• Title/Summary/Keyword: 중재적 시술

Search Result 134, Processing Time 0.025 seconds

Effect of Reducing Scattering Radiation Exposure of Medical Staffs When Additional Shielding is Used in Interventional Radiology (중재적 방사선시술에서 부가 차폐체 사용 시 종사자의 산란선 피폭 감소효과)

  • Kim, Min-Jun;Baek, Kang-Nam;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.629-633
    • /
    • 2021
  • This article is designed to look into the radiation exposure dose to each body part and the shielding effect for workers using an additional shielding to reduce their radiation exposured by scattering radiation which is generated in a space between the operating table and lead curtain during interventional radiology(IR) procedures. After placing a human phantom on the table of SIEMENS' angiography machine, the following measurements were taken, depending on the presence of an additional shield of lead equivalent of 0.25 mmPb, manufactured for this purpose: dose to gonad, dose to an area where the personal dosimeter is placed, and dose to an area of eye lens is located. An ion chamber(chamber volume 1,800 cc) was utilized to measure scattering radiation. The two imaging tests were carried out as follows: fluoroscopy of the abdomen (66 kV, 100 mA, 60 seconds) and of the head (70 kV, 65 mA, 60 seconds); and digital subtraction angiography(DSA) of the abdomen (67 kV, 264 mA, 20 seconds) and of the head (79 kV, 300 mA, 20 seconds). In all the experiments, the shielding efficiency of the gonad position was the largest at 59.8%. In case an additional shielding was used as protection against scattering radiation that came through the operating table and the lead curtain during an IR, the radiation shielding efficiency was estimated to be up to 59.8%, leading to a conclusion that its presence may effectively reduce the radiation exposure dose of medical staffs.

Interventional radiology of Bronchial artery embolization due to massive hemoptysis (대량객혈로 인한 기관지 동맥 색전의 중재적 방사선시술)

  • Min, Byoung-Yun;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.17-24
    • /
    • 2010
  • Hemoptysis which is comparatively common symptom in respiratory disease patients is a clinical symptom which has high risk of death in spite of many curative means. Bronchial tube embolization is a very useful medical procedure when hemoptysis does not stop for treatment of internal medicine or surgery and in addition to the purpose of instant hemostasis, for patients for whom surgical operation is impossible or for the purpose of gaining time to improve the state of the patient before surgical operation. In relation to this, this study is to know of the usefulness of bronchial tube artery embolization. The objects were 60 persons for whom bronchial tube artery embolizations are conducted because of large hemoptysis occurred from March 2007 to December 2009 in J hospital. They had large hemoptysis of 400ml or more per day and 200ml or more at a time or though the quantity of hemoptysis was less than 400ml they did not respond to the treatment of internal medicine for 10 days or longer. The average age was 60.5 years and cause diseases were tuberculosis, bronchiectasis, and pneumonia and lung cancer. Embolus parts were Rt bronchial artery 19 examples, Lt bronchial artery, both bronchial artery, Rt Intercostobronchial artery, and they were the case where embolization for many blood vessels were simultaneously carried out. As embolus materials, PVA (conteour) and microcoil were used. In 76.6% of 60 persons of patients hemorrhage stopped with the lapse of time after the procedure and in 4 examples (6.6) re-embolization was carried out due to re-bleeding after the procedure. Bronchial tube artery embolization has high early success rate and effectively controls hemoptysis in the treatment of hemoptysis and is an effective emergency remedy for hemorrhage due to large hemoptysis and will be a good medical procedure which reduces death rate. In addition, primarily if it is conducted together with the treatment of internal medicine it will be, as an effective curative means for hemorrhage due to large hemoptysis, a good mediate radial rays medical procedure which reduces death rate.

Effects of Healing Beats program on patients' anxiety, stress, systolic blood pressure, heart rate and Bis Index after epidural blocking : A randomized controlled trial (Healing Beats 프로그램이 경막외강차단 시술 후 환자의 불안, 스트레스, 수축기 혈압, 심박동수 및 Bis Index에 미치는 효과 : 무작위대조군)

  • Bae, Ik Lyul;Song, Ji Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.54-65
    • /
    • 2020
  • This randomized pre-post-controlled experimental study determined the effect on patients' anxiety, stress, systolic blood pressure, heart rate and Bis index when the Healing Beats program is applied after epidural blockage. The subjects were selected from the patients who visited the Department of Anesthesiology and Pain for the treatment of epidural blockage and volunteered through the recruitment announcement. A total of 74 sets of data were collected and analyzed with 25 subjects in the experimental group, 24 in the placebo group, and 25 in the control group. The data was analyzed using descriptive statistics, x2-tests, F-tests and repeated measures of ANOVA. As a result of the study, the general characteristics and variables of the experimental group, placebo group, and control group were all the same, and anxiety was measured twice before and after the study. There were significant differences between groups (F=27.175, p<.001), and stress (F=4.78, p<.001), heart rate (F=4.22, p<.001) and the Bis index (F=7.96, p<.001) were analyzed by variance according to population and time. There was a significant difference. However, there was no significant difference in systolic blood pressure (F=1.23, p=.298). In conclusion, the Healing Beats program can be used as an effective and effective intervention for sedation in clinical situations or stressful situations.

Characteristics of Needle Insertion Performance of Automated Biopsy Device for Robotic Needle Insertion Type Intervention: Insertion Depth and Accuracy (로봇 자동화 바늘삽입형 중재시술을 위한 자동화 생검장치의 바늘삽입 특성: 바늘삽입 깊이 및 삽입정확도)

  • Moon, Youngjin;Choi, Jaesoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.565-570
    • /
    • 2016
  • This paper presents the characteristics related to needle insertion of a robotic device for the automated biopsy procedure. The automated biopsy device, a main component of the robotic needle insertion type intervention system, allows performance of the full biopsy procedure, except for anesthesia, without direct handling of a radiologist or a tele-operated control. In this study, the needle length parameters corresponding to various insertion depths and precision for needle insertion of the automated biopsy device, are discussed. There were two combinations of needle length parameters for appropriate needle insertion and motion capture-based measurement was performed; 0.156 mm error for the 90 mm length commanded insertion displacement was measured. The pre-defined goal is a maximum 1 mm error and thus our measured error is within the acceptable range. In the repeatability check, it was also shown that the device can implement a highly accurate insertion.

Extraction of Vessel Width in Coronary Angiography Images (관상동맥 조영영상에서의 혈관 폭 추출)

  • Kim, Seong-Hu;Lee, Ju-Won;Kim, Joo-Ho;Choi, Dae-Seob;Lee, Gun-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.11
    • /
    • pp.2538-2543
    • /
    • 2012
  • The Percutaneous Coronary intervention is a typical way of testing which could be performance to treat a stenosed region by inserting a stent using catheter. In this case, choosing the best stent amongst various kinds of stent for performing an intervention is the most difficult process. For the reason, a width of the blood vessel which is stenosed must be correctly measured to help an operator choose right size of stent. So based on pixel, a width of the blood vessel measured by using the way of Euclidean distance after designing a center-line of vessel from a certain point assigned by operator is shown as a profile in this study. This study would be used as a goof reference for operators when choosing right size of stent.

Comparison of Image Quality and Dose between Intra-Venous and Intra-Arterial Liver Dynamic CT using MDCT (MDCT를 이용한 역동적 간 컴퓨터단층촬영 검사에서 정맥과 동맥 주입법에 따른 영상의 화질 및 선량 비교)

  • Ji-Young, Kim;Ye-Jin, Cho;Hui-Hyeon, Im;Ju-Hyung, Lee;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-129
    • /
    • 2023
  • The purpose of this study was to analyze differences in imaging quality and dose difference between intra-venous (IV) and intra-arterial (IA) liver dynamic computed tomography (CT). Herein, retrospective, blinded analysis was conducted to analyze signal-to-noise and contrast-to-noise ratios in cases of patients who underwent IV or IA liver dynamic CT for transarterial chemoembolization (TACE), an interventional procedure for hepatocellular carcinoma. The dose length product (DLP) value stored in Picture Archive and Communication System (PACS) was used to calculate the effective dose and thereby compare differences in the dose between the two methods. The mean liver and spleen signal to noise ratio (SNR) was greater in IV-liver dynamic CT than in IA-liver dynamic CT; however, contrast to noise ratio (CNR) was higher in IA-liver dynamic CT than in IV-liver dynamic CT. However, there were no differences in DLP and effective dose between the two methods. In conclusion, our findings showed that IA-liver dynamic CT showed a similar effective dose and superior CNR compared with IV-liver dynamic CT. Further studies must analyze 3D angiography CT of the hepatic artery to clearly distinguish the feeding artery, which is the essential step in interventional procedures for hepatocellular carcinoma.

The Clinical Comparative Investigation of Endovascular Treatment Using GDC and Neurosurgical Operation's Decision for Intracranial Aneurysm (뇌동맥류에 대한 방사선학적 중재적 시술과 신경외과학적 수술 선택의 임상적 비교 고찰)

  • Kim Sang Jin;Go Jung Seok;You Sang Jae;Kim Gyeong Sul;Choi Kwang Nam;Lee Yong Woo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.28 no.1
    • /
    • pp.90-96
    • /
    • 2002
  • Purpose : The purpose of this study is to compare and analyze matters related to procedure such as characteristics and conditions etc. of intracranial aneurysm of patients who were treated GDC(Guglielmi Detachable Coil : Endovascular Treatment) and patien

  • PDF

Clinical Outcomes and Prognosis of Patients with Stent Fracture after Successful Drug-Eluting Stent Implantation (관상동맥 약물 방출 스텐트 삽입 후 스텐트 골절에 대한 임상결과 및 예후)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.109-116
    • /
    • 2014
  • Many studies have suggested that in the era of Drug-Eluting Stents(DES) are one of the causes of In-Stent Restenosis(ISR) of Stent Fracture(SF). The present study sought to evaluate clinical characteristics of patients with stent fracture after successful DES implantation. The 4,701 patients were selected for analysis who underwent a follow-up coronary angiography irrespective of ischemic symptoms. The overall incidence of SF was 32 patients(male:female=19:13, Av. age $62.44{\pm}9.8$year, 0.68%). Fractures of Sirolimus-Eluting Stents(SES), Paclitaxel-Eluting Stents(PES), Biolimus A9-Eluting Stents(BES), Everolimus-Eluting Etents(EES), Endothelial Progenitor Cell Capture Stent(EPC) and Zotarolimus-Eluting Stents(ZES) are accounted for 19(59.4%), 9(28.1%), 2(6.3%), 1(3.1%), 1(3.1%) and 0(0%) respectively. SF developed in the left Anterior Dscending(LAD) artery in 16 patients(50%) and in complex(type B2, C) lesions in 25 patients(69.4%). Ten patients were treated with heterogenous DES, the rest being treated with either homogenous DES(3 patients), plain old balloon angioplasty(3 patients), or conservative medical treatment(17 patients). None of the patients with SF suffered from cardiac death during a follow-up period of $32.9{\pm}12.4$ months. The overall rate of DES fracture over up to 3.7 years of follow-up was 0.68% with higher incidence in SES than in PES. SF frequently occurred in the LAD artery and in complex lesions. Of the patients with SF, coronary intervention was performed only when the binary restenosis lesion was significant. During the follow-up, patients with SF have continued on combination antiplatelet therapy. There is a very low rate of major adverse cardiac events(post-detection of SF), especially cardiac death associated with SF.

Percutaneous Transhepatic Removal of Migrated Biliary Stent from a Chronic Biloma Cavity (만성 담즙종 공동 내로 이동한 담도 스텐트의 경피경간적 제거)

  • Hyoung Nam Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.442-447
    • /
    • 2020
  • Iatrogenic foreign bodies are a challenging complication to both the interventional radiologist and patient, resulting in impaired quality of life and substantial financial cost. The case report describes a successful percutaneous transhepatic removal of an intra-abdominal foreign body. A 72-year-old man underwent surgery for placement of a retrievable covered stent for refractory bile leakage after left hemihepatectomy. Three days after placement, stent folding and migration into a chronic biloma cavity occurred via the bile leakage site. By using a balloon catheter technique, the folded stent could be straightened and repositioned into the bile duct to minimize stent-strut injury during retrieval. The interventional approach could be a valid treatment option for intra-abdominal foreign bodies, as well as intravascular foreign bodies. A thorough understanding of devices and techniques can provide the interventional radiologist with valuable information regarding procedural planning and the management of iatrogenic foreign bodies.

Transarterial Coil Embolization in Two Maltese Dogs with Patent Ductus Arteriosus Using a Mini Cobra-tip Angiocatheter (말티스 견에서 시술된 미니코브라 카테터와 코일을 이용한 동맥관 개존증의 치료 2 증례)

  • Han, Dong-Hyun;An, Hyo-Jin;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.740-745
    • /
    • 2010
  • Patent ductus arteiosus (PDA) is the persistent opening of ductus arterious located between pulmonary artery and descending aorta after birth. Although PDA can be occluded by surgical ligation, interventional closure of PDA using various devices is being rapidly replaced to surgical ligation, because of its non-invasive nature of treatment and minimal post-care after treatment. Main problem encountering in interventional treatment in toy breed dogs is vascular inaccessibility due to small size of artery. Although transvenous approach using jugular veins has been developed, this technique requires experienced skill to locate occlude devices into PDA and has high risk of accidental dislodgement of occluding devices (i.e. embolization coils or vascular plugs). Therefore, in this study, we developed a modified technique for coil embolization using mini-angiocatheter with trans-femoral approach in toy breed dogs (< 3.0 kg of body weight). With this modified method, we were successfully treated two toy breed (Maltese) dogs with the left to right shunted PDA.