• Title/Summary/Keyword: 증발수 온도

Search Result 487, Processing Time 0.027 seconds

Effects of Evaporation Water Flow Rate on the Performance of an Indirect Evaporative Cooler (증발수 유량이 간접 증발식 냉각기 성능에 미치는 영향)

  • Choo, Hyun-Seon;Lee, Kwan-Soo;Lee, Dea-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.714-721
    • /
    • 2006
  • In evaporative cooling applications, the evaporation water is supplied usually sufficiently larger than the amount evaporated to enlarge contact surface between the water and the air. Especially in indirect evaporative coolers, however, if the evaporation water flow rate is excessively large, the evaporative cooling effect is not used for heat absorption from the hot fluid but spent to the sensible cooling of the evaporation water itself. This would result in a decrease in the cooling performance of the indirect evaporative cooler. In this study, the effects of the evaporation water flow rate on the cooling performance are investigated theoretically. The cooling process in an indirect evaporative cooler is modeled into a set of linear differential equations and solved to obtain the exact solutions to the temperatures of the hot fluid, the moist air, and the evaporation water. Based on the exact solutions, it is analyzed how much the cooling performance is affected by the evaporation water flow rate. The results show that the decrease in the cooling effectiveness is substantial even for a small flow rate of the evaporation water and the relative decrease is more serious for a high-performance evaporative cooler.

Pan evaporation modeling using multivariate adaptive regression splines (다변량 적응 회귀 스플라인을 이용한 증발접시 증발량 모델링)

  • Seo, Youngmin;Kim, Sungwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.351-354
    • /
    • 2018
  • 본 연구에서는 일 증발접시 증발량 모델링을 위한 다변량 적응 회귀 스플라인 (multivariate adaptive regression splines, MARS) 모델의 성능을 평가하였다. 모델 입력변수 집합은 부산 관측소 (기상청)로부터 수집된 기상자료를 활용하여 증발접시 증발량과의 상관성이 높은 변수들의 조합으로 구성되었으며, 일사량, 일조시간, 평균지상온도, 최대기온의 조합으로 구성된 세 가지 입력집합이 결정되었다. MARS 모델의 성능은 네 가지의 모델성능평가지표를 활용하여 정량적으로 산출되었으며, 그 결과를 인공신경망 (artificial neural network, ANN) 모델과 비교하였다. 입력변수로서 일사량 및 일조시간을 가지는 Set 1의 경우 MARS1 모델이 ANN1 모델보다 우수한 성능을 나타내었으며, Set 2 (일사량, 일조시간, 평균지상온도)의 경우 ANN2 모델, Set 3 (일사량, 일조시간, 평균지상온도, 최대기온)의 경우 MARS3 모델이 상대적으로 우수한 모델 성능을 나타내었다. 모든 분석 모델들을 비교하였을 때, MARS3, ANN2, ANN3, MARS2, MARS1, ANN1 모델의 순서로 우수한 모델 성능을 나타내었으며, 특히 MARS3 모델은 CE = 0.790, $r^2=0.800$, RMSE = 0.762, MAE = 0.587로서 가장 우수한 일 증발접시 증발량 모델링 성능을 나타내었다. 따라서 본 연구에서 적용한 MARS 모델은 지상관측 기상자료를 활용한 일 증발접시 증발량 모델링에서 효과적인 대안이 될 수 있을 것으로 판단된다.

  • PDF

Performance Characteristics of R744 OTEC Power Cycle with Operation Parameters (운전조건에 따른 R744용 해양온도차 발전 사이클의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.580-585
    • /
    • 2012
  • In this paper, the cycle performance analysis for condensation and evaporation capacity, total work and efficiency of ocean thermal energy conversion power system using R744 ($CO_2$) is presented to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include superheating and subcooling degree, evaporation and condensation temperature, pump and turbine efficiency. The main results were summarized as follows : The evaporation capacity of R744 increases with superheating and subcooling degree, but decreases with the increasing condensation temperature. The total work increases with superheating and subcooling degree of R744, but decreases with the increasing evaporating temperature. And, the efficiency increases with subcooling and superheating degree, but decreases with the increasing condensation temperature. Therefore, superheating and subcooling degree, evaporation and condensation temperature and pump and turbine efficiency of R744 OTEC power system have an effect on the evaporation and condensation capacity, total work and efficiency of this system. With a thorough grasp of these effect, it is necessary to design the OTEC power cycle using R744.

Manufacture of Control and Data Acquisition System of Centrifugal Thin Film Evaporator(Centri-Therm, CT-1B) by Computer (컴퓨터를 이용한 원심식 박막증발기의 제어 및 자료 수집 시스템의 제작)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Park, Moo-Hyun;Han, Bong-Ho;Bae, Tae-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.479-485
    • /
    • 1990
  • For the automation of a evaporation process, computer based evaporation system was built and applied to acquisition of the process variables with an centrifugal thin film evaporator(Centri-Therm, CT-1B). Controls of the process conditions were performed by computer system for pressure, feeding rate, steam, evaporation temperature and flow rate of cooling water. The data acquisitions were also performed by computer system for the changes in the concentration and temperature readings for steam, evaporation and cooling water at the both inlet and outlet. The control and the acquisition variables were collected through the interface device and analyzed by programs using the PASCAL language. To control the feeding rate during the concentration process, inverter was used. The cooling water for the vapor condensation was controlled by the valve controller and should be supplied with the flow rate of 125 kg/h. The maximum vapor condensation rate was 41.7kg/h at the feeding rate of 125 kg/h.

  • PDF

Characteristics of Heat Transfer in a Heat pipe Controlled by Solenoid Valve (전자 밸브에 의해서 제어되는 히트파이프의 전열 특성)

  • Jun, C.H.;Jang, Y.S.;Kim, O.G.
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.103-111
    • /
    • 1997
  • The purpose of this research is the study of characteristics of heat transfer in a heat pipe controlled by solenoid valve. A solenoid valve located to the adiabatic section between evaporator and condenser of heat pipe was used to control the valve action for effective energy transfer of the industrial exchanger machine. By the results presented in this study temperature difference between evaporator and condenser increases with increasing the temperature frequency and with decreasing the temperature amplitude. When inclination angle and flow rate of cooling water increases, the temperature amplitude is reached to the steady state rapidly with increasing the temperature frequncy.

  • PDF

Effects of flow direction on the performance of an indirect evaporative cooler (유동 방향이 간접 증발식 냉각기 성능에 미치는 영향)

  • Choo, Hyun-Seon;Lee, Kwan-Soo;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.743-748
    • /
    • 2006
  • Ren et al. analyzed the performance of the indirect evaporative cooler according to the direction of the flow considering evaporation water flow and wetness. However the effect of NTU of each channel on the performance of the indirect evaporative cooler according to the direction of the flow was not analyzed exactly. In this study the effect of the direction of the flow on the Indirect evaporative cooling performance changing NTU of each channel are investigated theoretically. The cooling process of the indirect evaporative cooler by flow direction is modeled into a set of linear differential equations and solved to obtain the exact solutions to the temperatures of the hot fluid, the moist air, and evaporation water. Based on the exact solution in the case of different NTU of each channel, we study the change of the distribution of the temperature according to each flow direction and at the same time analyze the effect of the flow direction on the cooling performance.

  • PDF

Development of Temperature Control Technology of Root Zone using Evaporative Cooling Methods in the Strawberry Hydroponics (증발 냉각방식을 이용한 딸기 수경재배의 배지 온도조절 기술 개발)

  • Kim, Ki-Dong;Ha, Yu-Shin;Lee, Ki-Myung;Park, Dae-Heum;Kwon, Soon-Gu;Park, Jong-Min;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.183-188
    • /
    • 2010
  • It is necessary to develop an efficient and affordable cooling technology and apply the practical system to rural farmhouse, control to adequate growth environment by adjusting temperature of root zone. A study on managing medium temperature of the hydroponics for strawberry cultivation was conducted and feasible evaporative cooling system for the media cooling were as follows: Characteristics of temperature drop were investigated for the evaporative cooling devices using microporous film duct, felt mulching on media surface, and water permeable sheet in culture tank. The evaporative device with water permeable sheet in culture tank was the most efficient and economic on media cooling system.

The Relationship between Affinity of Membrane and Optimum Operation Conditions in the Pervaporation of Aqueous Ethanol (에탄올 수용액의 투과증발에 있어서 막의 친화성과 최적 조업조건의 관계)

  • 전종기;명완재;임선기
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.34-43
    • /
    • 1991
  • The relationships between affinity of membranes and optimum operation conditions were investigated in the pervaporation of water(1)/ethanol(2) mixture through cellulose acetate(CA) membranes having more affinity to water and silicone rubber(SR) membranes having more affinity to ethanol. CA and SR membranes were prepared and amount of sorption, sorption selectivity, pervaporation separation factor and pervaporation rate in both of membranes were determined and compared. The effects of downstream pressure were analyzed using Thompson diagram and the sorption and pervaporation characteristics with composition of feed and operation temperature were examined in terms of affinity, activity coefficient, plasticizing effect and activation energy of individual species. In the separation of water through CA membranes, high performance of both pervaporation separation factor (water to ethanol, $[\alpha^2_1]_{PV}$) and pervaporation rate was obtained in the conditions of low downstream pressure, middle range of feed concentration and high temperature. In the separation of ethanol through SR membranes, pervaporation separation factor(ethanol to water, $[\alpha^2_1]_{PV}$) increased with downstream pressure and decreased with concentration of ethanol in feed and operation temperature, while pervaporation rate showed opposite trends to those of ($[\alpha^2_1]_{PV}$).

  • PDF

지하수 및 토양의 온도 관측 자료를 이용한 함양량 산정 기법

  • 구민호;김형수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.83-87
    • /
    • 2001
  • 토양이나 천부 지하수 온도의 장기 관측 자료를 이용하여 함양량 또는 증발산량을 산정하는 온도추적자법의 원리를 소개하였으며, 국가 지하수 관측망의 장기 관측 자료에 본 방법을 적용하여 관측소 주변에서의 수직적인 물의 흐름(flux)을 추정하였다. 20개 충적층 관정의 수온 관측 자료를 분석한 결과, 15개 지역에서는 증발산에 의한 상향(upward) 흐름이, 5개 지역에서는 지하수 함양에 의한 하향(downward) 흐름이 우세하게 발생하는 것으로 나타났다. 본 방법은 수직적인 물의 흐름을 시간 독립적인 정류 상태로 가정하므로 우기에 지하수 함양이 주로 발생하는 국내의 수리지질학적 조건에 잘 부합하지 않지만 함양 지역을 판단하는 방법으로 유용하게 이용될 수 있다.

  • PDF

A Study on the thermal Kinetics for Disposal of Sewage Sludge Using Thermal Wind Drying of One mechanical Power (ONE구동 열풍건조시스템을 이용한 하수슬러지 감량화를 위한 열적거동 연구)

  • Bae, Hae-Ryong;Ha, Sang-An
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.2
    • /
    • pp.74-84
    • /
    • 2005
  • The objectives of this study was to investigate the improvement of thermal kinetics for disposal of sewage sludge using thermal wind drying. The operational parameters varied are the temperature of $130{\sim}170^{\circ}C$ and evaporation velocity WD. Important parameters effect on thermal kinetics for evaporation of water in sewage sludge studied include the drying time, water content of sewage sludge, solids amount of sewage sludge(TS%) by the varied temperature. The saturation point of water evaporation was observed at the drying time of 60 min in conditions of drying temperature $170^{\circ}C$ and drying time of 120 min by drying temperature $130^{\circ}C$ and WD=0.95 m/s. Operation at drying temperature of $170^{\circ}C$ led to higher rate of evaporation than those 130, $150^{\circ}C$ at WD=1.0 m/s and WD=1.0 m/s was higher than WD=0.5 m/s at drying temperature of $130^{\circ}C$.

  • PDF