• Title/Summary/Keyword: 중공 원통

Search Result 31, Processing Time 0.025 seconds

The characteristics of pyrolysis and combustion for a hollow cylindrical solid fuel (중공 원통형 고체연료의 열분해 및 연소특성)

  • 민성기;김호영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.517-527
    • /
    • 1989
  • A theoretical analysis for the characteristics of pyrolysis and combustion of solid fuel was carried out in the present study. The hollow cylindrical combustion model including gas phase and solid fuel at inside and outside respectively was developed for the numerical analysis and parametric studies. The effects of volatile contents in the porous solid fuel and Reynolds number at inlet of gas phase on the characteristics of pyrolysis and combustion such as the radial, axial and time variations of volatile mass flux through porous solid fuel, temperature, mass fractions of gaseous fuel and oxidizer, and flame shape were investigated in the parametric studies. The results of the present study show that the flame produced by the volatiles moves to the downstream of fuel with accelerating velocity with time until extinction is occurred resulting from the completion of pyrolysis. When flame is employed with smaller amount of volatiles content in the solid fuel, the flame sheet exists closer to the inner wall of solid fuel. As Reynolds number at inlet increases, the flame sheet moves to the inner wall due to effect of convection even though the volatiles by pyrolysis increases.

Investigation of the Noise Reduction in the Hollow Cylinder Structure (중공 원통형 구조물의 전달소음 감소 방안 연구)

  • Lee, Sang-Won;Lee, Jong-Kil;Jo, Chi-Yong
    • 대한공업교육학회지
    • /
    • v.36 no.1
    • /
    • pp.115-130
    • /
    • 2011
  • When the hollow cylinder structure moves in underwater with high speed structural can be propagated from the end of the structure to the front side. This noise can reduce the sensitivity of the conformal array which installed in the surface of the cylinder. To reduce this noise propagation it is suggested to install two self-reduction rings at the surrounding of the cylinder which is 500mm in diameter and 840mm in length. The places of the two noise reduction rings are 120mm and 240mm point from the end of the structure. Two noise reduction rings reduced 10.1 % of maximum stress. When outside noise frequency applied to the structure from the 4kZ to 6kHz, 20dB noise reduction was calculated using 6 order polynomial equation. When outside noise frequency also applied to the structure with 200Hz, 500Hz, 900Hz, maximum sound pressure level point moved to the end of the structure. Most conformal sensors are fabricated at the front side of the structure. Based on the simulation results proposed two rings can be reduced noise propagation from the tail of the structure effectively.

Characteristic Analysis of Displacement Behavior of Hollow Rollers with Cross Sectional Area Profiles (중공롤러의 절단면 형상변화에 따른 변형거동 특성해석)

  • Chung, Joon Ki;Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.55-61
    • /
    • 2015
  • In this paper, the displacement behavior characteristic of hollow rollers with various cross sectional area profiles and circular plate for load supporting capacity increment has been presented using a finite element method. The FEM results present that the hollow roller with X-shaped or Y-shaped columns between outer tube, middle tube and inner tube reduces a maximum displacement at the middle length of hollow rollers. And the circular plate, which is inserted at the middle of the hollow roller, is very useful to reduce the maximum displacement of hollow rollers with the plate thickness of 30~40mm. This paper presents the weight vs the maximum displacement ratio in which is represented for the optimized design as a function of a hollow roller total weight. The FEM analyzed results recommend the design model 4, 5 and 6 of hollow rollers for decreasing the ratio of maximum displacement and total weight of hollow rollers.

Characteristics Investigation and Design of the Mandrel for Fiber Optic Acoustic Sensor (광섬유 음향 센서용 맨드릴 설계 및 특성 연구)

  • Lee, Jongkil;Ha, Tae-Hyun;Lee, June-Ho
    • 대한공업교육학회지
    • /
    • v.34 no.2
    • /
    • pp.331-345
    • /
    • 2009
  • In this research Sagnac interferometer three different types of mandrel are suggested and this fiber optic sensor is using in monitoring of electric transformer. Vibration characteristics of those mandrels were analyzed and finally more sensitivity mandrel are suggested. Three different mandrels using in fiber optic sensor are hollow cylinder with outer bump, pure hollow cylinder, hollow cylinder with inner bump. Natural frequencies and mode shapes are investigated using finite element method. Mode shape are considered at the frequency range from 2 kHz to 20 kHz. Fundamental dimensions of the hollow cylinder type's mandrel are 30 mm in outer diameter, 50 mm in length, 1 mm in cylinder thickness, $2mm{\times}2mm$ in bump size. Based on the finite element results, when the outer acoustic frequency is near 11 kHz outer bump type and hollow cylinder can get higher sensitivity. Near 17 kHz outer bump and inner bump mandrel can get higher sensitivity. Near 20 kHz hollow cylinder and inner bump mandrel is useful. This results can be applied to design of fiber optic sensor using in monitoring the electrical transformer. Several MHz of outer acoustic frequency can be easily detected using more sensitive mandrel in pursuing expand this technique.

Optimal Mounts Design for a Rotation Machine on a Flexible Plate (평판지지 회전기계의 최적마운트 설계)

  • Kim, Joon-Yeop;Lee, Si-Bok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.38-47
    • /
    • 1989
  • The optimal mounting system for reciprocating comperssor supported on a flexible is designed. Four short hollow rubber cylinders are used as mounting pads, and so the thickness, diameter, height and location of the rubber mounts are considered as design parameters. The optimal mounts parameters which give the smallest force transmittance, are obtained by Constrained Rosenbrock Method.

  • PDF

Designs of fiber-optic mandrel acoustic sensor with an analytical method (해석적 방법에 의한 멘드릴 광섬유 음향센서의 설계)

  • 임종인
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06e
    • /
    • pp.255-258
    • /
    • 1998
  • 본 연구에서는 해석적인 방법을 사용하여 고감도 멘드릴형 광섬유 음향센서를 설계하고자 하였다. 음향감지부의 형상으로 실린더형 멘드릴 및 중공원통형 층상복합체 멘드릴을 선정하고, 음향감도에 대한 이론식을 유도하여 재질변수 및 형상변수 등에 따른 음향감도를 해석하였다. 또한 해석적 방법 및 유한요소법을 이용한 분석결과를 비교하여 해석적인 방법의 타당성을 검증하였다. 그 결과, 멘드릴의 외경변화에 의한 감도변화 경향만이 다소 차이를 보이고 있으나 그 이외의 재질변수 및 형상변수에 의한 음향감도 변화 경향은 서로 잘 일치하는 것으로 분석되었다.

  • PDF

Hollow tube Prism (중공형 원통 프리즘)

  • Gong, Hong-Jin;Choi, Jin;Park, Young-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.124-125
    • /
    • 2003
  • 레이저 광선이 발명이 된 이래로 레이저 빔을 360도 전 방향으로 발사시키는 광학적 장치의 필요성이 매우 컸으며, 이를 이용한 응용장치가 많이 있다. 그러나, 불행히도 이제까지 레이저 빔을 360도 전 방향으로 발사시키는 광학적인 단일 요소가 개발된 적이 없었다. 이 레이저 빔을 360도 전 방향으로 발사시키는 광학적 장치는 회전거울 혹은 회전 홀로그램을 이용한 것이 고작이었다. 하지만, 이러한 회전식장치는 장치의 복잡성, 회전 모터의 회전축의 오차 등 여러 가지 불편한 점이나, 유지보수의 어려움 등을 가지고 있었다. (중략)

  • PDF

Improvment on the filtration process of foxtail millet Yakju (좁쌀약주의 여과공정 개선에 관한 연구)

  • 강영주;고정삼
    • Food Science and Preservation
    • /
    • v.10 no.4
    • /
    • pp.482-487
    • /
    • 2003
  • The filtration effects of glass membrane filters and hollow fiber membranes with different pore size to prevent the haze of a commercial foxtail millet Yakju were investigated. The most particles(haze precusors) present in the Yakju were removed by using 1.2 $\mu\textrm{m}$ glass membrane filter. In case of using 0.45$\mu\textrm{m}$ hollow fiber membrane system, the permeate flux on the Yakju filtration was calculated to 342.8 lmh. During the 3 month storage at 4$^{\circ}C$ and room temperature for each 48 hrs in turn, alittle fine haze was observed from the Yakju even if it was filtered by using 0.7 $\mu\textrm{m}$ glass membrane filter. Anything of haze was, however, observed from the Yakju filtered by using all of hollow fiber membranes. Therefore, the 0.45$\mu\textrm{m}$ hollow fiber membrane system was effective as a final filtration process of the Yakju.

Numerical Analysis of Viscoelastic Cylinders with Mode I Cracks (점탄성 원통의 모드 I 균열 해석)

  • Sim Woo-Jin;Oh Guen
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.259-269
    • /
    • 2006
  • In this paper, the stress intensity factor, energy release rate and crack opening displacement are computed using the finite element method for axisymmetric viscoelastic cylinders with the penny-shaped and circumferential cracks. The triangular elements with quarter point nodes are used to describe the stress singularity around the crack edge. The analytical solutions are also derived by using the elastic-viscoelastic correspondence principle and compared with the numerical results to show the validity and accuracy of the presented method. Viscoelastic materials are assumed to behave elastically in dilatation and like a three-parameter standard linear solid.

Control of Membrane Fouling in Submerged Membrane Bioreactor(MBR) using Air Scouring (침지형 생물 반응기 공정에서 플럭스 향상을 위한 공기 세척 효과에 관한 연구)

  • Shin, Dong-Hwan;Baek, Byung-Do;Chang, In-Soung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.948-954
    • /
    • 2008
  • Membrane bioreactor(MBR) processes have been widely applied to wastewater treatment for last decades due to its excellent capability of solid-liquid separation. However, membrane fouling was considered as a limiting factor in wide application of the MBR process. Excess aeration into membrane surface is a common way to control membrane fouling in most MBR. However, the excessively supplied air is easily dissipated in the reactor, which results in consuming energy and thus, it should be modified for effective control of membrane fouling. In this study, cylindrical tube was introduced to MBR in order to use the supplied air effectively. Membrane fibers were immersed into the cylindrical tube. This makes the supplied air non-dissipated in the reactor so that membrane fouling could be controlled economically. Two different air supplying method was employed and compared each other; nozzle and porous diffuser which were located just beneath the membrane module. Transmembrane pressure(TMP) was monitored as a function of airflow rate, flux, and ratio of the tube area and cross-sectioned area of membrane fibers(A$_m$/A$_t$). Flow rate of air and liquid was regulated to obtain slug flow in the cylindrical tube. With the same flow of air supply, nozzle was more effective for controlling membrane fouling than porous diffuser. Accumulation of sludge was observed in the tube with the nozzle, if the air was not suppled sufficiently. Reduction of membrane fouling was dependent upon the ratio, A$_m$/A$_t$. For diffuser, membrane fouling was minimized when A$_m$/A$_t$ was 0.27, but 0.55 for nozzle.