• Title/Summary/Keyword: 중성자 영상 분석

Search Result 3, Processing Time 0.017 seconds

A Study on the Metallurgical Characteristics for Sand Iron Ingot Reproduced by the Traditional Iron-making Method on Ancient Period under the Neutron Imaging Analysis (중성자 영상 분석을 활용한 고대 제철법 재현 사철강괴의 금속학적 특성 연구)

  • Cho, Sung Mo;Kim, Jong Yul;Sato, Hirotaka;Kim, TaeJoo;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.35 no.6
    • /
    • pp.631-640
    • /
    • 2019
  • The purpose of this study was to compare analytical results of sand iron bars reproduced by the traditional iron-making method through a destructive analysis and a non-destructive analysis. For these studies, we produced two types of samples. One was sample(SI-A), a part of the sand iron bar for destructive analysis. The other was SI-B(9 ㎠) for non-destructive analysis. A metallurgical microscope and scanning electron microscope were used for the destructive analysis, and neutron imaging analysis with the Hokkaido University Neutron Source (HUNS) at Hokkaido University, Japan, was used for the non-destructive analysis. The results obtained by destructive analysis showed that there was ferrite and pearlite of fine crystallite size, and some of these showed Widmanstätten ferrite microstructure grown within the pearlite and coarse ferrite at the edge of the specimen. The results from the neutron imaging analysis showed that there was also ferrite and pearlite with 3 ㎛ α-Fe of BCC structure. Based on these results, neutron imaging analysis is capable of identifying material characteristics without destroying the object and obtaining optimal research results when applying it to objects of cultural heritage.

영상 및 방사선 신호를 이용한 핵물질 감시시스템

  • 송대용;이상윤;하장호;고원일;김호동;이태훈
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.305-305
    • /
    • 2004
  • 핵물질을 취급하는 시설에서는 핵물질 안전조치 목적의 달성, 즉 핵물질의 군사적 전용 및 도난을 방지하기 위한 하나의 수단으로서 핵물질의 취급 및 이동을 감시하기 위한 감시시스템이 요구된다. 이 연구에서는 이러한 요구에 부응하기 위해 시설 내에서 핵물질이 이동 가능한 모든 경로에 중성자 모니터와 카메라 같은 감시 장비를 설치하고, 이들로부터 실시간으로 방사선 신호와 영상 데이터를 취득ㆍ분석하여 핵물질의 거동을 진단할 수 있는 핵물질 감시시스템을 개발하였다.(중략)

  • PDF

Image Comparisons using a Diethylenetriaminetriacetic Acid Derivative and Gd-DTPA (Diethylenetriaminetriacetic acid 유도체와 Gd-DTPA와의 영상비교)

  • Cho, Jung-Keun;Lee, Chai-Ho;Han, Tae-Jong;Lim, Cheong-Hwan;Kim, Jung-Nam;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.210-216
    • /
    • 2008
  • In this study, image comparisons were carried out using a MRI contrast medium which was derived by mixing a polyaminocarboxylic ligand and a gadolinium (III) transition metal which is paramagnetic and has good neutron absorbing capabilities with Gd-DTPA which is currently being used widely in the clinical setting. By using a 1.0T (Harmony, SIEMENS) MR equipment, phantoms of which 100cc of saline was diluted with a diethylenetriaminetriacetic acid derivative and Gd-DTPA were imaged. The amount of diethylenetriaminetriacetic acid and Gd-DTPA which was diluted into the 100cc of saline was 0.05mmol/L, 0.1mmol/L, 0.15mmol/L, 0.2mmol/L, 0.3mmol/L, 0.5mmol/L, 1.0mmol/L, 2.0mmol/L, 3.0mmol/L and 4.9mmol/L respectively. Head coils were used and while fixing the SE pulse sequence and image variable (as TE is 14ms, 1NEX with a 256x201 matrix), the signal intensity and simple contrast ratios according to changing concentrations and TR were compared with various TR at 300ms, 400ms, 500ms, 600ms, 700ms, 800ms, 900ms, 1000ms, 1200ms, 1400ms and 1600ms. According to the comparison results of the signal intensity of the image based on changes in contrast medium concentrations and TR, the differences in signal intensity between the two contrast mediums were found to be small at $1.0{\sim}2.0mmol/L$ when the highest signal intensity was achieved. However, at concentrations of 1.0mmol/L or less, the signal intensity was markedly higher in the Diethylenetriaminetriacetic acid derivative than in the Gd-DTPA complex. It was also found that the differences in the signal intensities demonstrated by the concentrations of the contrast mediums were affected by the TR. Accordingly, the efficacy of the Diethylenetriaminetriacetic acid derivative was shown to be better than the Gd-DTPA and also possible to get the optimum image quality by the use of an appropriate TR with appropriate concentrations of contrast medium.