• Title/Summary/Keyword: 증기온도

Search Result 482, Processing Time 0.027 seconds

Design of bilinear observer for Superheater Steam Temperature Estimation (과열기 증기온도 추정을 위한 방선형 관측기의 구성)

  • Lee, Jong-Myeong;Seo, Jin-Heon
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.386-389
    • /
    • 1991
  • The problem of constructing an bilinear observer for use in the control of superheater temperature with desuperheater is considered. The distributed heat input into the superheater is usually not available for use in the observer, and hence is treated as an unknown inputs. The bilinear observer theory for system with unknown inputs is exploited and applied to the problem.

  • PDF

LSTF 주증기배관 파단사고 평가

  • 이규복;손상배
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.260-267
    • /
    • 1996
  • LSTF의 주증기배관 파단사고 실험(RUN SB-SL-01)에 대한 RELAP5/MOD2 해석결과를 제시하고, LSTF의 RUN SB-SL-01 실험결과 중에서 일차측과 이차측 사이의 열전달률에 촛점을 맞추어 증기발생기 이차측 및 일차계통의 압력, 온도 등과 같은 주요변수를 조사하여 RELAP5/MOD2코드의 성능을 평가하였다. 10% 주증기배관파단사고에 관한 최적 평가에서 주요 매개변수의 전체적 추세가 비교적 잘 예측되었다. 원자로압력용기 상층부에서 기포가 발생하는 기간 동안에는 계통 압력에서 작은 차이가 발생함을 알 수 있었는데, 압력차 발생은 가압기가 비어 있거나 원자로압력용기 상층부에서 기포가 발생하기 때문으로 판단된다.

  • PDF

The creep rupture properties on welded joints of Cr-W pipe steels for boiler in advanced thermal power plant (석탄화력발전소 보일러 배관용 Cr-W계 강 용접부의 크리프 파단특성)

  • 이연수;유석현;공병욱;이경운;김정태
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.149-151
    • /
    • 2004
  • 고효율, 대용량의 친환경적이며 경제적인 발전소건설을 위해 초초임계압(USC: Ultra Super Critical) 석탄화력발전소의 건설이 세계적인 추세이다. 이러한 USC발전소는 효율향상을 위해 증기온도와 압력의 상승, 경제적 운용을 위해 부하변동운전 적용확대가 필수적이다. (중략)

  • PDF

일체형원자로 모듈형 증기발생기 자연대류 현상 파악 연구

  • 이상민;김재학;이상원;박군철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.633-638
    • /
    • 1997
  • 중소형 일체형 원자로의 자연대류 실험 및 해석을 통해 일체형 원자로의 자연대류에 의한 잔열제거 기능의 특성 및 피동 안전성을 파악하였다. 이를 위해 일체형 원자로 축소 실험장치를 이용한 자연대류 실증 실험을 수행하였으며, 실험 결과를 RETRAN-03와 COMMIX-1B 코드 해석 결과와 비교, 검증하였다. 실험 결과 일부 증기발생기의 열제거 기능 상실이 발생한 경우에도 노심으로 유입되는 냉각재의 온도가 균일하게 분포하여 피동 잔열 제거가 원만히 일어남을 알 수 있었고 해석 결과와 일치하였다.

  • PDF

The Heat Transfer Performance of a Heat Pipe for Medium-temperature Solar Thermal Storage System (중온 태양열 축열조용 히트파이프의 열이송 성능)

  • Park, Min Kyu;Lee, Jung Ryun;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.69-69
    • /
    • 2011
  • 태양열 발전 플랜트에 사용되는 중고온 범위의 축열조에 고체-액체간 상변화를 수행하는 용융염을 축열물질로 사용하면 액체상 또는 고체상만으로 된 열저장 매체에 비해 축열조의 규모를 축소함과 동시에 축열온도의 균일성 향상에 기여할 수 있다. 중온인 $250{\sim}400^{\circ}C$ 범위에서 이용 가능한 용융염으로는 질산칼륨($KNO_3$), 질산리튬($LiNO_3$)등이 있다. 그러나 이러한 용융염의 가장 큰 단점은 열전도율이 매우 낮다는 것이며, 이로 인해 요구되는 열전달률을 성취하기 위해서는 많은 열접촉면적이 필요하다는 것이다. 이러한 단점을 극복하는 방법을 도입하지 않고서는 축열시스템의 소규화를 성취하는데 큰 효과를 가져올 수 없다. 한편 열수송 성능이 탁월한 히트파이프를 사용하면 열원 및 열침과 축열물질 사이의 열전달 효율을 증가시켜 시스템의 성능 향상과 동시에 소규모화에 기여할 수 있다. 중온 범위 히트파이프의 작동유체로서 다우섬-A(Dowtherm-A)는 $150^{\circ}C$이상 $400^{\circ}C$까지의 범위에서 소수에 불과한 선택적 대안 중 하나이다. 따라서 본 연구에서는 용융염을 사용하는 중온 태양열축열조에 적용 가능한 다우섬-A 히트파이프의 성능을 파악하여 기술적 자료를 제시하고자 하였다. 열원으로는 고온 고압의 과열증기, 그리고 열침으로는 중온의 포화증기를 고려하였다. 용융염 축열조를 수직으로 관통하는 히트파이프는 하단부에서 열원 증기와 열교환 가능하며, 중앙부에서 축열물질과 열교환하고, 상단부에서는 중온 증기와 접촉할 수 있도록 배치하였다. 축열모드에서는 히트파이프의 하단부가 증발부로 작동하고, 중앙부가 응축부로 작동하여 용융염으로 열을 방출하면 용융염의 온도가 상승하고 용융점에 도달하면 액상으로의 상변화가 진행되면서 축열이 활성화된다. 축열모드에서 히트파이프의 상단부는 단열부로 작동한다. 방열과정에서는 히트파이프의 하단부가 단열된 상태이고, 중앙부는 용융염으로부터 열을 받아 증발부로 작동하며, 상단부는 중온 증기로 열을 방출하므로 응축부로 작동한다. 즉, 축열시스템의 작동모드에 따라 하나의 히트파이프에서 증발부, 응축부, 단열부의 위치가 변하게 된다. 특히, 히트파이프의 중앙 부분이 응축부에서 증발부로 전환될 때에도 작동이 보장되려면 내부 작동유체의 연속적인 재순환이 가능해야 하므로, 일반 히트파이프에서와는 달리 초기 작동액체의 충전량을 증발부 전체의 체적보다 더 많이 과충전해야 한다. 이러한 히트파이프의 성능 파악을 위한 실험에서 고려한 변수들은 열부하, 작동액체의 충전률, 작동온도 등이며, 열수송 성능의 지표로서는 유효열전도율과 열저항을 이용하였다. 중온범위에서 적정한 작동온도를 성취하기 위해 실험에서는 전압 조절기로 열부하를 조절하는 동시에 항온조로 응축부의 냉각수 입구 온도를 제어하였다. 하나의 히트파이프에 대해서 최대 1 kW까지의 열부하에서 냉각수 입구 온도를 $40^{\circ}C$에서 $80^{\circ}C$ 범위로 변화시키면 히트파이프 작동온도를 약 $250^{\circ}C$ 내외로 조절 가능하였다. 히트파이프 작동액체 충전률은 윅구조물의 공극 체적을 기준으로 372%에서 420%까지 변화 시켰다. 실험 결과를 토대로 열저항과 유효 열전도율을 각각 입력 열유속, 작동온도, 작동액체 충전률 등의 함수로 제시했다. 동일한 냉각수 온도에서는 충전률이 높을수록 히트파이프의 작동온도가 감소하였다. 열저항 값의 범위는 최소 $0.12^{\circ}C/W$에서 최대 $0.15^{\circ}C/W$까지로 나타났으며 유효 열전도율의 값은 최소 $7,703W/m{\cdot}K$에서 최대 $8,890W/m{\cdot}K$까지 변화했다. 최소 열저항은 충전률 420%인 경우에 나타났는데 이때의 작동온도는 약 $262^{\circ}C$이었다. 히트파이프의 작동한계로서 드라이아웃(dry-out)은 충전률 372%의 경우에 열부하 950 W에서 발생하였으나, 그 이상의 충전률에서는 열부하 1060 W까지 작동한계 발생이 관찰되지 않았다. 실험 결과 본 연구에서의 히트파이프는 중온 태양열 축열조에 적용되어 개당 약 1 kW의 열부하를 이송하면서 축열물질 및 축방열 대상 유동매체와 열교환을 하는데 사용하는데 충분할 것이라 판단된다.

  • PDF

Preparation of TiO2 Nanoparticles from Titanium Tetraisopropoxide Using an Aerosol Microreactor (에어로졸 마이크로반응기에 의한 Titanium Tetraisopropoxide로부터 TiO2 나노입자 제조)

  • Choi, Jae Gil;Park, Kyun Young
    • Korean Chemical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.609-615
    • /
    • 2005
  • $TiO_2$ particles, 30-300 nm in diameter, were prepared by thermal decomposition of titanium tetraisopropoxide (TTIP) using an aerosol microreactor, by which about $1{\mu}l$ of the liquid precursor is injected into an evaporator, 1 cc in volume, and vaporized precursor is then transported by nitrogen as a bolus to a tubular reactor 4 mm in diameter and 35 cm in length. Investigated were the effects of the reactor temperature and the concentration of TTIP vapor on the morphology, particle size distribution and crystalline structure of produced $TiO_2$ particles. With TTIP vapor concentration kept constant at 1 mol%, the reactor temperature was varied from 300 to 500 and $700^{\circ}C$. The primary particle size decreased with increasing the temperature, and the size distributions were mono-modal at 300 and $500^{\circ}C$, but bi-modal at $700^{\circ}C$. The TTIP vapor concentration was increased from 1 to 3.5 and 7 mol%, holding the reactor temperature at $700^{\circ}C$. The bi-modal distribution seen at the concentration of 1 mol% disappeared and the number of particles composing an agglomerate increased at the higher concentrations. These effects of the reactor temperature and the precursor concentration were discussed in comparison with experimental results reported earlier.

Selection of Number of Fans in an Air-Cooled Condenser of a 150 MW Thermal Power Plant according to Ambient Air Temperature (대기온도 변화에 따른 150 MW 화력발전소용 공랭식 복수기 송풍기수 선정)

  • Hwang, Yong-Hoon;Heo, Ki-Moo;Yoon, Sung-Hoon;Moon, Yoon-Jae;Lee, Jae-Heon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.10 no.4
    • /
    • pp.24-28
    • /
    • 2014
  • During this study, number of fan by ambient air temperature that condenser pressure satisfies steam turbine exhaust pressure condition with intervals of $3^{\circ}C$ within the 150 MW thermal power plant site temperature range of $-17.1^{\circ}C$ to $36.7^{\circ}C$ was reviewed. An air cooled condenser changes its operating pressure influenced by cooling air circulation amount by atmospheric temperature and number of fan. For stable power plant operation, these were confirmed to maximize a quantity of air-cooled condenser fans at above or equal from design ambient temperature and to reduce an amount of circulating air to an air cooled condenser by depending on a quantity of fan considering exhaust pressure operation condition of a steam turbine at below design ambient temperature.

  • PDF

Improvement of Boiler Performance on 550 MW Coal Fired Thermal Power Plant via Baffle Plates (다공판 연소가스 유량제어를 통한 석탄화력발전소 보일러 성능 개선)

  • Kim, Chi Ho;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.17 no.1
    • /
    • pp.38-49
    • /
    • 2021
  • In order to increase power plant efficiency, the steam temperature was increased to 610 ℃ which deteriorates the durability of the boiler tube and as the use of low-calorie coal increases the post combustion and delayed combustion phenomenon, the overheating of the final reheater and the tube rupture are becoming frequent. In order to prevent overheating of the final reheater, desuperheater water injection was increased, leading to a decrease in boiler efficiency. In this study install a baffle plate at the back of some overheated tube groups, thereby reduce the temperature of the tube by reducing the amount of combustion gas, and the reduced combustion gas moves to an adjacent place to increase the temperature of other tubes. As a result of the study, the temperature deviation between tubes decreased 1.5. And the heat-reducing injection amount was reduced to 6,929 kg/h and the maximum tube temperature was reduced to 623.4℃ which is 6.6℃ more below than the control standard of 630℃.

에어로졸 반응기 내에서 철 초미립자의 성장 특성

  • 박균영;장희동;최청송
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1997.10a
    • /
    • pp.7-11
    • /
    • 1997
  • 직경 3.5 cm, 길이 1.5 m 의 석영관 내에서 염화제1철 증기를 수소로 환원하여 철 초미립자를 제조하였다. 염화제1철의 증발조건, 염화제1철 증기와 수소의 혼합방법, 반응물의 예비가열온도, 반응온도, 염하제1철의 농도, 반응기내 체류시간이 생성된 철 입자의 크기 및 크기분포에 미치는 영향을 조사하였다. 철 입자의 평균직경은 40-88 cm 이고, 기하표준편차는 1.4 정도로 나타났다. 철 입자들은 자기적 성질에 의해 서로 연결되어 체인을 형성하였으며, 전자회절분석 결과 단결정이었다. 평균입경 55nm 철 입자들의 항자력은 900 Oe, 포화자화값은 130 emu/g 이었다.

  • PDF

Analysis of Electron Swarm Transport Coefficients by Collision Cross Section in Na-He Gas Mixtures (Na-He 혼합증기중에서 충돌단면적에 의한 전자군의 수송계수 해석)

  • 하성철;백수현
    • Electrical & Electronic Materials
    • /
    • v.3 no.2
    • /
    • pp.138-146
    • /
    • 1990
  • 볼츠만 수송방정식에 관한 홀스타인의 식을 사용하여 온도는 273.deg.K, 상대전계의 세기가 1.leq.E/P..leq.30(V/cm Torr)인 때의 Na와 He 단일기체중을 통과하는 전자의 에너지분포함수와 수송계수를 계산하였다. 그리고 전자 이동속도의 결과치를 실험값과 비교하였으며 실험치와 계산치가 일치하도록 충돌단면적을 수정하여 계산에 적용하였다. 이러한 방법으로 Hesms 0.1[eV]-50[eV]까지 Na는 0.1[eV]-5[eV]까지의 에너지범위에서 결정된 운동량변환단면적의 값은 제한된 범위에서 Crompton 및 Nakamura의 값과 거의 일치하였다. 또한 이와 같이하여 계산된 Na와 He 단일기체의 충돌단면적을 이용하여 온도는 273.degK, 상대전계의 세기는 1.leq.E/P$_{o}$ .leq.30(V/cm Torr)의 범위에서 Na-He 혼합증기의 혼합비율을 He:Na는 99.5:0.5, 99:1, 9:1. 1:1로 변화시켜 특성에너지, 평균에너지, 전자이동속도, 전자에너지 분포함수를 게산하였다.

  • PDF