• Title/Summary/Keyword: 주파수 측정

Search Result 4,599, Processing Time 0.033 seconds

Precision Measurement of Off-AXIS OTF (비축상 OTF의 정밀측정)

  • 조현모;이윤우;이회윤;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.121-126
    • /
    • 1991
  • The knife-edge scanning type OTF measuring equipment is improved to enhance the accuracy in off-axis OTF measurement and the accuracy of this equipment of evaluated by measuring the OTF of 50 mm plano-convex standard lens developed by SIRA group. Measured MTF values of the standard lens are in good agreement with SIRA results within $\pm$0.02 on axis and % $\pm$0.03 off-axis in 0-100 clmm frequency range except only a few spatial frequencies. Measured PTF values are good agreement with SIRA results within $\pm$$5^{\circ}$.

  • PDF

A study on the simplification of HRTF within low frequency region (저역 주파수 영역에서 HRTF의 간략화에 관한 연구)

  • Lee, Chai-Bong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.581-587
    • /
    • 2010
  • In this study, we investigated the effect of the simplification for low frequency region in Head-Related Transfer Function(HRTF) on the sound localization. For this purpose, HRTF was measured and analyzed. The result in the standard deviation of HRTF showed that the directional dependence of low frequency was smaller than that of high frequency region, which means the possibility of simplification in the low frequency region. Simplification was performed by flattening of the low frequency amplitude characteristics with the insertion of the high-pass filter, whose cutoff frequency is given by boundary frequency. Auditory experiments were performed to evaluate the simplified HRTF. The result showed that direction perception was not influenced by the simplification of the frequency characteristics of HRTF for the error of sound localization. The rate of confusion for the front and back was not affected by the simplification of the frequency characteristics within 1kHz of HRTF. Finally, we made it clear that the sound localization was not affected by the simplification of frequency characteristics of HRTF within 1kHz. The result is expected to be utilized to reduce the size of speech information with no deterioration of the directional characteristics of the speech signal.

반사계를 이용한 헬리콘 플라즈마 밀도측정

  • An, Chan-Yong;Wang, Seon-Jeong;Park, Min;Kim, Seon-Ho;Gu, Dong-Jin;Kim, Seong-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.264-264
    • /
    • 2012
  • 자화된 플라즈마 매질 내부에 진행하는 전자기파중에서 ${\omega}_{ci}$ ${\ll}({\omega}_{ci}{\omega}_{ce})_{1/2}{\ll}{\omega}{\ll}{\omega}_{ce}{\ll}{\omega}_{pe}$의 주파수 대역을 사용하여 헬리콘 방전을 발생시킨다. 수 kW의 RF 출력을 사용하는 헬리콘 플라즈마원은 자기장, 중성가스 압력 및 RF 주파수 등을 포함한 방전 조건에 따라 급격하게 플라즈마 밀도가 증가하고, 유사한 플라즈마 발생원에 비하여 높은 효율을 가진다. 이러한 헬리콘 플라즈마가 높은 이온화 효율을 갖는 원인을 알아보기 위해 반사계로 플라즈마 밀도를 측정하였다. 본 연구에서는 helical 타입의 안텐를 이용하여 직경 15 cm pyrex관 내부에 플라즈마를 발생시켰고, 플라즈마 진단을 위해 33~40 GHz의 주파수로 FMCW방식을 이용한 반사계로 플라즈마 밀도를 측정하였다.

  • PDF

(The Characteristics Study of Cavity Antenna Sensor for GIS Insulation Diagnosis (GIS 절연진단용 Cavity 안테나 센서의 특성 연구)

  • Lee, Chang-Hun;Lee, Chang-Uk;Choi, Eun-Hyuck;Kim, Jung-Bae;Kim, Gi-Chai;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.424-426
    • /
    • 2007
  • 본 연구에서는 UHF 대역의 측정이 가능한 Cavity 안테나를 이용하여 절연진단기술에서의 적용가능성을 검토해 보았다. 제안된 안테나는 유전체 손실이나 급전라인의 손실이 없는 공기를 매질로 하므로, 고출력에 적합하며 고효율을 가진다. 또한 제작이 용이한 구조를 가지므로 대량 생산 시 많은 장점올 가질 것으로 기대된다. 시뮬레이션을 통하여 Cavity 안테나가 0.3 ${\sim}$ 10[GHz] 대역에서는 -10[dB]이하의 Return loss값을 가지는 측정주파수 대역이 약 2.7 ${\sim}$ 10[GHz]로 나타났으며, 0.3 ${\sim}$ 2.5[GHz]의 대역일 경우는 측정 주파수 대역이 약 0.7 ${\sim}$ 2.5[GHz]으로 나타남으로써 대표적인 전력기기인 GIS(Gas Insulated Switchgear : 가스절연개폐장치)에서 UHF 대역을 이용한 절연진단기술에서 사용하는 주파수 대역에서 사용이 가능함을 확인할 수 있었다.

  • PDF

Detection and Analysis of Partial Discharges in Insulation Oil by a Monopole Antenna (마이크로폰을 이용한 코로나 방전의 측정 및 분석)

  • Cho, Hyang-Eun;Park, Dae-Won;Kim, Min-Su;Kil, Gyung-Suk;Cheon, Sang-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 논문에서는 수배전반의 상태진단을 위하여 코로나 방전에 의해 발생하는 음향신호의 측정 및 분석에 대하여 기술하였다. 침-평판 전극계를 제작하여 코로나 방전을 모의하였으며 음향신호의 측정에는 감도 4 mV/Pa, -3 dB의 주파수 대역이 4 Hz~100 kHz인 마이크로폰을 사용하였다. 코로나 방전에 의한 음향신호의 주파수 분석결과, 주파수 성분은 10 kHz~80 kHz에 분포하였으며 20 kHz~40 kHz의 성분이 가장 우세하게 나타났다.

  • PDF

A Robust Target Motion Analysis Algorithm for Discontinuous Frequency Measurements (불연속적인 다중 주파수 측정치에 강인한 표적기동분석 알고리즘)

  • Cheong, Myoung-Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.372-379
    • /
    • 2011
  • Estimating underwater target state variables(position, velocity, course, etc) is necessary to counteract threatening targets. In passive sonar systems, conventional target motion analysis(TMA) techniques using bearing and frequency measurements of an underwater target are widely introduced. However, it is not clear how conventional TMA techniques can be used if some of frequency measurements are unavailable during parts of the scenario, partially unavailable frequency measurements are common in the ocean with complicated acoustic conditions where frequency measurements often come and go. This paper proposes a new TMA algorithm, which is robust to partially unavailable frequency measurements, using the frequency measurements fusion method.

A Study on Ultrasonic Relaxation of Rotational Isomerism in Methy and Ethyl Formates using high - Q Ultrasonic Resonator Method (초음파 공명법에 의한 methyl과 ethyl formate의 회전 이성체에 대한 초음파 완화 현상의 연구)

  • 이명하
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06d
    • /
    • pp.35-39
    • /
    • 1998
  • Methyl과 ethyl formate의 초음파 흡수계수를 0.15-2 MHz의 주파수 범위, 온도 5-3$0^{\circ}C$에 걸쳐 1MHz 이하에서 정확한 초음파 흡수측정이 가능한 광 회절 초음파 공명법을 이용하여 측정하였다.그 결과, cisdhk trans 에 의한 초음파 완화 현상은 전형적인 단일 완화현상을 보였고, 그 스페트럼으로부터 완화주파수와 완화강도를 결정할 수 있었다. 완화 주파수와 완화강도의 온도 의존성으로부터 활성화 에너지(ΔH#)와 에너지 차(ΔH)를 구하였다. 측정된 methyl과 ethyl formate의 활성화 에너지는 각각 9.8과 8.9kcal/mol 이었고, 에너지 차는 각각 2.3 과 2.2kcal/mol로 나타났다

  • PDF

Analysis of the Frequency Properties of Range Measurement System using 900Mhz Band RF (900Mhz 대역 RF를 이용한 거리측정 시스템의 주파수특성 분석)

  • Kim Tae-Soo;Oh Inn-Yeal;Chun Joong-Chang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.997-1000
    • /
    • 2006
  • In this paper, we have used the 900Mha RF band and produced the transmitter-receivers to measure the distance of moving range of a crane. We selected the analog signal of 450Khz middle frequency band of the RF Baseset module, and the property data of phase response is analysed to estimate the range distance. We have earned the good results from the experiment.

  • PDF

A Study on the Grain Moisture Measurement using Microwave Attenuations at Two frequencies (두 개의 주파수에서 마이크로파 감쇄를 이용한 곡물의 함수율 측정에 관한 연구)

  • 김송흡;조경준;김종헌
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.268-271
    • /
    • 2000
  • 본 논문에서는 X-band의 10.5 GHz와 S-band의 2.38 GHz 두가지 주파수를 이용하여 곡물의 함수율 측정을 위한 마이크로파 송수신 장치를 설계 및 제작하였다. 측정 장치들의 핵심부품인 발진기, 송수신 패치안테나와 검파기는 HP EEsof ADS를 이용하여 설계하였으며 하이브리드 MIC형태로 제작하였다. 이 송수신 측정장치를 이용하여 측정된 데이터를 통계분석 프로그램으로 회귀 분석하여 밀도에 민감하지 않은 새로운 보정 모델을 제시하였다. 시료의 출력 전압을 독립변수로 한 함수율 측정 모델을 가지고 함수율의 예측값과 실측값을 비교한 결과 상관계수는 0.9276, 표준오차는 0.975 %로 나타나 산물밀도를 보정하면서 정확도가 높은 벼의 함수율 측정이 가능하였다.

  • PDF

A Study on Improvement of Doppler Frequency Estimation Method in a Weather Radar (기상 레이다에서의 도플러 주파수 추정 방법 개선에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.1999-2005
    • /
    • 2015
  • A wind velocity is measured in a weather radar as well as the strength of return echoes from rain clouds. These wind velocities are obtained through estimation of Doppler frequencies in return signals. This kind of Doppler frequency estimation method is called as a correlation method. It is widely used in most weather radars because of less computation time. However, it may cause serious errors if a spectrum is not symmetric. Therefore, in this paper, it is shown that the improved method using 3rd order phase estimation model yields the more accurate estimation of the average Doppler frequency using various simulated weather data.