• Title/Summary/Keyword: 증발율

Search Result 364, Processing Time 0.033 seconds

Climate Aridity/humidity Characteristics in Seoul According to Changes in Temperature and Precipitation Based on RCP 4.5 and 8.5 (RCP 4.5와 8.5에 따른 기온 및 강수량변화를 반영한 서울 기후 건조/습윤특성)

  • Rim, Chang-Soo;Kim, Seong-Yeop
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.5
    • /
    • pp.421-433
    • /
    • 2014
  • In this study, monthly and annual aridity indices which are the ratios of precipitation to potential evapotranspiration in Seoul climate measurement station were analyzed for past 50 years (1961~2010), and the ratio of aridity index simulated by climate change scenarios (RCP 4.5 and 8.5) for each future period (2011~2040, 2041~2070, 2071~2100) to aridity index for the past period (1971~2000) was analyzed. Furthermore, 5 different potential evapotranspiration equations (FAO P-M, Penman, Makkink, Priestley-Taylor, Hargreaves) were applied to analyze the effect of potential evapotranspiration equation on estimating aridity index and aridity index variation ratio (%). The study results indicate that the monthly precipitation, average temperature and potential evapotranspiration were increased in each future period as compared to past period for both RCP 4.5 and RCP 8.5. Furthermore, winter period showed more significant increase of potential evapotranspiration than summer period, but aridity index showed different patterns as compared with potential evapotranspiration reflecting the influence of precipitation. Therefore, it is necessary to make preparation for the increment of winter evapotranspiration in terms of water resources management. The monthly and annual aridity indices based on future climate change scenarios were greatly different according to potential evapotranspiration equations; however, monthly and annual patterns of aridity index variation ratio (%) in the future period as compared to past period were very similar regardless of applied potential evapotranspiration equation.

Reaction Mechanism between BN-sprayed Graphite and Molten Al in Vacuum (질화붕소가 스프레이코팅된 흑연과 용융 알미늄간의 진공에서의 반응기구)

  • 정재인;임병문;문종호;홍재화;강정수;홍재화;강정수;이영백
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.1
    • /
    • pp.39-44
    • /
    • 1994
  • 질화붕소를 스프레이코팅한 흑연과 용융 알미늄간의 진공에서의 반응기구를 여러 가지 분석장치 를 이용하여 조사하였다. 계면에 형성된 화합물층은 잘 정의된 형태를 보였으며 Al4C3 와 Al8B4C7의 혼 합상이 흑연바로 위에 형성되었고 그위는 주로 AIN층으로 이루어져 있었다. 이러한 화합물의 생성과정 과 반응기구를 자유에너지 관점에서 논의하였다. 이러한 방법으로 흑연 보우트를 제조하여 알미늄 증발 에 이용하였을 경우 매우 안정적인 증발 양상을 보였으며 $0.6mu$m/min 이상의 매우 높은 증발율을 얻을 수 있음을 확인하였다. 또한 제조원가가 저렴하고 (TiB2 BN 보우트의 약 1/100)전자빔 증발에 의해 형 성된 피막과 비교하여 손색이 없는 피막을 얻을 수 있어 새로운 저항가열 증발원으로서의 이용 가능성 을 확인하였다.

  • PDF

Application of Heat Balance Model for Determination of Facilities Capacity to Overcome High Temperature in Greenhouses (온실의 고온극복설비 용량 결정을 위한 열평형 모델의 적용)

  • 남상운
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.27-30
    • /
    • 2000
  • 여름철 고온기에 시설 이용율을 높이고 안정적인 생산을 하기 위하여는 적극적인 차광 환기시스템과 증발냉각시스템을 도입하는 것이 필요하다. 이러한 시스템을 도입하기 위하여는 적정 설비용량의 결정이 중요하며, 이는 지역별 외부의 설계 기상자료로부터 구할 수 있다. 차광환기시스템에서 차광율은 작물의 종류에 따라서 결정되어야 하며 따라서, 기븐적으로 결정해야될 설계 인자는 목표온도를 달성하기 위한 필요환기율과 증발냉각시스템 의 분무수량이다. (중략)

  • PDF

Comparison of the Mean Size of Droplets Ejected from Humidifier by Humidifier Type (가습 방식에 따른 가습입자의 평균 입경 비교)

  • 김용현;박현수;최유화
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2002.04a
    • /
    • pp.120-124
    • /
    • 2002
  • 수박, 토마토 등에 널리 적용되는 삽접, 할접, 핀접 등의 접목 방법에서는 접수의 배축이 절단된 상태에서 접목이 이루어진다. 그러므로 상기의 접목 방법이 적용될 때 접수의 위조를 방지하고 접목묘의 활착율을 증대시키려면 접목 초기에 접목묘로부터 증발산이 과도하게 이루어지지 않도록 활착 환경이 조절되어야 한다. 인공광하에서 활착되는 접목묘로부터 증발산을 억제하면서 활착율을 높이려면 활착실 내에서의 상대습도가 90% 이상으로 높게 유지되어야 한다(Kim, 2000). (중략)

  • PDF

Empirical Analysis on the Cooling Load and Evaporation Efficiency of Fogging System in Greenhouses (온실의 냉방부하 및 포그시스템의 증발효율 실험분석)

  • Nam, Sang-Woon;Seo, Dong-Uk;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.147-152
    • /
    • 2015
  • In order to develop the cooling load estimation method in the greenhouse, the cooling load calculation formula based on the heat balance method was constructed and verified by the actual cooling load measured in the fog cooling greenhouse. To examine the ventilation heat transfer in the cooling load calculation formula, we measured ventilation rates in the experimental greenhouse which a cooling system was not operated. The ventilation heat transfer by a heat balance method showed a relatively good agreement. Evaporation efficiencies of the two-fluid fogging system were a range of 0.3 to 0.94, average 0.67, and it showed that they increased as the ventilation rate increased. We measured thermal environments in a fog cooling greenhouse, and calculated cooling load by heat balance equation. Also we calculated evaporative cooling energy by measuring the sprayed amount in the fogging system. And by comparing those two results, we could verify that the calculated and the measured cooling load showed a relatively similar trend. When the cooling load was low, the measured value was slightly larger than calculated, when the cooling load was high, it has been found to be smaller than calculated. In designing the greenhouse cooling system, the capacity of cooling equipment is determined by the maximum cooling load. We have to consider the safety factor when installed capacity is estimated, so a cooling load calculation method presented in this study could be applied to the greenhouse environmental design.

Study on Performance Prediction and Energy Saving of Indirect Evaporative Cooling System (간접식 증발냉각장치의 성능예측과 에너지절약에 관한 연구)

  • Yoo, Seong Yeon;Kim, Tae Ho;Kim, Myung Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.9
    • /
    • pp.743-749
    • /
    • 2015
  • The purpose of this study is to predict the performance of an indirect evaporative cooling system, and to evaluate its energy saving effect when applied to the exhaust heat recovery system of an air-handling unit. We derive the performance correlation of the indirect evaporative cooling system using a plastic heat exchanger based on experimental data obtained in various conditions. We predict the variations in the performance of the system for various return and outdoor air conditioning systems using the obtained correlation. We also analyze the energy saving of the system realized by the exhaust heat recovery using the typical meteorological data for several cities in Korea. The average utilization rate of the sensible cooling system for the exhaust heat recovery is 44.3% during summer, while that of the evaporative cooling system is 96.7%. The energy saving of the evaporative cooling system is much higher compared to the sensible cooling system, and was about 3.89 times the value obtained in Seoul.

산지유역의 초과우량 추정 모형

  • 남선우;최은호
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1990.07a
    • /
    • pp.49-52
    • /
    • 1990
  • 강우강도가 큰 집중호우가 지표면에 도달하게 되면 강우량중 상당 부분이 수문학적 손실성분인 침수, 증발산, 차단 및 저류등으로 시간에 따라 분포된다. 이 가운데 지표면에 분포된 식생계 및 낙엽등에 의한 차단(canopy interception effect)과, 지표가 포화시의 증발산(wetted environmental evapotranspiration) 및 각종 저류, 즉 지표면 저류(depression storage), 지표토양층에의 저류(retention storage) 성분 등을 들 수 있으며 이들 각 손실성분은 직접유출로 나타나는 초과우량의 발생시간을 지체시켜 주는 역할을 하나 차단성분 및 저류성분은 시간이 경과함에 따라 결국은 증발산 또는 침투성분으로 흡수된다. 따라서 침투성분은 초과우량 추정에 매우 큰 영향을 줄 뿐 아니라 지표면 아래의 흙의 변형을 야기시키며, 중간유출 및 지하수유출에 기여 한다. 대부분의 호우사상은 강우초기에 강우강도가 지표 흙의 침수계수(hydraulic conductivity)보다 작기 때문에 모두 각 손실성분에 의해 손실되며, 강우강도가 점차 커져 침수능을 초과하면 지표면에 순간적으로 물이 고이게 되는데 이것을 지표심수(surface ponding)라하고, 강우시작부터 이 때까지가 침수시간(ponding time)이 된다. 이 지표침수가 나타나는 순간이 곧 직접유출 시작 시간으로 볼 수 있을 뿐 아니라, 침수시간은 지표면의 물수지면에서 볼 때 초기손실량 및 침수율 결정에 중요한 인자가 된다. 본 연구에서는 각 손실 성분별로 유역의 제반 특성을 고려하여 구한 매개변수로부터 시간에 대한 손실율을 결정하여 산지 하천유역에 발생하는 부정강우사상(unsteady rainfall)의 초과우량을 추정하는 모델을 유도하였다. 대상유역으로는 현재 건설부에서 수행하고 있는 국제수문개발계획(IHP) 대표시험유역 가운데 평창강 수계내의 장평유역으로서, 본 유역은 자기 우량계 및 자기 수위계가 운용되고 있고, 인접 대관령 측후소로부터 기상자료를 획득, 이용할 수 있는 비교적 분석에 양호한 조건을 지닌 유역이다. 모델의 유도 과정은 대상유역 식생계로 피복된 산지유역임으로, 식생차단 저류효과를 고려해서 지표면의 흙에 도달되는 순강우주상도를 얻고 이로부터 침수시간 및 침투율을 결정해서 초과우량을 산정하는 모델을 유도하였다. 강우 지속시간내 즉, 유역이 완전 포화시의 증발산율의 결정은 Morton 모델로부터, 침수시간 및 침투율 결정은 Green-Ampt 방정식을 부정강우사상에 적용할 수 있도록 수정된 모델을 사용하였으며, 분석에 이용된 호우는 1986 ~ 1987년도 발생된 호우사상 가운데 강우강도 및 총 강우량이 비교적 큰 7개 강우사상을 선정하였다. 각 호우사상별로 손실율울 지표면에서 물수지개념을 이용하여 계산하고 산술지상에 구성시킨 결과는 다음 그림과 같다. 이 그림에서 굵은 실선으로 나타낸 곡선(B. L. R)은 각 손실을 곡선을 시간축에 따라 산술평균한 대표손실율곡선이다. 이 대표손실율곡선은 역지수함수형으로서 곡선식의 유도는 회기분석을 이용하였다. 초과우량 주상도를 얻기 위하여 이 대표손실을 곡선을 관측 강우주상도에 적용시켜 본 결과 식생계에 의한 차단 저류율은 약 6mm/hr 정도인 것으로 나타났으며, 이로 인한 침수시간 지체효과는 1~3시간 정도로서 비교적 그 영향이 큼을 알았다. 또한 각 호우사상별 침수시간 계산 결과 그 변동이 큰 것으로 나타났는데 이는 초기 강우강도에 민감하기 때문인 것으로 판단되낟. 한편 유역 포화시의 증발산율은 우기의 기상자료를 이용하여 구한 결과 0.05 - 0.10 mm/hr 의 범위로서 이로 인한 강우손실량은 큰 의미가 없음을 알았다.

  • PDF

Surface Characterization of Photocatalyst TiO$_2$ (증발법을 이용한 축산분뇨의 고농도 폐수처리 기술의 개발)

  • 이영신
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.69-73
    • /
    • 2000
  • 본 연구에서는 오염부하량 측면에서 매우 심각한 영향을 미치고 있는 축산폐수에 대하여 기존의 문제점 등을 분석하고 기존의 처리 방법들이 처리를 제대로 하고 있지 못하는 원인을 분석하며, 이러한 기존의 방법 이외의 대안으로서 증발법을 이용하여 축산 폐수를 처리하고자 하였으며, 이를 폐수처리라는 차원보다는 폐기물의 재활용이라는 측면에서 퇴비화를 함으로서 오염도를 줄임과 동시에 재활용율을 고양시키고자 하였다.

Separation of Nitric Acid and Acetic Acid from the Waste Acid in LCD Etching Process (LCD 식각폐액으로부터 질산과 초산의 분리)

  • Chun, Hee-Dong;Roh, Yu-Mi;Park, Sung-Kuk;Kim, Ju-Han;Shin, Chang-Hoon;Kim, Ju-Yup;Ahn, Jae-Woo
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.123-128
    • /
    • 2008
  • The waste solution, which was discharged from the recovery process of LCD etching solution, consists of 15 wt% nitric acid and 20 wt% acetic acid. In this study, it was conducted to separate acid individually from the mixed acid by vacuum evaporation under -760 mmHg gauge and at $40^{\circ}C$. We have investigated evaporation behavior of acid as a function of temperature. There have been problems that tiny amount of nitric acid were evaporated simultaneously above $33^{\circ}C$. Thus, efforts were conducted to recover acetic acid by vacuum evaporation with adding $H_2O$, waste mixed acid and 20 g/L NaOH for a curb on evaporation of nitric acid. By adding $H_2O$, evaporation of nitric acid was reduced from 7% to 0.78%. However, it was reduced from 7% to 0.25% by adding mixed acid. In view of the results achieved so far, we may expect to separate the etching solution individually by controlling vacuum conditions.

  • PDF

Numerical analysis according to evaporator type (증발기 형태에 따른 수치적 해석)

  • Kim, Dae Yeong;Kim, Moon Ki;Yun, Hong Sun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.103-103
    • /
    • 2017
  • 증발기의 형태에 따라 수치적 해석을 진행하면서 최적의 효율을 나타낼 수 있는 증발기를 설계하는 것이 중요하다. 증발기의 수치적 해석은 EES 프로그램을 이용하여 진행되었으며, 계산의 검증은 자사의 제품의 성능과 비교하면서 검증하였다. 증발기의 수치적 해석의 구성은 지배방정식과 연속방정식을 이용하여, 냉매의 총괄열전달계수, 관내외벽의 열전도율, 공기의 총괄열전달계수를 이용하여 총괄열전달계수를 계산하였으며, 총괄열전달계수를 이용하여 증발기의 열량을 계산하였다. 증발기의 수치적 해석과 자사 제품 5개의 제품과 비교하였고, 평균적으로 약 10%의 오차율을 보였다. 신뢰성이 확보된 계산식을 이용하여 Fin의 간격, 단위 질량유량, 열 교환 코일 길이, 풍량의 조건을 각각 변동시켜 증발기 열량 비교를 하며 경향성을 고찰하였다. Fin의 간격을 1mm에서 20mm으로 0.5mm 간격으로 변화 시켰을 경우, 핀 간격이 좁으면 공기 유속이 빨라져 열 교환 효율이 낮아지며, 반대로 넓어지면 냉매 유량에 비해 공기 유량이 많기 때문에 열 교환 효율이 낮아진다. 열 교환 코일 길이를 500mm에서 2400mm으로 50mm 간격으로 변화 시켰을 경우, 열 교환 코일 길이가 길어질수록 배관의 마찰력과 냉매의 온도 상승으로 인하여 공기 온도와의 온도 차이가 줄어들어 열 교환 효율은 낮아진다. 풍량을 20cmm에서 400cmm으로 10cmm 간격으로 변화 시켰을 경우, 일정 풍량 이상 올라가면 공기 유속이 빨라져서 열량이 낮아지는 경향을 보인다. 질량유량을 3g/sec에서 174g/sec으로 4.5g/sec 간격으로 변화 시켰을 경우, 질량 유량에 따라 비례적으로 열량이 높아지는 경향을 보이다가 일정 질량 유량 이상에서는 공기 풍량에 비해 냉매 유량이 많기 때문에 반비례적으로 열량이 낮아진다. 이처럼 증발기의 설계는 Fin 간격, 열 교환 코일 길이, 풍량, 질량유량 등을 복합적으로 고려하여 증발기 설계를 해야 하며, 저장고의 크기, 부하, 사용목적에 따라 최적화된 증발기를 설계하여야 한다.

  • PDF