• Title/Summary/Keyword: 중량측정법

Search Result 209, Processing Time 0.021 seconds

A Study on the Cleanliness Evaluation Methods for the Selection of Alternative Cleaning Agents (대체 세정제의 선정을 위한 세정성 평가방법 연구)

  • Shin, Jin-Ho;Lee, Jae-Hoon;Bae, Jae-Heum;Lee, Min-Jae;Hwang, In-Gook
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.81-90
    • /
    • 2009
  • In this study various cleaning evaluation methods were tested and comparatively evaluated to help cleaning industry. In order to select alternative cleaning agents objectively and systematically, various cleaning evaluation methods such as gravimetric, optically simulated electron emission (OSEE), contact angle, and analytical instrument methods were employed for cleaning contaminants such as flux, solder and grease. The analytical instruments used in this work were Fourier transform infrared spectroscopy (FTIR), ultraviolet visible spectroscopy (UV-VIS) and high performance liquid chromatography (HPLC). The gravimetric method was able to measure cleaning efficiencies easily and simply, but it was not easy to analyze them precisely because of its limitation in the gravimetric measurement. However, the OSEE technique was able to measure quickly and precisely the clean ability of cleaning agents in comparison with the gravimetric method. The contact angle method was found to be necessary for taking special precaution in its application to the cleaning evaluation due to possible formation of tiny organic film on the substrate surface which might be generated from contaminants and cleaning agents. In case of precision analysis that cannot be done by gravimetric method, fine analytical instruments such as UV-VIS, FTIR and HPLC could be used in analyzing trace amount of flux, solder and grease quantitatively, which were extracted from the surface by special solvents.

Estimating the Weight of Ginseng Using an Image Analysis (영상 분석을 이용한 수삼의 중량추정)

  • Jeong, Seokhoon;Ko, Kuk Won;Lee, Ji-Yeon;Lee, Jinho;Seo, Hyeonseok;Lee, Sangjoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.7
    • /
    • pp.333-338
    • /
    • 2016
  • This study is to estimate proximity without direct measurement of the weight of fresh ginseng. For this work, we developed a ginseng image acquiring instrument and obtained 126 ginseng images using the instrument. Image analysis and parameter extraction process was used C language based Labwindows/CVI development tools and open source library OpenCV. Estimation formula is made by weighing the sample with image analysis of fresh ginseng. We analyzed the correlation between the pixel number and the weight of ginseng using a linear regression approach. It was obtained a strong positive correlation coefficient of 0.9162 with a linearity value.

Uncertainty Characteristics of Diverter for Flowmeter Calibration System (액체용 유량계 교정시스템의 Diverter 불확도 특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.3
    • /
    • pp.50-55
    • /
    • 2008
  • The diverter system is a key component in achieving a high accuracy liquid flow rate standard using a static gravimetric system with a flying start and stop method. The diverter is a moving device used to direct flow alternately along its normal course(by pass) or towards the weighing tank. The time needed for collection into the weighing tank is measured using a timer. So it is important to the diversion period is sufficiently fast and triggering point of timer which is determined the filling time. On this studies show that uncertainty of diverter system for changing diversion speed and triggering point was estimated in accordance with Guide to The Expression of Uncertainty in Measurement(ISO).

Effect of Positive Radial Acceleration and Electroshock on the Serum Protein of Mice(I) (마우스의 혈청단백질에 미치는 양성가속도와 전격의 영향에 관하여(1))

  • 남상열
    • The Korean Journal of Zoology
    • /
    • v.6 no.1
    • /
    • pp.9-14
    • /
    • 1963
  • S.M.계인 마우스♂♀를 정상군과 4개의 실험군 즉 양성가속도(5G-50초간과 11G-50초간 매일 각각 폭로) 및 전격(5volt-2초간과 10 volt 2 초간 매일 각각 전격)군으로 나누어 최소한 22일간 순화시킨 후 여지 전지영동법에 의해서 Albumin/Globulin 바와 단백질분할을 측정하고 또한 혈청 전단백질, 혈색소량, Hematocrit 비, 적혈구포약성 및 간, 신장의 중량을 측정하였다. A/G 와 전단백질은 양성가속도의 G-force 증가와 전격적 증가의 각군이 정확군보다 유의하게 현저히 낮은 치를 나타내고 있다. 간장중량, 혈색소량 및 Hematocrit 비는 또한 정상군보다 양성가속도, 전격적 각 조건하에서 낮은 치를 나타내고 있다. 그러나 신장중량은 현저히 증가된 치를 나타낸다. 양성가속도와 전격적조건군의 간장의 조직학적 소견은 혈관적 변화가 나타나고 그리고 양성가속도에서는 또한 액포가 출현하였다. 적혈구 포약성은 거의 변화가 없었다. 이상의 결과로 미루어보아 상기 두 효과로 인해서 주로 간장기능 즉 단백질대사에 이상을 초래하는 것으로 생각된다.

  • PDF

Comparison of the measurement methods of soil water content by error analysis (토양수분(土壤水分) 함량(含量) 측정방법별(測定方法別) 오차분석(誤差分析)에 의(依)한 비교(比較))

  • Eom, K.C.;Ryu, K.S.;Um, K.T.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.4
    • /
    • pp.367-372
    • /
    • 1988
  • A series of field experiment was conducted to find out error range and to compare precision based on error analysis of soil water content measured with gravimetric, surface & depth neutron and gypsum block methods in a sandy loam soil. The error of soil water content measured with gravimetric (core-sampling), surface and depth neutron method showed quardratic curve, whereas that with gypsum block was exponential curve in relation to soil water content. Within the range of volumetric soil water content from 11 to 33%, the error of soil water content measured with gravimetric, surface neutron, depth neutron and gypsum block method was ranged from 0.28 to 3.49%, 0.71 to 2.63%, 0.52% to 1.01% and 0.05 to 21.89%, respectively. The error of soil water content measured with depth neutron method was lower than those of other methods, when the soil water content was more than 14% in sandy loam soil. The relative number of replicates of soil water measurement for surface neutron, depth neutron and gypsum block method to attain same precision for gravimetric method was 0.6-1.7, 0.07-0.8 and 0.1-125, respectively.

  • PDF

Comparative Evaluation of Measurement Methods for Suspended Particles in Indoor and Outdoor Air (실내ㆍ외 공기중 부유먼지 측정방법 상호간의 비교평가)

  • 백성옥;박지혜;최진수;박상곤
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.37-38
    • /
    • 2002
  • 부유먼지가 인체에 미치는 유해성을 평가하기 위해서는 무엇보다도 공인되어 있고 신뢰성 있는 측정방법이 마련되어 있어야 한다. 대기중 부유먼지의 측정방법에는 여러 가지가 있으나 측정원리의 측면에서는 중량법과 광학적방법으로, 포집유량의 측면에서는 high-volume 과 low-volume으로 구분되어지며 임자의 크기별 포집장치의 부착유무에 따라 입도 분리형과 비분리형으로 구분되어지기도 한다. (중략)

  • PDF

Plant Root Length Density Measurement Using Image Processing (영상 처리를 이용한 식물 뿌리 밀도 측정)

  • Kim, G.Y.;Ryu, K.H.
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.479-486
    • /
    • 1997
  • 식물 뿌리에 대한 지식은 식물-토양 사이의 관계 이해, 토양의 호율적 관리, 식물에 의한 영양분과 수분의 흡수 과정 이해, 그리고 토양 등급 지수를 만드는데 있어서 아주 중요하다 식물 뿌리에 관한 정보를 정량화하기 위하여는 뿌리를 흙으로부터 씻어내고 뿌리의 길이, 표면적, 중량과 같은 식물 뿌리의 특성을 측정하여야 한다 하지만 이렇게 뿌리를 씻어 낸 다음 뿌리의 특성을 측정하는 기존의 방법을 이용할 경우 막대한 시간과 노동력이 필요하여 뿌리에 관한 많은 양의 정보를 얻는데 큰 어려움이 있다. 이 연구에서는 식물 뿌리를 관측하는데 필요한 시간과 노동력을 줄일 수 있는 식물 뿌리 측정법을 세선 작업과 자외선 명암 증진법을 이용한 영상 정보 처리 장치를 바탕으로 하여 개발하였다. 개발된 화상 정보 처리 장치를 이용하여 옥수수 뿌리의 길이를 재었을 때 기존의 뿌리 길이 측정 방법보다 2.5 배 발리 측정할 수 있는 것으로 나타났다.

  • PDF

Theoretical Adjustment of Closed Errors in Traverse Surveying (Traverse 측량에 있어서 개합오차의 이론적 조정법)

  • 이계학;장지원;성수련
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.8 no.2
    • /
    • pp.31-34
    • /
    • 1990
  • In this study, the closed errors appeared in traverse surveying are precisely adjusted in consideration of the weights both observed angle and distance. The results of this study show that the theoretical adjustment is more accurate than the compass rule or the transit rule by distribution of the observed angle errors.

  • PDF

Preparation of Poly(butyl methacrylate) Composite Beads containing Carbon Black by Suspension Polymerization (현탁중합법에 의한 카본블랙을 함유하는 폴리뷰틸메타크릴레이트 복합체 입자의 합성)

  • Moon, Ji-Yeon;Park, Moon-Soo
    • Elastomers and Composites
    • /
    • v.43 no.3
    • /
    • pp.157-165
    • /
    • 2008
  • Suspension polymerization was carried out to synthesize poly(butyl methacrylate) (PBMA) composite particles containing carbon black. Water was selected as a reaction medium, hydrophobic silica as a stabilizer and azobisisobutyronitrile as an initiator. Concentration of stabilizer was varied from 0.67 to 2.55 weight% with respect to the water, and that of initiator was varied from 0.25 to 3.00 weight% with respect to the butyl methacrylate (BMA) monomer. All polymerization reactions were conducted at 75$^{\circ}C$. It is found that stabilizer concentration has no impact on reaction kinetics, while an increase in initiator concentration enhances polymerization reaction rate. Increase of carbon black concentration from 1 to 3 to 5 wt% into PBMA displayed progressive decrease in reaction conversion. The particle diameter of PBMA composite particles containing carbon black was found to be between 5 and 30 ${\mu}m$. Glass transition was determined to range from 23.8 to 24.7$^{\circ}C$, irrespective of variation in the concentration of stabilizer, initiator or carbon black.

Potential of Perchlorate Ion-Selective Electrode in PVC Membrane and Electrode Characteristics by ac Impedance (과염소산 이온선택성 PVC막 전극전위와 임피던스에 의한 전극특성)

  • 김경민;조경섭;강안수
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.49-52
    • /
    • 1998
  • 1. 서론 : 화약이나 고체 충진제, 고체로\ulcorner 추진제의 산화제, slurry blasting agent 및 동물사료의 식품첨가제로 사용되고 있는 과염소산은 발화나 폭발성이 매우 강한 산화제로 정확한 순도를 측정하는 것은 중요하다. 용량분석법과 중량분석법에 비교하여 조작이 간단하고 편리한 과염소산이온의 농도를 직접 측정할 수 있는 PVC막 전극에 대한 많은 연구가 진행되고 있다. (생략)

  • PDF