• 제목/요약/키워드: 지락과전류

검색결과 11건 처리시간 0.026초

소형 열병합 발전소의 계통연계시 방향성 과전류 및 지락과전류 계전기의 적용 검증 연구 (A Study of Verification on Application of Directional OCR and OCGR for Power System with Small Scale Cogeneration)

  • 이희태;조만영;김재철
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.944-950
    • /
    • 2008
  • When small cogenerators are operated in connected with power system, there are many positive aspects such as the reduction of power plant construction, making a improvement of power security etc. At the same time, there are some negative effects or difficulties such as we should make sure of protective coordination, especially, Actually these are not fault, but it is likely to consider the current as the fault. This is one of major causes of malfunctions for protective relays in power distribution system which is including interconnection point. Thus, in this paper, We showed that the directional protection is necessary to the dispersed generation system which is including connection point. We also executed contingency analysis to find out the magnitude of fault current and direction which are classified by fault points, length of line and kinds of faults using ETAP power system analysis program.

발전기 고장보호를 위한 디지털 계전기에 관한 연구 (A Study on the Digital Protective Relay for Generator Fault Protection)

  • 장낙원;박정도;이성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권8호
    • /
    • pp.1232-1238
    • /
    • 2009
  • 전력설비의 대용량, 고전압화 됨에 따라 발전기 고장 예방을 위한 고장보호시스템의 필요성이 점차 증대되고 있다. 신속하고 신뢰성 있게 운전하며 보호하는 발전기 보호제어 시스템의 개발이 시급히 요구된다. 본 논문에서는 전력 공급의 안정을 도모하고 대용량, 고전압화 되는 발전기의 고장 예방을 위한 발전기 보호기능을 갖춘 디지털 보호계전기 설계에 관한 연구를 수행하였다. 디지털 계전기의 발전기 고장보호에 사용되는 고장보호 알고리즘을 개발하였고 디지털보호계전기 H/W를 설계 제작하였다.

소수력발전기의 자동전압조정기 Fault에 의한 정지원인 분석 (Analysis of trip by AVR in small hydraulic power generator)

  • 박두용;임익헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.518-519
    • /
    • 2008
  • 소수력 발전설비(1000kw 3대)가 연결되어 있는 22.9kV 선로상에서 순간적인 지락사고가 발생한 경우에 계통 보호계전기는 설비보호차원에서 지락과전류 보호요소에 대해 재폐로시간을 고려하지 않고 0.5초이내에 트림이 되도록 설정되어 있어 대부분의 선로고장에 대해서 민감하게 동작하고 있다. 2차례의 트립원인을 분석한 결과 순간적인 계통전압의 상승이 관찰되어 재기동하여 병입한 후 동일상황이 발생하는 강매에서 역률설정치를 낮추어 계통전압과 평형을 맞춤으로 해서 트립을 방지할 수 있었으며, 소수력의 자동전압조정기 Fault에 의한 정지원인 분석한 결과이다.

  • PDF

저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구 (A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank)

  • 손석금
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.562-567
    • /
    • 2020
  • 본 논문은 저장 탱크용 임시전력설비를 보호하기 위한 목적으로 특히 변압기를 감시하고 절연파괴 등과 같은 고장을 차단하고 보호하기 위한 보호계전기 정정에 관한 연구이다. 전력계통에 단락 또는 지락고장 등과 같은 이상이 발생하였을 때 이를 검출하여 고장이 발생한 기기 및 설비를 신속하게 차단하고 전력계통으로부터 분리하여 전력공급에 지장이 없도록 하여야 한다. 전력계통의 이상 상태를 빠르고 정확하게 감지할 수 있는 보호계전기의 정정이 중요하다. 또한 보호협조를 위해 고장종류와 고장의 원인을 정확히 적용한 고장전류 계산이 보호계전기 정정에 가장 중요한 요소이다. 저장 탱크용 임시전력설비 보호를 위해 적용하는 과전류계전기, 지락과전류계전기, 부족전압계전기, 지락과전압계전기 등이 보호협조가 가능하도록 보호계전기 정정 방법에 대해 연구하였다.

방향지락과전류계전기를 이용한 고저항지락사고 검출능력의 향상방안 (A New Scheme to Improve High Impedance Fault Detection Capability Using Directional Over-Current Ground Relay)

  • 이승재;임종윤;김일동;한경남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1000-1002
    • /
    • 1997
  • In this paper we proposes a scheme which can improve the detecting capability of the high impedance fault of the conventional distance relaying. It utilizes the directional ground overcurrent relay called HIFR together with the distance relay in order to secure the security and selectivity.

  • PDF

송전계통 고저항지락사고 보호를 위한 지락과전류계전기 적용방안 (The application of Overcurrent Ground Relay(OCGR) for High Impedance Fault Protection in Transmission Systems)

  • 이승재;임종윤;이종범;김철환;김영한;김일동;한경남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.127-129
    • /
    • 1996
  • 고저항지락사고시 선로의 지락후비보효용인 지락거리계전기 및 변압기 후비보호용 방향지락과 전류계전기의 비협조 문제로 인하여 광범위한 정전이 유발될수 있다. 본 논문에서는 이에 대한 대책으로 고저항지락보호용 과전류계전기의 도입과 적용방안에 대하여 제안한다.

  • PDF

MTR 중성점 접지에 초전도 전류제한기 적용시 지락과전류계전기 동작 분석 (Analysis on the Protective Coordination on Neutral Line of Main Transformer in Power Distribution Substation with Superconducting Fault Current Limiter)

  • 김진석;임성훈;문종필;김재철;현옥배
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2089-2094
    • /
    • 2009
  • The fault current has increased due to growth of distributed generations for the large power demand in power distribution system. To solve some problem such as excess of the circuit breaker's cut-off ratings, the superconducting fault current limiter(SFCL) has been progressed. However, the operational characteristics of the relay is changed by SFCL. Therefore, the proper impedance for the SFCL should be selected to keep protective coordination with the SFCL when SFCL is introduced on the neutral line of main transformer in distribution system. In this paper, the proper normal conducting resistance was suggested to solve the problem in case of the protection coordination with SFCL.

비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구 (A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection)

  • 김경철;고훈
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.

EMTP를 위한 Scott변압기 모델링 (Scott Transformer Modeling for EMTP)

  • 조성돈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.387-389
    • /
    • 2005
  • Scott 결선 변압기는 3상전원에서 단상부하를 공급해야하는 계통에서 많이 사용되고 있다. 특히 전기철도가 이에 해당되며 국내에서는 전기철도의 화장으로 Scott변압기가 154kV급의 송전계통에 연계되어 설치 운전되고 있다. Scott변압기의 특성상 단상인 부하측 또는 3상인 전원측에서 사고 발생시 각상에 흐르는 불평형 사고전류의 예측이 어려워 관련기기의 선정과 각종 보호계전기의 정정이 쉽지 않았으며 과도현상 해석도 쉽지않았다. ATP(Alternative Transient Program)는 전력계통의 과도현상뿐만 아니라 단락 및 지락과 같은 정상상태 해석 및 고조파 분석도 가능하며 그래픽 유저 인터페이스를 위한 ATPDraw도 개발되어 데이터 입력과 사용법이 보다 간편하게 되었으며, 출력파형을 위한 PlotXY도 개발되어 계산결과를 다양한 형태의 그래프로 출력할 수 있게 되었다. 무엇보다도 User Group에 가입하면 무료로 모든 프로그램을 사용할수 있는 장점도 있다. 본고에서는 ATP를 사용하여 Scott변압기의 모델링과 이를 통한 단락 및 지락 사고 둥의 해석 사례를 소개하였다.

  • PDF

배전선의 고장해석을 위한 지락 및 단락 시험장치 개발 (Development of Ground and Short Test Equipment for Fault Analysis of Distribution Line)

  • 김응상;이재복
    • 에너지공학
    • /
    • 제9권3호
    • /
    • pp.243-249
    • /
    • 2000
  • 대체에너지에 대한 연구가 활발히 진행됨에 따라 향후 배전계통은 신 에너지 전원 등과 같은 분산형 전원과 연계되어 네트워크 형식으로 구성될 것으로 예상된다. 이러한 배전계통의 변화는 지락 및 단락 사고 시 기존의 보호협조에 있어서 많은 문제점을 발생시킬 것이며, 이러한 배전계통의 변화와 전력 고품질 요구에 대응하기 위해서는 새로운 보호협조 체계가 필요하다. 새로운 보호협조 방식의 개발을 위해 필수적인 지락과 단락사고 시 배전계통의 사고 데이터는 실제 운영 도중에 얻기 어렵다. 본 논문에서는 기존 전원시스템 및 신 에너지 전원을 포함한 새로운 배전계통의 운용시 발생할 수 있는 사고 상황을 예측하고 고장 데이터를 수집하기 위해 저압 배전선로에 인위적으로 지락 및 단락을 발생시킬 수 있는 장치의 개발에 대해 서술한다. 개발한 시험장치의 기능을 확인하기 위하여 실제 배전계통에 적용하여 지락 및 단락 시험을 수행하여 전압 및 전류 파형을 측정·분석하여 시험장치의 신뢰성과, 효용성을 검증하였다.

  • PDF