• Title/Summary/Keyword: 중복하중계수

Search Result 4, Processing Time 0.018 seconds

A Study on the Static Test of Rudder Control System for a Basic Trainer (기본훈련기 방향타 조종장치 정적하중 시험에 관한 연구)

  • Jeon, Chan-Won;Lee, Su-Yong;Gang, Gyu-Seop
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.115-121
    • /
    • 2002
  • This report summarized the static test of the rudder system for the KTX-1 basic trainer. The test loads are applied up to the limit and ultimate loads in a stepping sequence. Test loads and test results matt the strength and stiffness requirements of the rudder control system.. Using #004 full scale structure test airframe.

열하중을 받는 이종재 V-노치 균열의 응력강도계수 해석

  • 문창호;조상봉;김진광;노홍래
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.240-240
    • /
    • 2003
  • V-노치 균열에서 열하중이 작용하는 경우는 비제차형 경계조건의 문제가 되고, 이 조건에 대한 방정식의 일반해를 구하기 위해서 재차형 연립방정식에 대한 일반해(Homogeneous solution)와 비제차형 연립방정식에 대한 특수해(Particular solution)의 두 가지 해를 구할 수 있다. 이들 해는 V-노치 균열에 대한 고유치가 되고 이 고유치가 중복근을 가지게 되는 경우에는 로그항(1n[r])이 나타나게 되고 이 항에 의해서 응력을 무한대로 발산시키므로 이를 대수응력특이성이라 한다. 열하중이 작용할 때 대수응력특이성을 나타내는 로그항의 계수가 영(0)이 되어 대수응력특이성이 사라지게 되므로 V-노치 선단에서의 응력특이성은 고유치와 그에 대한 고유벡터에 의해 결정된다. 본 논문에서는 비정상상태 열하중이 가해지는 등방성 이종재료 내의 V-노치 균열문제에서 패기 각도와 이종재료의 기계적 성질에 의해 결정되는 응력특이성지수를 구하고 이에 대한 응력강도계수를 유한요소해석 프로그램인 ANSYS와 상반일 경로 적분법(RWCIM)을 이용하여 구하였다.

  • PDF

Efficiency of Pile Groups with Arrangement of Piles Using Numerical Analysis (수치해석을 통한 말뚝 배치에 따른 군말뚝 효율 분석)

  • Lee, Kichoel;Shin, Sehee;Kim, Dongwook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.523-531
    • /
    • 2021
  • In general, the foundation refers to a group pile with several single piles connected by an upper structure. However, when a load is applied to pile groups, the range of stress applied to the ground is expanded and overlapped compared with the single pile, so the overall bearing capacity may decrease. This reduction ratio of bearing capacity is referred to as the efficiency of pile groups. Therefore, in this study, the soil composition, the arrangement and spacing of group piles, and the contact characteristics between the ground and piles were set as analysis variables, and the group pile efficiency and individual pile behavior were analyzed. As a result of the analysis, the efficiency of pile groups tends to converge or decrease when the friction coefficients are increased with ground type. Through this, the optimal efficiency of pile groups can be derived. In addition, through the analysis of individual piles, the load ratio of each pile was analyzed when an upper load was applied. In the case of piles located inside group piles, the load was relatively low, and this is considered to have an influence on the internal ground.

Seismic Performance Evaluation of Staggered Wall Structures Using FEMA P695 (FEMA P695를 이용한 격간벽 구조의 내진성능평가)

  • Lee, Joon-Ho;Kang, Hyun-Goo;Lee, Min-Hee;Kim, Jin-Koo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.43-50
    • /
    • 2012
  • The FEMA P695 document proposed a methodology to evaluate the collapse safety of a structure and the validity of the seismic design coefficients. In this study, the seismic performance of six- and twelve-story staggered wall structures with a middle corridor was evaluated based on the FEMA P695 procedure. The analysis results of the prototype structures were compared with those of the structures with an increased coupling beam depth or an increased re-bar ratio of the coupling beams in order to investigate the effect of retrofit. The adjusted collapse margin ratios (ACMR) of the model structures obtained from incremental dynamic analyses turned out to be larger than the specified limit states of an ACMR of 20%, which implies that the analysis model structures have enough strength against design level earthquakes. It was also observed that the increase in the re-bar ratio of the coupling beams between the staggered walls was more effective in increasing the ACMR than an increase in the depth of the coupling beams.