• Title/Summary/Keyword: 증기흡수

Search Result 88, Processing Time 0.022 seconds

Semiconductor laser-based absorption spectroscopy for monitoring physical vapor deposition process (증기증착 공정 감시를 위한 반도체 레이저 흡수 분광학)

  • 정의창;송규석;차형기
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.2
    • /
    • pp.59-64
    • /
    • 2004
  • A study on the semiconductor laser-based atomic absorption spectroscopy was performed for monitoring physical vapor deposition process. Gadolinium metal was vaporized with a high evaporation rate by electron beam heating. Real-time atomic absorption spectra were measured by using tunable semiconductor laser beam at 770-794 nm (center wavelength of 780 nm) and its second harmonic at 388-396 nm. Atomic densities of metal vapor can be calculated from the absorption spectra measured. We plot the atomic densities as a function of the electron beam power and compare with the evaporation rates measured by quartz crystal monitor. We demonstrate that the semiconductor laser-based spectroscopic system developed in this study can be applied to monitor the physical vapor deposition process for other metals such as titanium.

Measurement of the transition probabilities at 394.55 nm for physical vapor deposition of Gd (Gd 증기 증착용 394.55 nm 전이선의 전이확률 측정)

  • 고광훈;정의창;김택수;권덕희;노시표;김철중
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.12-13
    • /
    • 2002
  • 원자력 산업용 중성자 흡수체 제조에 사용되는 Gd 금속증기 발생기에 설치할 목적으로 394.55 nm 전이선의 전이확률을 측정한 결과를 보고한다. 증기 증발률을 장시간 동안 일정한 양으로 유지하기 위해서는 증기밀도가 실시간으로 측정되어야 하고, 이를 위해 반도체 레이저를 광원으로 사용하는 원자흡수 분광계를 제작하고 있다. 전자빔 가열로 발생된 원자빔은 가속된 전자빔과의 충돌에 의하여 가열표면의 온도를 알면 설명할 수 있는 일반적인 원자빔 성질과는 매우 다른 특성을 가지고 있다. (중략)

  • PDF

Performance Characteristic of the Compression-Absorption Hybrid Heat Pump Cycles (흡수압축 하이브리드 히트펌프 사이클의 성능특성)

  • Yoon J. I.;Kwon O. K.;Yang Y. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.14-20
    • /
    • 1999
  • This study describes the results of Coefficient of Performance(COP) analysis by cycle simulation for two types of absorption-compression hybrid cycle using the Water/Lithium Bromide solution pair. These types are basic hybrid systems introducing a mechanical compression process into the refrigerant vapor phase of the single effect absorption cycle. In absorption-compression hybrid cycles, coefficient of performance is improved compared with absorption cycle. Hybrid cycle Type 2 is considered as a key technology to support energy utilization system, given its capability of utilizing waste heat to drive system with a high level of efficiency.

  • PDF

Hexane Vapor Concentration Measurement of a Liquid Jet in Crossflow (수직분사제트에서의 헥산 증기농도측정)

  • Oh, Jeong-Seog;Lee, Won-Nam;Lee, Jong-Geun;Santavicca, Dominique A.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.383-389
    • /
    • 2010
  • The vapor concentration of hexane in a liquid spray jet in crossflow was qualitatively measured on the basis of the infrared (IR) extinction techniques. The objectives of the present study are to understand the whole evaporation process from droplet breakup to vapor and to confirm the usefulness of IR emission method in a lab-scale ramjet combustor. From the experimental results, we concluded that hexane vapor mole fraction increased with temperature rise and kept nearly constant during the variation of fuel to air momentum ratio.

  • PDF

Hexane Vapor Concentration Measurement of a Liquid Jet in Crossflow (수직분사제트에서의 헥산 증기농도측정)

  • Oh, Jeong-Seog;Lee, Won-Nam;Lee, Jong-Geun;Santavicca, Dominique A.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.4
    • /
    • pp.25-31
    • /
    • 2010
  • The vapor concentration of hexane in a liquid spray jet in crossflow was qualitatively measured on the basis of the infrared (IR) extinction techniques. The objectives of the present study are to understand the whole evaporation process from droplet breakup to vapor and to confirm the usefulness of IR emission method in a lab-scale ramjet combustor. From the experimental results, we concluded that hexane vapor mole fraction increased with temperature rise and kept nearly constant during the variation of fuel to air momentum ratio.

Development of Absorption fluid with Water-Lithium bromide-Lithium nitrate system (Water-Lithium bromide-Lithium nitrate계 흡수용액 개발)

  • 오영삼;주우성;박달령;조원일;백영순;방효선
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.190-192
    • /
    • 1996
  • 본 연구는 기존의 Water-Lithium Bromide(H2O/LiBr) 용액에 비해 부식성이 낮은 Water-Lithium bromide-Lithium Nitrate계(H2O/LiBr-LiNO3)용액의 용해도, 증기압, 점도, 표면장력 등의 물리적 성질을 조사하였다. 또한 용해도가 가장 큰 최적의 혼합 몰비를 구하여 증기압 및 점도, 표면장력등의 물성을 구함으로써 흡수식 냉온수기용 홉수제 개발의 기본 자료를 확보하였다. 이러한 연구 결과로부터 다성분 Lithium 염 혼합물계로 이루어진 흡수용액 개발의 기초자료로 이용하고자 한다.

  • PDF

Visualization of Marangoni Convection Behavior between Two Surfactant Dropwises in the Process of Steam Absorption (증기흡수시(蒸氣吸收時) 계면활성제액적간(界面活性劑液滴間)에 발생(發生)하는 마랑고니대류거동(對流擧動)의 가시화(可視化))

  • Rie, D.H.;Choi, K.K.;Kashiwagi, T.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.65-71
    • /
    • 1992
  • In most absorption machines, absorption enhancement has been achieved by adding small amount of surfactant additive, which introduced the surface tension difference between absorbent and surfactant droplets in the vapor absorption. The aim of this study is to understand a basic mechanism of Marangoni convection and its effectiveness in the vapor absorption enhancement. In this study, nonflowing aqueous solution of LiBr 60 mass% was exposed to saturated water vapor under the condition that two dropwises surfactant were fixed on the absorbent surface. Our experiments achieved to visualize the enhanced heat and mass transfer phenomena by the effect of Marangoni convection through the laser holographic interferometry. Also, Marangoni convection behavior was obtained by using tracer method.

  • PDF

Noncondensable gas's influence in waster vapor absorption accompanying interfacial disturbance into aqueous solution of LiBr

  • Dong-Ho RIE;Keun-Oh Lee
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.63-70
    • /
    • 1992
  • The aim of this research is to obtain a basic quantitative understanding of the effect of a noncondensable gas on the absorption of water vapor by a $H_2O$ / LiBr combination with n-octanol as the surfactant. Nonflowing aqueous solutions of LiBr (40,45,50 mass%) were exposed to saturated water vapor following the addition of an n-octanol sufactant (0.01 and 0.6 mass%). A small amount of a noncondensable gas (air) was allowed into the absorber (0.03 volume%) and its effect was analyzed by measuring the amount of water vapor absorbed. This study will aid to predict the performance of heat pump and safety operating condition when the noncondensable gas is not allowed in the absorber The results indicate that, in the presence of small amounts of a noncondensable gas, vapor absorption enhancement ratios are less than half o( those obtained under the same experimental conditions when a noncondensable gas is not present (1). The presence of a noncondensable gas causes the partial vapor pressure of air to increase at the vapor / liquid interface, which results in an instability of vapor absorption rate nd. hence, in an inhibition of interfacial disturbance.

  • PDF

Effect of degree of superheat of LiBr aqueous solution on the vapor absorption process for an air-cooled absorption cooling system (공냉형 흡수식 냉방 시스템에서 LiBr 수용액의 과열도가 증기 흡수에 미치는 영향)

  • Kim, S.C.;Oh, M.D.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.122-133
    • /
    • 1997
  • Numerical analysis using finite volume method has been carried out to examine the effect of degree of superheat of LiBr aqueous solution on heat and mass transfer occurred in absorption process. According to the result of this study, it was found that refrigerant vaper was generated at the entrance region of absorber when LiBr aqueous soltion was superheated. As the degree of superheat increases, heat transfer rate increases and vapor absorption rate decreases. The increase in averaged Nusselt and Sherwood numbers could be found as film Reynolds number increases. The larger the degree of superheat, the greater the averaged Nusselt and Sherwood numbers.

  • PDF

흡수식 열펌프 작동유체로서의 나노유체냉매 적용

  • Lee, Jin-Gi;Gang, Yong-Tae
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.37 no.7
    • /
    • pp.4-8
    • /
    • 2008
  • 현재 사용되어지는 냉매에 대한 규제와 에너지 수급불균형의 문제를 해결하기 위해 증기압축식 냉동기의 대체방안중 하나인 흡수식 시스템에 대해 알아보고 흡수식 시스템의 성능향상을 위해 차세대 냉매인 이성분 나노유체의 적용가능성을 제시하고자 한다.

  • PDF