 김대복;이상근;이정인
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.301-315
    • /
    • 2001
  • 본 연구에서는 최근 5년간 국내 각 지역에서 채취한 802개의 절리면 시료에 대하여 전단시험을 실시하여 얻은 결과를 이용하여, 절리면의 여러 공학적 성질들을 조사, 연구하였다. 절리면 전단시험에서 얻어진 최대마찰각 및 잔류마찰각을 지체구조별, 암종별로 분류하고 통계적으로 구하였으며, Barton의 전단강도식의 입력변수인 JRC, JCS를 측정하고 Barton식의 적용성에 대해서도 검토하였다. 그 결과 설계의 기초자료로 활용할 수 있는 지역별, 주요 암종별 최대마찰각, 잔류마찰각을 제시하였다. 또한, JRC, JCS, 수직응력에 따른 마찰각과 전단강성 및 팽창각의 변화를 분석하였다. 마지막으로, Barton의 식에서 구한 이론적 전단강도와 이 실험에서 얻어진 전단강도를 비교한 결과, Barton의 경험식은 높은 상관도로 암석 절리면 전단강도를 예측할 수 있음을 확인하였다.

  • PDF

Research on the railroad reinforcement subgrade with short reinforcement and rigid facing (강성벽체와 단보강재를 갖는 철도보강노반에 대한 연구)

  • Kim, Dang-Sang;Kim, Ki-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.350-358
    • /
    • 2009
  • To enhance the application of the reinforced retaining walls in the railway industry, this paper suggested a type of reinforcement subgrade with short reinforcement and rigid facing. To become popular the reinforced retaining walls in the industry, the deformation of retaining walls should be controlled below some limited level. In this paper, small scale and full scale tests of the proposed retaining walls were performed and their deformation characteristics were evaluated. Even though it has short reinforcement, the rigid type retaining wall had small deformation to the external train loading than the segmental type retaining wall had.

  • PDF

A Study on the Improvement of Vibration Environment by Wave Barrier (방진벽에 의한 진동 환경 개선 연구)

  • Huh, Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.63-71
    • /
    • 2000
  • 대부분의 경우 지반을 통해 전달되는 진동을 줄이기 위해 사용되는 방진벽의 차진효율은 지반 위 한 점에서의 진폭저감계수로 표현되고 있다. 그러나 한 점에서의 진동차단 효율은 일정 지역의 평균값과 많은 차이를 보이고 있어, 일정 단지의 진동환경 개선에 요구되는 경우, 한 점에서의 값만으로 차진효율을 표현하는 것은 적합하지 않다. 이를 위해 본 논문에서는 단지 내 진동환경 개선의 판단방법을 제시하고, 방진벽의 기하학적 규모가 방진벽의 진동차단 효율에 미치는 영향을 경계요소법을 이용하여 구하였다. 해석결과에 의하면 강성 방진벽의 경우, 단면적인 방진벽의 차진성능에 큰 영향을 미치는 것으로 나타났다.

  • PDF

Identification of ambient pore pressure and rigidity index from piezocone dissipation test (피에조콘 소산시험을 이용한 평형간극수압과 강성지수의 역해석)

  • 김영상
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.49-54
    • /
    • 2002
  • This paper describes a systematic way of simultaneously identifying the ambient pore pressure and the rigidity index (=G/s$\_$u/) of soil by applying an optimization technique to the piezocone dissipation test result. An ambient pore pressure and optimal rigidity index were determined by minimizing the differences between theoretical excess pore pressures developed by Randolph & Wroth(1979) and measured excess pore pressures from piezocone using optimization technique. The effectiveness of the proposed back-analysis method was examined against the well-documented performance of piezocone dissipation tests (Tanaka & Sakagami, 1989), from the viewpoints of proper determination of selected target parameters and saving of test duration. It is shown that the proposed back-analysis method can evaluate properly the ambient pore pressure and the rigidity index by using only the early phase of the dissipation test data. Also, it is shown that with the optimized rigidity index and ambient pore pressure the proposed back-analysis method permits the horizontal coefficient of consolidation to be identified rationally.

  • PDF

An Experimental Study on Behavior Characteristic of the Soil Nailed Wall with Facing Stillness (전면벽체 강성에 따른 쏘일네일링 벽체의 거동특성에 관한 실험적 고찰)

  • 김홍택;강인규;권영호;조용훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.279-286
    • /
    • 2002
  • Recently, there are many attempts to expand a temporary soil nailing system into a permanent wall due to the advantage of soil nailing system, that is efficient and economic use of underground space and decreasing the total construction cost. However, the proper design approach of a permanent soil nailing system has not been proposed by now in Korea. Permanent soil nailing system which utilizes precast concrete walls for the facing of soil nailing system Is already used in many countries. In general, the cast-in-place concrete facings or rigid walls were constructed in bottom-up way after construction of soil nailing walls finished preliminarily In this paper, various laboratory model tests have been carried out to investigate the failure mode, behavior characteristics, and tensile force at nail head in each load level in respects of the variation of stiffness of the facing.

  • PDF

Measurement of Soft Ground Foundation and Rock Slope Behavior Using Spiral Bolt Strain Gauge (스파이럴 볼트 변형률계를 이용한 연약지반기초 및 암반사면 거동 계측)

  • Kang, Seong-Seung;Hirata, Atsuo;Jeong, Seong-Hoi;Lee, Woo-Ram;Je, Dong-Kwang;Kim, Dae-Hyeon
    • Tunnel and Underground Space
    • /
    • v.20 no.2
    • /
    • pp.105-111
    • /
    • 2010
  • This study is to consider applicability of spiral bolt strain gauge as an instrument measuring behavior of soft ground foundation and rock slope. When the instrument was installed on the ground, it can be useful to identify the state of ground behavior because it has the characteristics of flexibility, as well as to apply the ground reinforcement because it has higher pull-out resistance to the ground. From the measurement of behavior to soft ground foundation, the strain shows a stable state in the beginning, then was observed significant change in the upper and the middle of spiral bolt strain gauge after 400 days. This is analyzed that ground loosening, which is due to occurred frequent earthquake of magnitude 1~2 with increased rainfall, lead to the instability of the ground. From the measurement of behavior to rock slope, the strain shows a stable state with very little change in a period of 0~50 days and the biggest strain at 4.2 m (P6) in a period of 50~100 days, then other places except P6 was maintained at a stable state in a period of 100~160 days. The reason is analyzed because that blasting for excavated limestone surrounding was affected to the largest at P6. However, based on the size of strain change by behavior of the soft ground foundation and rock slope, it is considered that the present condition are not effected on stability of retaining structure and rock slope. In conclusion, the proposed spiral bolt strain gauge can be useful to measure behavior of soft ground foundation and rock slope, and also to be measured behavior as well as reinforcement of the target ground.

Experimental Study on the Ground Behavior around a Tunnel due to the Sidewall Deformation of Shallow Tunnel in Longitudinal Direction Excavated under the Slope (사면 하부지반에 종단 방향으로 굴착한 얕은 터널에서 측벽변형에 따른 터널 주변지반의 거동에 대한 실험적 연구)

  • Na, Yong Soo;Lee, Sang Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.5
    • /
    • pp.21-30
    • /
    • 2019
  • While the study of the shallow tunnel has been mainly on the longitudinal load transfer and horizontal surface conditions, the study of the ground behavior of shallow tunnel under the slope is not sufficient. Therefore, in this study on the ground behavior around a tunnel due to the sidewall deformation of shallow tunnel under the slope that is excavated in longitudinal direction, a scale-down model test has been performed. The model tunnel has the dimension of 320 mm wide, 210 mm high and 55 mm long with enough material strength in aluminum and the model ground has the uniform ground conditions by 3 types of carbon rods. The model test has been performed with the variables of slopes and the cover depths by controlling the tunnel sidewall deformation, and the change of sidewall-load, load transfer, ground subsidence was monitored and analyzed. According to the increase of the slope, the maximum ground subsidence increased by 20~39% compared to the horizontal surface. The load ratio increased by maximum 20% in the tunnel crown and decreased in sidewall according to the surface slope. The load transfer shows maximum 128% of increase at the cover depth of 1.0D, while at the 1.5D cover depth it shows non-critical difference from horizontal surface. The slope has major effects on load transfer at the cover depth of 1.0D.

A Behaviour Analysis on Clayey Ground and Steel Sheet Piles Subjected to Unsymmetrical Surcharges (편재하중을 받는 점토지반과 강널말뚝의 거동해석)

  • Lee, Moon Soo;Lee, Byoung Koo;Jeong, Jin Seob;Kim, Chan Kee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.977-988
    • /
    • 1994
  • In this paper, the comparisons between field measurments and numerical results ware performed for the settlements, lateral displacement in Jinwol interchange works on the Honam express way whose site was improved by sand drain for the constructions of over bridges, piers and abutments. The computer program was developed by coupling Biot's equation with Sekiguchi's elasto-viscoplastic model under plane strain conditions. Steel pipe piles for piers were replaced into the equivalent steel sheet pile wall. The characteristics of behavior for both the soil foundations and the sheet piles wall were investigated with the variation of axial force on the wall, rigidity of the wall, supported condition of sheet pile into hard strata and the location of anchored point.

  • PDF