• 제목/요약/키워드: 주파수조절

검색결과 717건 처리시간 0.027초

Vision and Aging

  • Kim, In Suk;Hilz, Rudolf
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제7권1호
    • /
    • pp.9-13
    • /
    • 2002
  • It is well known that the maximum amplitude of accommodation decreases with increasing age.(Presbyopia). With single vision lenses presbyopia can be corrected only for one viewing distance. With progressive power lenses presbyopia can be corrected for all viewing distances. But there are some other changes in the visual system with age which can not be corrected by spectacle lenses. Pupillary diameter decreases and the light transmission of the ocular media decreases. Therefore old people need more light, they need better illumination. Cone density in the retina decreases, this is only one example for changes in the sensory system. These changes in the visual system cause changes in visual functions. At the age of 80 visual acuity has decreased to half. Contrast sensitivity for gratings decreases mainly for high spatial frequencies very important is the increase of stray light in the ocular media and therefore the increase of glare. Veiling luminance increases by a multiple of approximately 4, Dark adaptation gets slower and light sensitivity is approximately 2 log units (factor 100) less when the eye is completely dark adapted. Also colour vision gets worse, especially at low luminances. Elderly people have problems with visual tasks which require divided attention between foveal and peripheral vision. An example is the measurement of the useful field of view. This useful field of view be expanded (improved) by visual training.

  • PDF

Surface treatment of polysaccharide by flexible active species generator (플렉서블 활성종 발생기를 이용한 다당류 표면처리)

  • Lee, Yu-Ri;Lee, Seung-Hun;Kim, Do-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.39-39
    • /
    • 2018
  • 최근 플라즈마 의학이 발달하면서 제트, 펜, 니들, 토치 등의 다양한 형태의 플라즈마 발생기가 개발되었으며 내부의 가스라인으로 가스의 종류, 유속, 조성 등을 조절하여 생물학적 효과를 극대화 할 수 있고 안정적으로 플라즈마 방전상태를 유지할 수 있으나 처리 면적이 좁아 실제 생물학적 시스템 (세포, 조직, 그리고 박테리아) 적용에 있어 한계점이 존재한다. 이러한 한계점을 극복하기 위해서 유전체격벽방전 (Dielectric barrier discharge, DBD) 방식을 이용한 플렉서블 활성종 발생기를 제작하고 생물학적 시스템에 적용하기 위한 방전 특성 평가를 진행하였으며, 간단한 in vitro 모델인 한천 젤을 이용하여 플라즈마 처리에 따른 전달물질의 침투거리를 확인하였다. 플라즈마 방전 시 생성되는 수산화기 [OH], 과산화수소 [$H_2O_2$], 초산소음이온 [$O_2{^-}$], 오존 [$O_3$], 그리고 산화질소 [$NO_x$]와 같은 산소 및 질소 활성종 (Reactive oxygen and nitrogen species, RONS)은 세포벽 또는 세포막의 주요 구성성분인 다당류와 인지질의 과산화 반응을 통해 구조를 변화시키고 생물학적 시스템의 표면의 pH를 낮춘다. 이러한 RONS의 작용은 살균, 소독 뿐만 아니라 약물의 침투를 돕는다. 일반적으로 한천 겔은 농도에 따라 생체 내 뇌 조직과 물리적 특성이 유사하고, 미생물학 기질, 방사선학 연구를 위한 조직모델로 사용되기 때문에 본 연구에서는 3%와 5% 농도의 한천 젤을 사용하여 침투거리를 확인하였다. 한천 젤은 $2.5{\times}2.5{\times}2.5cm^3$의 크기로 준비되었고 대조군으로 염료가 포함된 에멀젼을 0.01 g 도포하고, 실온에서 30분간 보존 후 단면을 잘라 현미경으로 침투거리를 확인하였으며, 실험군으로 플라즈마 전처리 후 에멀젼을 도포한 시표와 에멀젼 도포 후 플라즈마 처리한 시료에 대해 에멀젼 침투거리의 변화를 확인하였다. 본 연구의 플렉서블 활성종 발생기는 인체에 부착하여 사용되기 때문에 화상, 홍반을 유발을 방지하기위해 $40^{\circ}C$의 온도에서 실험을 진행하였고 이때에 플라즈마 방전조건은 $0.065W/cm^2$ 수준의 전력을 소모하는 1.7 kV의 전압, 16 kHz의 주파수로 10분간 처리하였다. 그 결과 3%의 한천 젤의 경우 침투거리 0.779 mm에서 0.826 mm, 0.942 mm까지 침투거리가 증가하였고 5%의 한천 젤의 경우 0.859 mm, 0.949 mm로 증가하였다. 이러한 침투거리 증가는 젤 표면의 다당류를 구성하고 있는 단량체가 플라즈마 처리시 화확적 구조가 끊어져 결론적으로 약물 침투가 증가된 것으로 판단된다.

  • PDF

Development of Closed-loop Control Type FES System for Restoration of Gait in Patients with Foot Drop (족하수 환자의 보행보조를 위한 피드백 제어형 전기자극기 개발)

  • 정호춘;임승관;이상세;진달복;박병림
    • Journal of Biomedical Engineering Research
    • /
    • 제20권2호
    • /
    • pp.183-190
    • /
    • 1999
  • The purpose of this study was to develop a portable and convenient closed-loop contrel type electrical stimulator for patients with foot drop. This system restores walking movement as well as prevents from atrophy or necrosis of lower limb muscles and increases blood circulation in hemiplegic patients caused by traffic accident, industrial disaster or stoke. This system detects the changes of the ankle joint angle during walking, and then controls the stimulus intensity automatically to maintain the programmed level of the ankle joint angle. Also, this automatic system controls the stimulus intensity which is affected by increased electrode impedance resulting from long time use. The system detects the joint angle by an optical sensor and includes modified PID control which adjusts the stimulus intensity if the joint angle deviates from the preset value. Stimulus parameters are 30~80 volt, 40 Hz, and 0.2 ms. The system was applied to five hemiplegic patients for 42 days. Duration of stimulation was 15 min/day for the first week and then the duration was gradually increased to 30, 60, 90 and 120 min/day. The muscle force was increased up to 29.7%, muscle fatigue was decreased compared with the level before stimulation and the pattern of locomotion was improved. These results suggest that the electrical stimulator with closed-loop control type is more convenient and effective in restoration of locomotion of patients with foot drop than open-loop system.

  • PDF

Implementation of Low Frequency Welding Pre-heating System Using Induction Heating (유도가열 기법을 이용한 저주파 용접예열 시스템 구현)

  • Yang, Juyeong;Kim, Soochan;Park, Junmo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • 제19권2호
    • /
    • pp.61-67
    • /
    • 2018
  • Welding preheating means that the surface of the base material to which the metal is welded before the main welding is heated to a constant temperature. It prevents the cracks of the adjacent influences such as reduction of material hardening degree by controlling the cooling rate, suppression of segregation of impurities, prevention of thermal deformation, and moisture removal. For this reason, it is a necessary operation for high quality welding. Induction heating is an efficient heating method that converts electric energy into heat energy by applying electromagnetic induction phenomenon. Compared with combustion heat generated by gas and liquid, it is clean, stable, and economical as well as rapid heating. It can be heated regardless of the shape, depth and material of the heating body by modifying the shape of the frequency and the coil with a simple structure. In this paper, we implemented a low frequency welding preheating system using induction heating technique and observed the temperature changes of coil resistance, inductance and automotive transmission parts according to the height of each transmission in winding coil for three kinds of automotive transmission parts. We confirmed that the change of current is a very important factor in the low frequency heating.

A comparative study of the acoustic characteristics of the vowel /a/ between children with spastic and dyskinetic cerebral palsy (경직형과 불수의운동형 뇌성마비아동의 /아/ 모음 음향학적 비교)

  • Jeong, Pil Yeon;Sim, Hyun Sub
    • Phonetics and Speech Sciences
    • /
    • 제12권1호
    • /
    • pp.65-74
    • /
    • 2020
  • This study aims to compare the acoustic characteristics of vowel phonation in children with spastic and dyskinetic cerebral palsy (CP). Thirty-four children aged 4-12 years with CP participated in the study (spastic 26, dyskinetic 8). Voice samples for the acoustic analysis were extracted from a sustained vowel /a/. All acoustic measures were made using Praat. Group differences were compared by an independent t-test or Welch-Aspin test, if the equivalence assumption was not met. The results of this study are as follow. First, maximum phonation time(MPT) was significantly shorter for the dyskinetic CP than for the spastic CP. Second, shimmer percent was significantly increased in the dyskinetic CP than in the spastic CP. Lastly, there were no significant group differences in both the first formant and the second formant. These findings indicate that the dyskinetic CP has a poorer respiratory capacity and poorer laryngeal function than the spastic CP. On the other hand, both groups have a comparable ability to articulate the vowel /a/. The results of the present study help speech language pathologists identify the speech motor control ability of children with two types of CP (spastic and dyskinetic) and help to make an intervention plan associated with a specific type of CP.

A Design of Novel Instrumentation Amplifier Using a Fully-Differential Linear OTA (완전-차동 선형 OTA를 사용한 새로운 계측 증폭기 설계)

  • Cha, Hyeong-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제53권1호
    • /
    • pp.59-67
    • /
    • 2016
  • A novel instrumentation amplifier (IA) using fully-differential linear operational transconductance amplifier (FLOTA) for electronic measurement systems with low cost, wideband, and gain control with wide range is designed. The IA consists of a FLOTA, two resistor, and an operational amplifier(op-amp). The principal of the operating is that the difference of two input voltages applied into FLOTA converts into two same difference currents, and then these current drive resistor of (+) terminal and feedback resistor of op-amp to obtain output voltage. To verify operating principal of the IA, we designed the FLOTA and realized the IA used commercial op-amp LF356. Simulation results show that the FLOTA has linearity error of 0.1% and offset current of 2.1uA at input dynamic range ${\pm}3.0V$. The IA had wide gain range from -20dB to 60dB by variation of only one resistor and -3dB frequency for the 60dB was 10MHz. The proposed IA also has merits without matching of external resistor and controllable offset voltage using the other resistor. The power dissipation of the IA is 105mW at supply voltage of ${\pm}5V$.

The RF Power Amplifier Using Active Biasing Circuit for Suppression Drain Current under Variation Temperature (RF전력 증폭기의 온도 변화에 따른 Drain 전류변동 억제를 위한 능동 바이어스 회로의 구현 및 특성 측정)

  • Cho, Hee-Jea;Jeon, Joong-Sung;Sim, Jun-Hwan;Kang, In-Ho;Ye, Byeong-Duck;Hong, Tchang-Hee
    • Journal of Navigation and Port Research
    • /
    • 제27권1호
    • /
    • pp.81-86
    • /
    • 2003
  • In the paper, the power amplifier using active biasing for LDMOS MRF-21060 is designed and fabricated. Driving amplifier using AH1 and parallel power amplifier AH11 is made to drive the LDMOS MRF 21060 power amplifier. The variation of current consumption in the fabricated 5 Watt power amplifier has an excellent characteristics of less than 0.1A, whereas passive biasing circuit dissipate more than 0.5A. The implemented power amplifier has the gain over 12 dB, the gain flatness of less than $\pm$0.09dB and input and output return loss of less than -19dB over the frequency range 2.11~2.17GHz. The DC operation point of this power amplifier at temperature variation from $0^{\circ}C$ to $60^{\circ}C$ is fixed by active circuit.

The Analysis and Implementation of Realistic Sound using Doppler Effect (도플러 효과를 이용한 실감 음향 분석 및 구현)

  • Yim, Yong-Min;Lim, Heung-Jun;Heo, Jun-Seok;Park, Jun-Young;Do, Yun-Hyung;Lee, Kangwhan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.523-526
    • /
    • 2017
  • In modern recently technology, 3D-Audio is used to enhance immersion in Virtual Reality. This includes interest of people about VR and AR, which related to the field of computer graphics. In fact, a lot of research has been carried out in recent years into a 3D sound field. However, the existing 3D generator device used for virtual reality does not contain Doppler effect occurred by the sound comes to or leave from a listener, while an angle from the listener and the altitude of the source sound are applied. Therefore, this paper present 3D real sound utilizing Doppler effect with spatial-rotation-speaker. We map the source sound in 3D-space into a real space where a user stays and present 3D real sound by manipulating with rotation angle, phase difference, sound output volume of the sound in 3D-space, according to the location of a virtual source sound. Utilizing both natural Doppler effect of rotating sound that is occurring by spatial-rotation-speaker and artificial Doppler effect generated by frequency-modulation of sound quality could improving the virtual reality for sound condition for perspective listening.

  • PDF

A Comparative Study of Aggregation Schemes for Concurrent Transmission over Multiple WLAN Interfaces (다중 무선랜 인터페이스 전송을 위한 결합 방식의 성능 연구)

  • Saputra, Yuris Mulya;Hwang, Hwanwoong;Yun, Ji-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제51권7호
    • /
    • pp.18-25
    • /
    • 2014
  • To increase wireless capacity, the concurrent use of multiple wireless interfaces on different frequency bands, called aggregation, can be considered. In this paper, we focus on aggregation of multiple Wi-Fi interfaces with packet-level traffic spreading between the interfaces. Two aggregation schemes, link bonding and multipath TCP (MPTCP), are tested and compared in a dualband Wi-Fi radio system with their Linux implementation. Various test conditions such as traffic types, network delay, locations, interface failures and configuration parameters are considered. Experimental results show that aggregation increases throughput performance significantly over the use of a single interface. Link bonding achieves lower throughput than MPTCP due to duplicate TCP acknowledgements (ACKs) resulting from packet reordering and filtering such duplicate ACKs out is considered as a possible solution. However, link bonding is fast responsive to links' status changes such as a link failure. It is shown that different combinations of interface weights for packet spread in link bonding result in different throughput performance, envisioning a spatio-temporal adaptation of the weights. We also develop a mathematical model of power consumption and compare the power efficiency of the schemes applying different power consumption profiles.

Acoustic Characteristics of Sound Field in Partially Opened Rooms -Emphasis on Vertical Coupling of Diffuse and Free Field- (실내공간의 부분적 개방에 따른 음향특성변화 II -확산음장과 자유음장의 수직적 결합을 중심으로-)

  • Jeong, Dae-Up;Choi, Young-Ji
    • Journal of Korean Association for Spatial Structures
    • /
    • 제7권5호
    • /
    • pp.75-82
    • /
    • 2007
  • The present work measured and analyzed changes in the acoustics of a sound field which has a retractable ceiling. An 1/20 scale model of an openable space was built and measurement was carried out by varying the opened area of a ceiling. The most widely used room acoustic and design parameters, RT, EDT, and D50 were investigated. The results suggest that the use of RT as an acoustic design parameter may not be proper in an openable space and further it is likely to mislead the initial acoustic design of such spaces. It is mainly due to the characteristics of RT in which non-exponential decay processes are linearly fitted. Early decay times were found to be decreased in proportion to increaing the ratio of opened area. D50, an index of speech intelligibility, was effectively shows the influence of openings on the acoustics. It is also found that EDT and D50 at the seats, not directly exposed to the opened part of a ceiling, were almost linearly decreased in proportion to the ratio of opened area, while little influence was found for the opening ratio larger than 40% at the directly exposed seats to the opened part of a ceiling.

  • PDF