• Title/Summary/Keyword: 중량 손실

Search Result 216, Processing Time 0.024 seconds

A Study on Fire-Resistant Performance of Concrete Using Nano-Silica Perticles (나노 실리카 분말을 혼입한 콘크리트의 내화성능연구)

  • Jo Byung-Wan;Park Jong-Bin;Park Jong-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.247-254
    • /
    • 2005
  • Recently, since the advanced nano technology develops unique physical and chemical properties different from those of the conventional materials. Normal concretes mixed with nano - $SiO_2$ have been studied to improve the fire-resistance with high strength and lower heat conductivity. In this pilot study, the nano-particle contents in the specimens (${\Phi}100{\times}200 mm$) were 0, 2, 4, and $6\%$ by weight of cement, and fire-temperatures $200^{\circ}C$, $500^{\circ}C$, and $800^{\circ}C$ were considered. The results show that as the nano-particle contents increases, the weight loss of concrete gradually decreases, and the compressive strength after fire-attack increases effectively.

Development of calyx-removing unit for non-dried red pepper (홍고추 꼭지 제거장치 개발)

  • 이승규;민영봉;나우정;김영복;송대빈;정효석
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.329-334
    • /
    • 2002
  • 홍고추 꼭지 제거 장치를 설계·제작하고 실험을 통하여 성능을 검증하였다. 꼭지 제거 시 발생되는 최대 손실은 공급량 48g/s에서 15.5%를 나타냈으며 꼭지 중량 비를 감안한다면 실제 최대 손실율은 약 8.7%로 예상된다. 고추 이탈율은 공급량 87g/s에서 최대 35%를 나타냈으며, 꼭지 제거율은 공급량 48g/s에서 최고 66%를 나타냈다. 총 고추 투입량을 기준으로 환산한 꼭지 제거 수율은 최고 55%로 나타나 당초 예상했던 성능과는 차이를 나타냈다. 공급량 48g/s, 꼭지 제거율 66%, 손실을 28%, 1일 작업 시간 8시간을 기준으로 홍고추 꼭지 제거 능력을 계산하면 약 912kg으로 이는 인력에 의한 처리량의 약 1.5배에 해당한다.

  • PDF

A Study on the Basic Properties of Wood Impregnated with Inorganic Compounds (무기물처리 목재의 기초물성에 관한 연구)

  • Kim, Geon Hyoung;Oh, Tae Kyung;Lee, Weon Hee
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.15-21
    • /
    • 2006
  • Composite materials were prepared by impregnating water glass into the wood, followed by soaking in solutions of boric acid or phosphoric acid. The effects of these treatments on the physical and mechanical properties of the specimens and especially on its heat resistance were investigated. 1) Weight Percent Gain (WPG)s increased with increase of concentrations of water glass. However, there was little relationship between treatment temperatures and WPG. Generally, WPGs of double treated specimens were higher than single treated ones. 2) Percent shrinkages in each directions of the specimens treated with water glass had higher value than other specimens. Percent shrinkages of the specimens treated with boric acid or phosphoric acid were decreased as compared with untreated specimen. However, the specimens treated with water glass or phosphoric acid showed very high hygroscopicity. 3) The bending strengths of all specimens treated inorganic substances were slightly decreased. However, the values of compressive strength and hardness of most specimens treated with inorganic substances increased or similar to that of untreated specimen except for a phosphoric acid treated specimens. 4) The specimens had good heat resistance. Weight losses of all specimens treated inorganic substances were about 50~70%. In particular, the specimens treated at $300^{\circ}C$ and $400^{\circ}C$ almost kept their shapes.

Acoustic Study of light weight insulation system on Dash using SEA technique (SEA 기법을 이용한 저중량 대시판넬 흡,차음재 성능에 대한 연구)

  • Lim, Hyo-Suk;Park, Kwang-Seo;Kim, Young-Ho;Kim, In-Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.51-55
    • /
    • 2007
  • In this paper Statistical Energy Analysis has been considered to predict high frequency air borne interior noise. Dash panel Insulation is major part to reduce engine excitation noise. Transmission loss and absorption coefficient are considered to predict dash insulation performance. Transmission lose is derived from coupling loss factor and absorption coefficient is derived from internal damping loss factor. Material Biot properties were used to calculate each loss factors. Insulation geometry thickness distribution was hard to measure, so FeGate software was used to calculate thickness map from CAD drawing. Each predicted transmission losses between conventional insulation and light weight insulation were compared with SEA. Transmission loss measurement was performed to validate each prediction result, and it showed good correlation between prediction and measurement. Finally interior noise prediction was performed and result showed light weight insulation system can reduce 40% weight to keep similar performance with conventional insulation system, even though light weigh insulation system has lower sound transmission loss and higher absorption coefficient than conventional system.

  • PDF

Evaluation of Chloride Attack Resistibility of Heavyweight Concrete Using Copper Slag and Magnetite as Aggregate (동슬래그 및 자철석을 골재로 사용한 중량 콘크리트의 회파블록 적용을 위한 염해저항성 평가)

  • Moon, Hoon;Kim, Ji-Hyun;Lee, Jae-Yong;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.6
    • /
    • pp.483-492
    • /
    • 2017
  • Recently, the coastal area has become the popular place for infrastructure development. To provide a beautiful scenary of costal area to nearby facilities without any hinderance, and also to protect those facilities from the sea water overflow, it is necessary to develop a new type of wave dissipating block, which is a turning wave block. It is noticeable that the top of the turning wave block is flat and thus can provide spaces for various purposes. However, the unit weight of the block decreases due to the presence of pipeline that is installed for turning the direction of the waves. In order to mitigate such problem, a heavyweight concrete needs to be used to increase the resistance against tidal waves. The copper slag and magnetite were used as a source of fine and coarse aggregate, respectively. The 28 day compressive strength of concrete incorporating ordinary and heavyweight aggregate did not show significant differences. It should be noted that the chloride ion penetration resistance was evaluated using NT-BUILD 492 rather than ASTM C 1202 method because concrete incorporating magnetite as a coarse aggregate showed excessive current flow by ASTM C 1202 method. According to the results from NT Build 492 method, which uses the penetration depth of chlorine ions to obtain chloride ion diffusivity, the heavyweight concrete incorporating the copper slag and the magnetite showed the best resistance against the chloride ion penetration. Therefore, it is reasonable to say that heavyweight concrete made with copper slag and magnetite can be used for production of turning wave block.

Evaluation of floor impact sound and airborne sound insulation performance of cross laminated timber slabs and their toppings (구조용 직교 집성판 슬래브와 상부 토핑 조건에 따른 바닥충격음 및 공기전달음 평가)

  • Hyo-Jin Lee;Yeon-Su Ha;Sang-Joon Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.572-583
    • /
    • 2023
  • Demand for wood in construction is increasing worldwide. In Korea, technical reviews of high-rise Cross Laminated Timber (CLT) buildings are under way. In this paper, Floor Impact Sound Insulation Performance (FISIP) and Transmission Loss (TL) of 150 mm thick CLT floor panels made of two domestic species, Larix kaempferi and Pinus densiflora, are investigated. The CLT slabs were tested in reverberation chambers connected vertically. When comparing Single Number Quantity (SNQ) of FISIP of the bare panels, the Larix CLT is 3 dB lower in heavy-weight and 1 dB in light-weight than the Pinus CLT. However, there was no difference when concrete toppings were added to improve the performance. As the concrete toppings became thicker, the heavy-weight was reduced by 9 dB ~ 20 dB, and the light-weight by 20 dB ~ 30 dB. And the analysis of these results with area density has confirmed that the area densities are highly correlated (R2 = 0.94 ~ 0.99) to the FISIP of the CLT. The types of CLT didn't affect the TL. Comparison of theoretical TL values with measured TL values has shown that the frequency characteristics are similar but 8 dB ~ 12 dB lower in measured values. The relationship between the TL and frequency characteristics of the tested CLT slabs was derived by using the correction value.

A Study on the Soil Conversion Factor of Underwater Soils (수중토사의 토량환산계수에 관한 연구)

  • Park, Sung-Sik;Bae, Yeon-Hoi;Moon, Hong-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.7
    • /
    • pp.5-12
    • /
    • 2015
  • In this study, the deposition of dredged soils from domestic rivers is simulated in the laboratory using a small soil box. In the tests, small sand with 0.002-0.85 mm, large sand with 0.85-2 mm, and gravel 4.75-5.6 mm are air or water-pluviated into the box. Such various deposition processes are simulated and their dry densities are measured. While dredging or piling such soils, their volume may change. The loss of such soils is calculated by a soil conversion factor C. The C value was determined as 0.91 for small sand, 0.96 for large sand, and 0.91 for gravel. The drainage through soil piles may occur and result in effective stress increase. This may cause the volume change of soils and in order to consider such effect it is necessary to recalculate C values. As a result, dry density increased by 5-12% when the drainage effect is considered. When the drainage effect is considered, the value of soil conversion factor C was 0.81 for small sand, 0.92 for large sand, and 0.82 for gravel. Eventually, the C value decreased up to 4-12%.

요통재해예방을 위한 작업공정 개선

  • 양성환;이동하;나승훈
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.119-124
    • /
    • 1996
  • 최근 산업재해가 기업의 경영에 직.간접적으로 많은 손실을 끼치고 있는 가운데 협착 등의 재래형 산업재해는 감소하는 한편 용통 등의 근골격계통 직업성 재해가 급격히 증가하고 있는 추세이다. 이는 전공정에서 운반작업은 이루어 지고 있으며, 운반대상물, 기계설비, 작업방법 등이 작업자의 신체조건 을 고려하지 않은 부적절한 설계에 의한 무리한 동작의 유발이 그 원인으로 볼 수 있다. 따라서 본 연구에서는 현장의 데이터를 미국 및 일본의 인력작업기준 으로 한 기계설비의 인간공학적인 설계와 생체역학적인 인체의 요추부하의 분석을 통하여 중량물 취급 기준을 마련하여 작업공정 개선전과 개선후비를 비교 검토하고자 한다.

  • PDF

Study on the Rheological Properties of Acorn Starch(III) -Effect of sucrose on the Rheological Properties of Acorn Starch- (Acorn Starch의 유변학적 성질에 관한 연구(III) -Acorn Starch의 유변학적 성질에 미치는 Surcrose 효과를 중심으로-)

  • 김남희
    • The Korean Journal of Rheology
    • /
    • v.10 no.1
    • /
    • pp.7-13
    • /
    • 1998
  • 중량 평균 분자량이 1.22$\times$106이고 다분산도가 8.90이며 수분과 아밀로오스 함량이 각각 9.35%, 27%인 도토리 전분에 sucrose를 첨가하여 동적 유변학적 특성에 대한 온도와 농도의존성을 고찰하였다. AS(acorn starch)-sucrose 계의 점도는 전단속도가 증가하면 감 소하는 전단담화 현상을 나타내며 sucrose 농도가 증가할수록 점도가 증가하였고, Casson 식에 의해 얻어진 항복치는 sucrose 농도가 증가하면 증가하였다. 저장영률과 손실영률은 sucrose 농도가 증가하면 단일하게 증가하였고 손실 탄성률은 온도가 증가하면 감소하였다. DSC 측정자료를 zipper model에 적용시켜 본 결과 sucrose 농도가 증가할수록 zipper의 수 와 junc-tion zone의 수는 증가했으며 크기는 감소하였다. Sucrose는 전분과 수소결합을 형 성하여 용액내에서 가소제처럼 거동함을 알수있었다.

  • PDF

Effect of Antimicrobial Packaging System on the Freshness-preserving of Zucchinis (천연항균제 함유 포장소재처리에 의한 저장호박의 선도 유지효과)

  • 정순경;조성환
    • Food Science and Preservation
    • /
    • v.8 no.3
    • /
    • pp.274-278
    • /
    • 2001
  • The antimicrobial extracts of Rheum palmatum and Coptis chinensis root as well as grapefruit seed extract were applied to dipping treatment for keeping qualities of zucchinis, respectively, which were then packed in low density polyethylene films incorporated with 1% antimicrobial extracts and stored at 10$\^{C}$. Dipping and packaging in the antimicrobial agents suppressed the growth of putrefactive microorganisms and the decay ratio of zucchinis. In addition, the loss ratio of ascorbic acid content of zucchinis and their weight were decreased during the storage of zucchinis. Consequently, the combined method of dipping and packaging in antimicmbial agents tumid out to be superior to dipping treatment or film-packaging in the view point of decay ratio and the quality control of zucchinis.

  • PDF