• Title/Summary/Keyword: 중앙주파수

Search Result 179, Processing Time 0.029 seconds

A Study on the Diagnostic System for Architectural Elements Using Radio Frequency (무선주파수를 응용한 건축부재의 손상자현 시스템에 관한 연구)

  • Kim, Dong Hyun;Choi, Young Wha
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.1-9
    • /
    • 2012
  • Reinforced concrete buildings will be deteriorated as passed time or effect of an earthquake, etc in main elements. In order to manage such cracks, time and efforts, expense, etc, are required. So micro lead switch sensors are embedding or bonding in flexible specimens, and these are smart elements for diagnostic crack damages by external force such as physical load, dynamic load, etc in this study. The monitoring to crack damages are studied using radio frequency system. If load is received on the center of flexible specimens, embedded and bonded lead switch sensors will be destroyed, and these become to send signals of damages at radio frequency system connected with lead switch sensors. This study is fundamental research of the diagnostic system for architectural elements using radio frequency.

Change of isometric contractile force and muscle activity applying ice and hot according to the time on biceps brachii muscle (온열 및 한랭의 적용시간에 따른 상완이두근의 등척성 수축력과 근활성도 변화)

  • Lee, Joon-Hee;Jeon, Jae-Keun
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.459-465
    • /
    • 2012
  • This study has investigated the effect of isometric contractile force and muscle activity applying ice and hot according to the time from the biceps brachii muscle. In this study, 20 university students participants without musculoskeletal and neurological disorders. By applying a hot pack 5 min, 10 min, 20 min and 30 min respectively and ice pack for 5 min, 10 min, and 20 min respectively. After that measurement are skin temperature, contractile force and muscle activity. Skin temperature of the hot and cold 5 min applied that rapidly changing. Increasing the time it takes to apply a variance has been reduced(p<.001). Isometric contractile force was not statistically significant but highest when applying the hot pack 5 minutes and lowest when applying the hot pack 30 minutes(p<.001). Muscle activity and median frequency was highest when applying the hot pack 5 minutes. To analyze the above results, it was found that isometric contractile force and muscle activity changed according to the applying time. These result lead us to the conclusion that this study will be more evidence for changes in muscle contraction to apply hot pack and ice pack on clinic.

Swell Noise Attenuation Using a Cascade of F-X Filter and Median Filter (F-X 필터와 중앙값 필터를 연속적으로 사용한 파랑잡음 제거)

  • Kim, Sookwan;Hong, Jong Kuk
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.199-208
    • /
    • 2012
  • High-amplitude swell noises (HASN) are very difficult to eliminate from the marine seismic data. In this paper, we applied F-X filter and median filter in order to suppress HASN. Test data have been acquired on the northern offshore of the South Shetland Islands in December, 2010. Parts of data have been contaminated by HASN caused by bad weather during the cruise. We applied F-X filter and median filter to test data with HASN. After F-X filtering, most of non-coherent noises and small-amplitude swell noises are eliminated effectively but HASN are still remained significantly. With median filter, HASN was suppressed better than F-X filter, however some of non-coherent noises are still remains. We applied a cascade of two filters and results show HASN and non-coherent noises are suppressed effectively. After the cascade of two filtering, it is possible to define reflection layers clearly on the velocity spectrum and to produce better stacked section with a good signal-to-noise ratio.

Analysis of Sounds from different Impact Points of Golf Driver (골프 드라이버 임팩트 위치에 따른 소리 분석)

  • Kim, Ho Sung;Jung, Dong Keun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2013
  • This study was aimed to evaluate the characteristics of impact sound of golf driver according to impact points of its face. In order to get the consistent impact sounds, the apparatus for free golf ball drop was prepared and used. Timed amplitude patterns and maximum spectral peaks of the impact sounds were variant according to the impact points of driver face. As an alternative method of impact sound analysis, cumulative sum of spectral power (cumsum) was used to distinguish between impact sounds according to the impact positions. From the comparison of frequencies representing 20%, 40%, 60%, 80% of cumsum of impact sound, 40% cumsum frequency of the center of driver face was lower than that of the toe and the heel. This finding suggests that the impact sound from the center of driver face has higher spectral power of low frequency component than that of the toe and heel.

Characteristics of Stacked Probe-Fed Sqare-Ring Microstrip Antenna (적층구조, 프로브 급전방식, 정사각형 링형태 마이크로스트립 안테나 특성에 관한 연구)

  • 이정연;이중근;김성철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.143-152
    • /
    • 2001
  • A method for miniaturization of microstrip patch antenna without degrading its radiation characteristics is investigated in this paper. It involves perforating the patch to form a microstrip square-ring antenna, and it's BW enhancement is investigated numerically and experimentally. A ring geometry introduces additional parameters to the antenna, and those are used to control impedances, resonance frequencies, and bandwidths. For a single square ring antenna, an increase of the size of perforation increases its input impedance, decreases the resonance frequency, and bandwidths. But it affects little on directivity of the antenna. To match the antenna to a transmission line and also enhance its bandwidth, the ring is stacked by a square patch or another square ring. Also numerically simulated results by the IE3D, and experimental data are compared for proof.

  • PDF

A Study on the ZVS Full Bridge Converters using the New Integrated Magnetics Transformer (새론운 복합변압기를 적용한 영전압 풀브릿지 컨버터에 관한 연구)

  • Ahn, Tae-Young;Bong, Sang-Cheol;Kim, Don-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.396-402
    • /
    • 2008
  • This paper presents the structure and performance of a new Integrated magnetics-based transformer, which can be readily adapted to zero-voltage switching full bridge dc-to-dc converters. The proposed transformer features with two paralleled primary windings and a center-tapped secondary winding. The transformer can be fabricated on standard EE or EI cores where the primary and secondary windings are placed on the outer legs while the output filter inductor is wound on the middle leg. The performance of the proposed transformer is demonstrated with a 100 kHz 720 W experimental dc-to-dc converter which recorded a 92% conversion efficiency at 12 V output voltage.

Design and Realization of Metal Waveguide Antenna for Improving Electric field Uniformity (전계분포 균일성 향상을 위한 철사 도파관 안테나 설계 및 제작)

  • Byambaakhuu, Batnairamdal;Hong, Jong-Tak;Cheon, Chang-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1662-1663
    • /
    • 2011
  • 본 논문에서 하지 정맥 지료를 위한 마이크로파 시스템에서 사용될 가열 안테나의 전계 분포를 균일하게 형성시키기 위해 철사 도파관 안테나를 설계 및 제작하였다. 일반적인 도파관 안테나에 경우 안테나 중심 부분에 전계가 가장 세게 분포되어 온도가 다른 곳에 비해 차이가 많이 나므로 인체 피부가 회상을 입힐 위험이 있다. 제안된 철사 도파관 안테나는 끝단에 가느다란 철을 이용하여 전기장을 철사 부분에 집중시켜 안테나 중앙 부분에 집중된 전기장을 분산되도록 설계하였다. 따라서 전기장을 소스로 하는 온도도 균일하게 분포하게 된다. 제안된 철사 도파관 안테나 내부의 전계 분포는 Ansoft 사의 HFSS, 온도 분포는 CST 사의 MWS(Microwave Studio)를 이용하여 시뮬레이션을 하였고, 일반적인 안테나 경우보다 더 균일한 전계와 온도 분포 특성을 보임을 확인하였다. 제작된 철사 안테나는 사용주파수 15GHz에서 -10dB 이하의 반사 손실을 보였다. 또한 안테나 타당성을 검증하기 위해 개구면 앞에 돼지 껍데기를 두고 일정시간 가열하여 일반 안테나와 제안된 철사 도파관 안테나 온도 분포를 비교하였다. 열화상 카메라를 이용한 실험결과 일반 안테나에 경우 중앙과 가장 자리부분 사이에 약 $29^{\circ}C$, 제안된 철사 도파관 안테나에 경우에는 약 $12.5^{\circ}C$의 차이를 보였다. 이를 통해 제안된 철사 도파관 안테나가 전계 분포 균일성 향상에 기여함을 확인하였다.

  • PDF

Analysis of sEMG Median frequency and Ultrasound Image Echodensity of Normal Skeletal Muscle (정상 골격근의 근전도 중앙주파수 및 초음파 영상 밀도 분석)

  • Jeong, Jin-Gyu;Kim, Yong-Nam;Hwang, Tae-Yeun;Lee, Jeong-Woo;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.83-94
    • /
    • 2006
  • Purpose: This study conducts quantitative evaluation or structural and functional characteristics or normal skeletal muscle with ultrasound image and surface electromyography, and is to provide basic materials for utilizing ultrasound image analysis in physical therapy diagnosis and assessment of skeletal muscle. Methods: Measurement of three stages was conducted with 88 normal adults between their twenties and seventies, correlations and differences using collected data according to age and gender were compared and correlations among measured items were analyzed and then the following conclusions were obtained. Results: Analysis of ultrasound image of normal skeletal muscle showed that density, median frequency had the closest relations with age. In addition, it was found that there were high correlations between density explaining structural characteristics of skeletal muscle and median frequency explaining functional characteristics. Conclusion: Analysis of ultrasound image makes complex evaluation of structure and function of skeletal muscle possible when it is connected with functional evaluation method using physical measurement surface electromyography as well as quantitative evaluation of structural changes of skeletal muscle and is effective in complementing physical therapy diagnosis centering around functionality evaluation.

  • PDF

Changes in Spatial Resolution at Position of the Detector in Digital Mammography System (디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화)

  • Kim, Hye-Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.215-222
    • /
    • 2016
  • X-ray mammography is the most effective method for the diagnosis of calcified lesions of various breast diseases. To reduce patient dose and to obtain optimal image required for diagnosis, the performance of the mammography system should be maintained continuously. Because the target (anode) angle of the X-ray tube is measured from the central X-ray, the effective angle can be slightly different in view of the position on the detector, which can result in degrading spatial resolution of the imaging within the field of view. In this study, we measured the MTF to examine spatial resolution for positions on the detector in the digital mammography system. For a tungsten wire of $50{\mu}m$ diameter, the highest spatial frequency was obtained. It meant that a wire diameter for measuring MTF through LSF should be small compared to the pixel size of the detector used in the mammography system. The spatial resolution showed slightly different performance according to positions on the detector. The center position gave the best spatial resolution and positions away from the center showed the degraded performance although the difference of the spatial resolution was small. The effective focal spot size of the full width at half maximum also showed similar result. It concluded that the slightly increase of the effective focal spot size gave the degradation of the spatial resolution for positions on the detector.

A noise reduction structure for vacuum cleaner (진공청소기의 소음저감구조)

  • 박성수;황진성;손진승;최종수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.73-79
    • /
    • 1994
  • (1) 진공청소기의 소음은 팬모타의 회전에 기인하는 유체소음과 진동소음이 주류를 이루며, 여기에 공기의 흡입과 배출에 따른 유체소음등이 복합되어 나타난다. (2) 진공청소기의 소음특성은 각 소음원들의 특성에 따라 주파수대역을 구분할 수 있으며, 기계적 진동음인 500Hz부근에서 peak를 보인다. (3) 소음의 저감을 위하여는 기존에 정립되어 있는 흡음, 차음, 감쇠, 방진, 유압유속감소 등의 기술을 종합적으로 활용하여 제한된 공간내에서 효과를 극대화할 수 있는 구조개발이 필요하며 본 연구에 적용하였다. (4) 본 연구의 '정음유로구조'는 차음효과, 유로길이 증가에 의한 감쇠효과, 흡음효과를 극대화할 수 있는 구조이다. (5) 팬모타의 진동모드는 회전축을 중심으로 원운동을 하며, 진동량은 흡입구와 뒷쪽 베어링부위가 가장 작으므로 회전축에 가까운 곳을 지지하는 것이 방진에 유리하다. (6) 본 구조에서 사용된 케이싱은 484Hz의 고유진동수 성분을 가지며 이는 모타와 공진할 우려가 있다. 이에 공진주파수 성분의 진동량이 가장 작은 전면과 후면의 중앙부를 지지하여 진동을 줄일 수 있었다. (7) 본체소음의 전반적인 저감에 따라 흡입구 등에서 발생하는 공기마찰소음의 영향이 상대적으로 커지며, 따라서 흡입구의 유선형 설계 및 누설소음의 흡음, 차폐 등의 역할이 중요한 관리 요소로 된다.

  • PDF