• Title/Summary/Keyword: 주파수 종속성

Search Result 37, Processing Time 0.025 seconds

Digital Watermarking based on Wavelet Transform and Singular Value Decomposition(SVD) (웨이블릿 변환과 특이치 분해에 기반한 디지털 워터마킹)

  • 김철기;차의영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6A
    • /
    • pp.602-609
    • /
    • 2002
  • In this paper, we propose an robust invisible watermarking method using wavelet transform and singular value decomposition for the ownership protection. of images. For this method, after we decompose the original image in three level using wavelet transform, we use singular value decomposition based key depended watermark insertion method in the lowest band $LL_3.$ And we also watermark using DCT for extraction of watermark and verification of robustness. In the experiments, we found that it had a good quality and robustness in attack such as compression, image processing, geometric transformation and noises. Especially, we know that this method have very high extraction ratio against nose and JPEG compression. And Digimarc's method can not extract watermark in 80 percent compression ratio of JPEG, but the proposed method can extract well.

LC Trap Filter Design of Single Phase NPC Multi-Level PWM Inverters for Harmonic Reduction (고조파 저감을 위한 단상 NPC 멀티레벨 PWM 인버터의 LC트랩 필터 설계)

  • Kim, Yoon-Ho;Lee, Jae-Hak;Kim, Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.313-320
    • /
    • 2006
  • In this paper, a design approach of LC trap filter for output side harmonic reduction of single phase NPC multilevel inverter is proposed, and THD of the output voltage and harmonic FFT of the output current are analyzed. The proposed filter consists of a conventional LCR filter cascaded with an LC trap filter and it is tuned to inverter switching frequency. A NPC multilevel inverter inverter is used an inverter system for high power application and DSP(TMS320C31) is used for the controller. The effectiveness of the proposed system confirmed through simulation and experimental results.

A Comparison Study on Near-surface High-resolution Seismic Data by Different Source and Geophone Types (진원과 수진기별 천부 고해상도 탄성파 자료 비교 연구)

  • Kim, Hyoung-Soo;Keehm, Young-Seuk
    • Journal of the Korean earth science society
    • /
    • v.32 no.6
    • /
    • pp.674-686
    • /
    • 2011
  • Choosing a seismic source and geophone type including a coupling method can be the most important factor in shallow seismic surveys. We studied the characteristics of seismic signals by analyzing 6 different seismic data sets that collected from several sources and geophone conditions. Geophones attached to weight plate (1.8 kg) can be easily and economically installed on the paved road where geophones with spikes would cause the coupling problem. In addition, experiments in this study revealed that a small handy hammer can be used as a seismic source by striking the paved road to generate the seismic signals within 200 ms two-way travel time. Attaching weight plates to geophones may change the geophone response curve which generally depends on the geophone mass, but the change seems not to give significant differences in the first arrival of refracted wave and in the pattern of reflection events. Consequently, using weight plates on paved roads can be an efficient and cost-saving method in the near-surface high-resolution seismic surveys.

Design of $H_{\infty}$Controller for the inverted pendulum system (도립진자 시스템의 $H_{\infty}$ 제어기 설계)

  • Seo, Kang-Myun;Kang, Moon-Sung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.10
    • /
    • pp.1796-1803
    • /
    • 2006
  • This Paper describes a systematic method for designing the $H_{\infty}$ controller for the inverted pendulum which is a nonlinear and single-input double-outputs system. In particular, the open-loop system is conbined with a pre-filter to shape the open-loop transfer function for the sensitivity function ind the complementary sensitivity function to be kept the desirable frequency characteristics. Consequently, the loop shaping technique of the open-loop transfer function reduces the impacts of the model uncertainties, measurement noises and exogenous disterbances on the dynamic characteristics of the inverted pendulum. The results of simulation and experiment show the efficiency of the proposed control method comparing with conventional PID control method.

The Effect of working Noise Exposure and Military Background on the Hearing Threshold (특수병과의 과거 군 소음 노출이 소음 노출 작업자의 청력에 미치는 영향)

  • Chung, Ho-Keun;Kim, Kyoo-Sang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.2
    • /
    • pp.137-146
    • /
    • 2003
  • Objectives : Impaired hearing is a prevalent occupational hazard, not only in industry, but also in the armed forces. In military life, noise has unusual characteristics, and constitutes a serious hazard to hearing. The aim of this study was to analyze the hearing threshold data in order to compare the hearing loss among shipyard workers, representing different workers, and a military service background. Methods : A cross-sectional audiological survey, combined with a questionnaire study, was conducted on a stratified random sample of 440 shipyard workers, with long-term exposure to noise. The employees were divided into four groups, according to their working and military service backgrounds, in relation to their exposure to noise. Results : As expected, the working and military noise exposure group (Group I) had significantly poorer hearing than the other groups. The high frequencies (2-8 kHz) showed the greatest difference in terms of poorer fearing in both ears. The prevalence of noise-induced hearing loss (NIHL) was highest in Group I. A logistic regression analysis was applied to determine the dependence of the NIHL in relation to age, smoking, drinking, working duration, ear protection, past history of ear diseases, and working and military sonics backgrounds, on the noise exposure The important factors found to be related to the NIHL, in relation to noise exposure were: age, work duration, and working and military service backgrounds. The adjusted odds ratio estimates for NIML in the right ear were 4.5 times greater (95% CI 1.7-11.6) for the military noise exposed group, and 7.9 times greater (95% CI 2.0-31.3) for the working noise exposed group than in the controls. The hearing thresholds at the pure-tone average and 4 kHz were significantly increased with age and work duration with both the working and military service backgrounds. Conclusions : From these results, specific preventive programs were planned, which should be assessed by epidemiological surveillance of the military noise exposed population.

Dependences of Ultrasonic Parameters for Osteoporosis Diagnosis on Bone Mineral Density (골다공증 진단을 위한 초음파 변수의 골밀도에 대한 의존성)

  • Hwang, Kyo Seung;Kim, Yoon Mi;Park, Jong Chan;Choi, Min Joo;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.502-508
    • /
    • 2012
  • Quantitative ultrasound technologies for osteoporosis diagnosis measure ultrasonic parameters such as speed of sound(SOS) and normalized broadband ultrasound attenuation(nBUA) in the calcaneus (heel bone). In the present study, the dependences of SOS and nBUA on bone mineral density in the proximal femur with high risk of fracture were investigated by using 20 trabecular bone samples extracted from bovine femurs. SOS and nBUA in the femoral trabecular bone samples were measured by using a transverse transmission method with one matched pair of ultrasonic transducers with a center frequency of 1.0 MHz. SOS and nBUA measured in the 20 trabecular bone samples exhibited high Pearson's correlation coefficients (r) of r = 0.83 and 0.72 with apparent bone density, respectively. The multiple regression analysis with SOS and nBUA as independent variables and apparent bone density as a dependent variable showed that the correlation coefficient r = 0.85 of the multiple linear regression model was higher than those of the simple linear regression model with either parameter SOS or nBUA as an independent variable. These high linear correlations between the ultrasonic parameters and the bone density suggest that the ultrasonic parameters measured in the femur can be useful for predicting the femoral bone mineral density.

Designing and Realizing the Ground Station Receiver Low Noise Amplifier of the Next-Generation Aeronautical Surveillance System (차세대 항공 감시시스템(ADS-BES) 지상국 수신기 저잡음 증폭기 설계 및 구현)

  • Cho, Ju-Yong;Yoon, Jun-Chul;Park, Chan-Sub;Park, Hyo-Dal;Kang, Suk-Youb
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2273-2280
    • /
    • 2013
  • This article introduces the next-generation air surveillance system and investigates how to design of front-end low noise amplifier of the ground station receiver. In consideration of the international standard documentation and the performance of existing products, the study conducts the link budget on the entire system so that it can be competitive in terms of receive sensitivity or reliability. To obtain a proper low noise amplifier, standards of design are decided so that such factors as gain, gain flatness, and reflective loss can be optimal. In its design, the bias circuit appropriate for the characteristics of low power, low noise, or high gain was built, and according to the results of the simulation conducted after the optimal design, its gain was 16.24dB, noise factor was 0.36dB, input-output reflective loss was -18dB and -28dB each, and frequency stability was 1.11. According to the results measured after the design, its gain was 17dB, noise factor was 0.51dB, gain flatness was 0.23dB, and input-output reflective loss was -18.28dB and -24.50dB each, so the results gained were suitable for building the overall system.