• Title/Summary/Keyword: 증기온도

Search Result 482, Processing Time 0.031 seconds

Comparison of the neural networks with spline interpolation in modelling superheated water (물의 과열증기 모델링에 대한 신경회로망과 스플라인 보간법 비교)

  • Lee, Tae-Hwan;Park, Jin-Hyun;Kim, Bong-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.685-690
    • /
    • 2008
  • In numerically evaluating the thermal performance of the heat exchanger, numerical values of thermodynamic properties such as temperature, pressure, specific volume, enthalpy and entropy are required. But the steam table or diagram itself cannot be directly used without modelling. In this study the applicability of neural networks in modelling superheated water vapor was examined. The multi-layer neural networks consist of an input layer with 2 nodes, two hidden layers with 15 and 25 nodes respectively and an output layer with 3 nodes. Quadratic spline interpolation was also applied for comparison. Neural networks model revealed smaller percentage error compared with spline interpolation. From this result, it is confirmed that the neural networks could be a powerful method in modelling the superheated water vapor.

An Analytical Study on the Condensation of Submerged Vapor Jets in Subcooled Liquids (과냉수에서의 증기응축제트에 대한 해석적 연구)

  • 김기웅;이계복;김환열
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.333-340
    • /
    • 1999
  • A numerical study of turbulent condensing vapor jet submerged in subcooled liquids has been conducted. A physical model of the process is presented employing the locally homogeneous flow approximation of two phase flow in conjunction with a $\kappa$-$\varepsilon$-g model of turbulence properties. In this model the turbulence is represented by differential equations for its kinetic energy and dissipation. A differential equation for the concentration fluctuations is solved and a clipped normal probability distribution function is proposed for the mixture fraction. Effects of steam mass flux, pool temperature and nozzle internal diameter on the condensing vapor jet are also analyzed. The model is evaluated using existing data for turbulent condensing vapor jets. The agreement between the predictions and the available experimental data is good.

  • PDF

A Design Study for Improving Thermal Efficiency of Combined Cycle Power Plants using LNG Cold Energy - Design and Off-design Modelling of Gas-turbine Based Combined Cycle - (LNG 냉열을 이용한 복합발전 플랜트의 성능향상에 관한 연구(I) - 복합화력 발전플랜트의 설계점 및 탈설계점 모델링 -)

  • 오세기;김병일
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.159-165
    • /
    • 1999
  • 복합화력 발전플랜트의 운전에서 특히 하절기의 첨두부하시에 외기온도의 상승으로 인한 가스터빈의 출력 감소를 해결하기 위한 방법으로 LNG 연료가 보유하고 있는 냉열을 이용하여 압축기로 유입되는 공기 온도를 감소시키는 냉각시스템의 개념을 개발하고자 복합화력 발전플랜트에 대한 설계점 및 외기온도 변화에 대한 탈설계점 모델링 연구를 수행하였다. 대상 프랜트는 940 MW 서인천 복합 발전플랜트 모듈의 단위 블록을 선택하였으며 발전플랜트 전용 해석코드인 GateCycle을 이용하여 가스터빈과 증기사이클의 주요 기기 들에 대한 모델을 개발하였다. 개발된 모델의 결과를 대상플랜트의 시운전결과와 비교하여 모델의 적정성을 검증하였다. 출력, 효율, 온도 및 유량 등 주요 설계인자들이 최대 ~1.3%의 상대오차 범위 안에서 만족할 만한 신뢰도를 갖는 것을 확인하였다. 탈설계점 성능해석은 본 논문과 관련한 연구의 주목적인 LNG 냉열에 의한 유입공기 냉각시스템 설계시의 경계변수인 외기온도 증가에 대한 각 사이클의 특성변화를 대상으로 하였다. 종합적으로 외기온도가 증가하면 압축기로 유입되는 공기의 양과 이에 대응하는 소요 연료량이 동시에 감소하므로 연소에 따른 가스터빈의 팽창비가 감소한다. 이로 인하여 외기온도 증가시에 가스터빈 출력감소율은 0.5%/$^{\circ}C$로서 배기가스를 이용하는 증기사이클의 출력감소율 0.2%/$^{\circ}C$에 비해 민감하므로 가스터빈 유입공기의 냉각시스템의 설계는 복합화력발전 플랜트의 효율 향상에 크게 기여할 것으로 예상된다.

  • PDF

Theoretical Analysis on the Factors Affecting the Power Efficiency of the Kalina Cycle (칼리나 사이클의 발전효율에 영향을 미치는 요소에 관한 이론적 해석)

  • Lee, Ki-Woo;Chun, Won-Pyo;Shin, Hyeon-Seung;Park, Byung-Duck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5425-5433
    • /
    • 2014
  • This study examined the effects of the key parameters on the power efficiency of the waste heat power plant using the EES program to obtain data for the design of the 20kW Kalina power plant. The parameters include the ammonia mass fraction, vapor pressure, heat source temperature, and the cooling water temperature. According to the analyses, a lower ammonia mass fraction and a higher vapor pressure increase the efficiency, in general. On the other hand, this study shows that there is a specific region with a very low ammonia mass fraction, where the efficiency decreases with ammonia mass fraction. Regarding the vapor pressure at the turbine inlet, the power efficiency increases with increasing vapor pressure. In addition, it was found that the influence of the vapor pressure on the efficiency increases with increasing ammonia mass fraction. Finally, the optimal condition for the maximum power efficiency is defined in this study, i.e., the maximum efficiency was 15% with a 25bar vapor pressure, $160^{\circ}C$ heat source temperature, $10^{\circ}C$ cooling water temperature, and 0.4 ammonia mass fraction.

Effect of Heating and Steaming Treatments on Residual Resin Content and Color Change of Radiata Pine Juvenile Wood (열처리 및 증기처리 라디에타 파인 유령목의 잔류수지율 및 재색변화)

  • Kim, Su-Won;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.4 s.132
    • /
    • pp.30-37
    • /
    • 2005
  • Heating and Steaming treatments were carried for deresinning and color change of radiata pine juvenile wood. The boards of 20 mm and 30 mm thicknesses were heat-treated at $150^{\circ}C$ and $220^{\circ}C$ for 2, 4 and 6 hours and steamed at $100^{\circ}C$ for 6, 24 and 48 hours. For extracting residual resin in treated boards and measuring wood surface color, alcohol-benzene solution and a portable colorimeter were used, respectively. The board of 20 mm thickness were deresined effectively by heating at over $150^{\circ}C$ for 2 hours or steaming for 6 hours while that of 30 mm thickness by steaming for 48 hours. For the board of 30 mm thickness treatment time was more influencing on deresinning than treatment temperature. The steamed boards showed higher $L^*$ than the heat-treated for both thicknesses. $L^*$ decreased with the increase of treatment temperature and time, but for the board heat-treated at $220^{\circ}C$ it didn't change after 4 hours. The surface color of the boards heat-treated at $220^{\circ}C$ for 4 and 6 hours were obviously changed, but those at $150^{\circ}C$ were not. It was revealed that the core of the heat-treated board was color changed as well as the surface.

Reduction of the Reheater Spray for Coal Fired Thermal Power Plant (석탄화력발전소의 재열저감수 저감방안)

  • Kim, Hyung-Deok;Koh, Churl-Kyun;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.46-50
    • /
    • 2013
  • When four operation parameters are adjusted, the temperature of reheater steam is around the designed operator temperature and the decrease of reheater spray flow rate is achieved. As a result, the decrease of thermal efficiency also can be prevented. To keep the reheater exit temperature on the designed value and decrease the use of reheater spray flow rate, the control of four operation parameters is considered and applied in the operation of a thermal power plant.

  • PDF

Calculation of the amount of excess As charge for the GaAs single crystal growting with the horizontal Bridgman method of single temperature zone(1-T HB) (단일 온도대역 수평 Bridgman(1-T HB) 법에 의한 GaAs 단결정 성장시 As 원소의 초과 유입량 계산)

  • 오명환;주승기
    • Korean Journal of Crystallography
    • /
    • v.7 no.1
    • /
    • pp.64-72
    • /
    • 1996
  • Calculation of the amount of excess arsenic charge has been carried out for the single crystal growth of GaAs with 1-T HB(single temperature zone horizontal Bridgman) method which has no low temperature arsenic zone. Based upon the investigation of the thermochemical properties of the Ga and As system, a general equation for the excess dimension of the ampoule and temperature gradient of the furnace. From this result, a theoretical background of the 1-T HB method has been constructed for the single crystal growth of GaAs.

  • PDF

The study on mechanical properties of PC panel with steam curing condition (증기양생 조건에 따른 터널 PC 패널의 물리적 특성에 관한 연구)

  • Ma, Sang-Joon;Jang, Pil-Sung;Shiin, Jin-Yong;Nam, Kwan-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.1
    • /
    • pp.17-24
    • /
    • 2008
  • Many problems exist in the current cast in place concrete lining used in domestic tunnel construction. Especially, the crack of tunnel lining brings about a social and economic problem. It has a lot of influence on stability of structure and the fine finish of lining. So enormous repair-work and reinforcement of tunnel lining could occur an running out of government's budget. In our country, there are domestic production enterprises which produce a special pre-cast concrete product, but the technical level of them is still far behind compared to developed countries. Also, optimum steam coring method is important for the production of high quality product. But there is no regulation of steam curing method in our country. This study is to investigate the properties of PC panel according to the variation of steam curing conditions such as presteaming time and rate of temperature rise. The result shows that the optimum presteaming time of steam curing method in PC panel is more than 1 hour and the desirable rate of temperature in curing chamber is about $20^{\circ}C/hr$.

  • PDF

Comparative Study on the Efficiency of the Gas Discharge Lasers - Limiting Efficiency of Metal Vapor Lasers - (기체방전 레이저의 효율에 관한 연구 -금속증기레이저의 한계효율-)

  • 이재경
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.47-56
    • /
    • 1993
  • Practical efficiencies of pulsed gas discharge lasers utilizing vaporized Au, Ba, Cu, Fe, Mn, Pb, TI atoms are numerically optimized for a discharge pulse of 30 ns rise time at 5 kHz pulse repetition rate. Calculated optimum operating temperatures are close to the values at which the vapor pressure of each atom is about 1 Torr and are in good agreement with experimental values reported elasewhere. The optimum charging voltage was about 4 kV for all atomic vapor lasers except the TI laser. The calculated maximum efficiencies that have been discussed for possible limiting efficiencies for each laser were considerably higher than the reported experimental values. Especially, they were as high as 6.8% for Mn laser and 15% for Ba laser that were comparable to the 8.5% of copper vapor laser, from which considerably higher efficiencies can be expected for these two lasers experimentally. But, the present calculation shows a very low efficiency of 0.058% and requires an exceptional operating condition for the TI laser.

  • PDF

Study on Properties of EPP Bead Foam (EPP 비드폼의 특성에 관한 연구)

  • Jung, Dong-Won;Lee, Eung-Kee;Park, Chul-B.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.991-997
    • /
    • 2011
  • This paper deals with the basic principles and procedures involved in the steam-chest molding process used for manufacturing expanded polypropylene (EPP) bead foam. Steam-chest molding is an integral process for EPP technology. However, little research has been carried out on the processing conditions for steam-chest molding this process. The characteristics of EPP foam are energy absorption, multiple-impact protection, low weight, structural strength, and durability. In this study, the steam pressure in steam-chest molding was varied to determine the optimum conditions for manufacturing EPP foam. Moreover, annealing was performed after EPP-foam molding to prevent the shrinkage of the steam-molded product. It was possible to verify the mechanism of foam shrinkage by observing the change in weight with time at different annealing temperatures. Moreover, a tensile test and scanning electron microscopy (SEM) analysis were performed to support these experimental results. The dimensional stability of each molded product was investigated at different steam pressures.