• Title/Summary/Keyword: 지대치 재료

Search Result 61, Processing Time 0.023 seconds

The Clinical Application of an All Ceramic Bridge -A Copy Milling(Celay) Technique (Copy Milling(Celay) System을 이용한 All Ceramic Bridge 임상 증례)

  • Kim, Dae-Hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.9 no.1
    • /
    • pp.82-90
    • /
    • 2000
  • In esthetic dentistry, color and strength are basic requirements for the long-term success of the restorative materials. Several all ceramic systems have been introduced to esthetic dentistry recently. However, the inherent natures of ceramic material, the application of all ceramic system is mainly limited to single tooth restorations. With the improvement of material science, the alumina and zirconia/alumina composite power and block can be applied to fabrication of all ceramic bridges. The conventional inceram core fabrication takes time for sintering however, the shaping of block with a copy milling machine can reduce great amount of time. The block is easy to manipulate and prepare in any shape accurately. This clinical report demonstrates the application of all ceramic ante rior 3 unit bridge with a alumina block in CELAY system.

  • PDF

Soft tissue responses to differential shapes of the implant abutment (임플란트 지대주 모양에 따른 주위 연조직 반응에 관한 연구)

  • Ahn, Soo-Yong;Han, Chong-Hyun;Heo, Seong-Joo;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Lee, Hae-Jun;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.167-177
    • /
    • 2006
  • 연구배경 임플란트에 관한 전통적인 연구들은 주로 임플란트 매식체와 골조직간의 결합에 중점을 두어왔다. 최근 임플란트의 심미적 관점에 대한 관심이 높아지면서 임플란트 주위 연조직의 재건 및 유지에 대한 연구들이 많이 이루어지고 있다. 이번 연구는 임플란트 주위 연조직이 임플란트 지대주의 모양에 따라 어떻게 반응하는지 알아보고자 한다. 연구방법 및 재료 2 마리의 성견을 대상으로, 먼저 하악의 모든 소구치를 발치하고, 3개월의 치유 기간 후에 각 4분악에 실험에 사용된 3개의 다른 모양의 지대주를 가진 임플란트를 식립하였다: (1) 위로 벌어진 모양의 지대주 (2) 안쪽으로 오목하게 좁아진 지대주 (3) 평행한 모양의 지대주. 식립 순서는 무작위로 하였으며, 3개월 후 실험동물을 희생하고 조직 표본을 얻었다. 조직 표본은 광학 현미경을 통해 관찰하고, 상피, 결합조직, 전체 연조직의 수직적 거리를 측정하여 비교하였다. 연구 결과 이번 연구에서 임플란트 주위의 연조직을 측정한 결과, 접합 상피는 1.21 ${\pm}$ 0.47 mm, 결합조직은 1.16 ${\pm}$ 0.39 mm, 전체 연조직 두께는 2.37 ${\pm}$ 0.47 mm로 이전의 연구들과 비슷한 결과를 보였다. 지대주 주위의 연조직 중 결합조직이 많은 부위에서는 여러 주행 방향의 교원 섬유들이 관찰되었다. 그 중에서 결합조직이 차단막으로써의 역할을 할 수 있도록 하는 원형으로 주행하는 교원 섬유들이 모든 지대주 모양에서 관찰되었다. 특히 오목하게 좁아진 모양을 가진 지대주에서는 오목하게 파인 부분으로 많은 원형으로 주행하는 교원 섬유들이 관찰되었다. 오목한 모양의 지대주는 다른 모양의 지대주에 비해서 측면 방향의 연조직 두께가 두꺼웠다. 특히 위로 벌어진 모양의 지대주에 비해서 두꺼운 연조직을 확보할 수 있었으며, 내부에 많은 결합조직 교원 섬유들을 관찰할 수 있었다. 결론 이번 연구에서 오목한 모양의 지대주가 연조직을 두껍게 유지하고, 많은 원형으로 주행하는 교원 섬유들을 확보할 수 있었다. 이를 통해 오목한 여태의 지대주가 연조직 유지에 더 유리하고, 따라서 심미적인 부위에서 연조직의 퇴축을 예방하는데 더 유리하다고 할 수 있다.

전치부 고정성 보철치료를 위한 인상채득시 주의사항

  • Baek, Seung-Jin
    • The Journal of the Korean dental association
    • /
    • v.39 no.11 s.390
    • /
    • pp.892-897
    • /
    • 2001
  • 인상(impression)은 치과임상에서 매일같이 반복되는 과정이다. 본문에서는 주로 전치부심미보철을 위한 인상채득 방법에 대해서 알아보고자 한다. 모든 종류의 보철물에서 인상 채득은 필수적이르므로 인상 재료의 여러가지 성질과 그 특성에 대해서 잘 알아야 할 필요가 있다. 치은연하 변연의 경우에 정확한 인상 채득을 위해서는 치은압배가 필요한데, 여기에서는 지대치삭제 요령, 치은압배술 및 인상채득시 주의사항에 대해 살펴보기로 한다.

  • PDF

Implant-supported fixed prostheses with high-performance polymer (PEKK) abutments in partial edentulous patients: A case report (부분 무치악 환자에서 고기능성 폴리머(PEKK) 지대주를 이용한 임플란트 고정성 보철물 수복 증례)

  • Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • Implant treatment, which was first attempted in fully edentulous patients, is now widely used in partially edentulous, and a single tooth missing patients. Moreover, implant treatment has become an essential treatment modality in modern dentistry. The material of fabricating implant prostheses has also become more diverse than before, one of which is the use of high-performance polymers. The frequency of using high-performance polymers, which have been used in the medical field, is also increased in the dental field compared to the past. In the first case, a PEKK abutment and a PFG crown (cement-screw-retaining type) were fabricated in the lower left second premolar, and in the second case, a PEKK abutment and a monolithic zirconia crown (cement-screw-retaining type) were fabricated in the missing upper left first molar, and in the third case two PEKK abutments and a splinted PFM crowns (cement-screw-retaining type) were fabricated and connected to the upper right first and second molar implants. Through these procedures the patients obtained esthetically and functionally satisfactory results after 4 years of follow-up.

Fiction Coefficient between Abutment Materials and Clasp Materials and Estimation of Retention Force of Circumferential Clasp (지대치의 재료와 Clasp 재료 사이의 마찰계수와 원형 clasp의 유지력 추정)

  • Lim, Dong-Chun
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.67-75
    • /
    • 1999
  • The purpose of this study is to evaluate the friction coefficients between abutment materials and clasp materials, and to an estimation formula for retention force. The coefficients of friction between three clasp materials and four abutment materials were measured under various conditions, polished and sandblasted and wet and dry. The measurement was repeated for each combination up to a total measurement of 1200 times. Estimation formula for retention force is measured as sum of two terms, which the one time is proportional to the product of friction coefficient ${\mu}$ and undercut u and the other term is proportional to u-squared. Two proportional coefficient were obtained by least square method. The results are as follows: 1. Friction coefficients were ranged from 0.08 to 0.53 under various conditions. 2. Friction coefficients of non-metal abutment materials are greater in wet conditions than dry conditions. 3. Friction coefficients of sandblasted clasp against abutment are greater than that of polished clasp. 4. Clasp retention force can be estimated with the model as F=$F_d(3.0{\mu}u+1.5u^2/h)$ with minor error.

  • PDF

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

임상가를 위한 특집 1 - 지르코니아의 역사 및 이론적 배경

  • No, Gyeong-Ho;Ha, Seung-Ryong;Kim, Seong-Hun
    • The Journal of the Korean dental association
    • /
    • v.47 no.12
    • /
    • pp.798-803
    • /
    • 2009
  • 지르코니아는 물리적 성질이 금속과 가장 가까운 세라믹이며, 색상이 치아와 비슷하여 치과분야에서 사용빈도가 증가하고 있는 재료이다. 지르코니아는 zirconium dioxide 결정체로서, 1975년 Garvie가 'ceramic steer' 이라고 명명하였듯이 기존의 세라믹과 비교하여 뛰어난 물성을 지니고 있다. 즉, 높은 내열성과 낮은 열전도도, 산성에서 알카리성까지 이르는 내화학 안정성, 낮은 열팽창성, 높은 강도 및 경도, 내마모성을 가지고 있기 때문에 이전부터 공업용 재료로 넓게 시용되어 왔다. 지르코니아의 상변 이를 이용한 toughening방법이 Garvie에 의해 제시됨으로서 세라믹의 최대 단점인 취성은 어느 정도 극복할 수 있게 되었고 이를 계기로 금관 및 계속가공 의치, 임플란트 지대주, 인레이, 온레이 등 치과의 여러 분야에 지르코니아를 적용할 수 있게 되었다. 최근에는 임플란트 매식체에 있어서도 그 적용을 시도함으로서 심미치과치료에 있어서 중요한 부분으로 자리 잡고 있다. 현재 지르코니아는 치과용 세라믹 중에서 가장 높은 기계적 물성을 보이기 때문에 구치부 에서의 사용 가능성이 시도되고 있으며, 코어의 두께를 감소시킴으로써 보철 술식에서 필요한 강도 및 심미성 두 마리 토끼를 잡을 수 있도록 많은 연구가 이루어지고 있다. 이에 지르코니아의 역사 및 이론적 배경에 대하여 알아보고자 한다.

  • PDF

Evaluation of clinical status of removable partial dentures (가철성 국소의치의 임상적 상태에 대한 평가)

  • Yang, Dong-Seok;Cho, Uk;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.320-327
    • /
    • 2009
  • Statement of Problem: Although many efforts have been continually made to estimate long term prognosis of removable partial dentures, the complication of removable partial dentures was still found because of inaccurate fabrication procedure and improper maintenance care. Purpose: The purpose of this study was to evaluate the clinical status of removable partial dentures. Material and methods: A total of 112 individuals with 153 removable partial dentures (35 - 87 years, 64 women and 48 men) were examined by intra-oral examination, diagnostic cast and radiographic examination. Results and conclusion: The results of this study were as follows: 1. Length of service of removable partial dentures was $5.3{\pm}4.3$ years (mean), 4.0 years (median). 2. A total of 45 removable partial dentures were considered failures. The loss of 18 abutments of 369 was founded. 3. Type of arch, Kennedy classification and type of opposite dentition were found to have no influence on longevity and success rate of removable partial dentures (P > .05). 4. Most common major connector was the palatal plate in maxilla and the number of lingual bar and linguoplate designed in mandible were similar. 5. The circumferential type retainer was the most commonly used retainer. 6. Sixty-three percent of the class I and II removable partial dentures incorporated indirect retention into the design. 7. Approximately 81% of the removable partial dentures had at least one defect. Excessive wear of posterior teeth (27.9%), lack of integrity (23.2%), lack of stability (22.6%) were frequent defects of removable partial dentures.

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.

The accuracy evaluation of digital surgical stents according to supported type (디지털 수술용 가이드의 지지타입에 따른 정확도 평가)

  • Lee, Junyoun;Yoon, Minho;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.8-16
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the accuracy of surgical stent according to the supported type. Materials and methods: 5 sets of dental models which have tooth supported edentulous area and tooth-tissue supported edentulous area were made. Dental model were scanned with model scanner, and CBCT was taken. CT data and model scan data were overlapped using In2Guide software, implant were virtually planned in the software. Surgical stents are fabricated by 3D printing. The implant fixture were installed using the surgical stent, CBCT were retaken. CBCT before surgery and after surgery were overlapped, and the differences (angle difference, coronal difference, apical difference) were evaluated using statistical analysis. Results: In the assessment of the accuracy of surgical guides according to arch type, there are no statistically significant differences between maxilla and mandible. In the case of support type, tooth supported stents showed lower angle difference and length difference than tooth-tissue supported stents, which are statistically significant. Conclusion: Arch type does not affect the accuracy of surgical stents. But tooth support stents are more accurate than tooth-tissue support stents in the case of angle and length difference.