• Title/Summary/Keyword: 주차 환기

Search Result 18, Processing Time 0.022 seconds

A Experimental Study on Ventilation Induced by Wind of Underground Parking Lots of Apartment Buildings (아파트 지하주차공간의 풍력환기에 관한 실험적 연구( I ) - 농도분포 및 환기회수에 관하여 -)

  • 김영덕;노지웅;정우성;오홍석
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.188-190
    • /
    • 1999
  • 현재 지하주차공간의 자연환기방식에 대한 우리나라 건축법규의 기준은 150m$^2$ 이내마다 1개소이상의 외기와 면하는 2m$^2$이상의 개구부를 천창 혹은 Dry Area를 설치하도록 규정하고 있다. 이 지하공간에서의 자연환기는 풍력, 온도차, 차량출입구에 의한 환기를 들 수 있으나 주로 풍력에 의한 환기가 대부분을 차지한다.(중략)

  • PDF

Numerical Simulation on Ventilation Characteristics of an Underground Bus Parking Lot (버스전용 지하주차장의 환기 특성에 관한 수치해석적 연구)

  • Seung, Sam-Sun;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.179-184
    • /
    • 2007
  • In this paper, the ventilation characteristics of an underground parking lot with 17 buses has been investigated for two cases by computational fluid dynamics. It has been found that the average concentration of CO and $NO_x$ gas in the parking lot were 1.3 and 0.3 ppm respectively, when four buses operated. When the fifteen vehicles stopped in the parking lot, the average concentration of CO and $NO_x$ gas was 2.9 and 0.8 ppm respectively. The average concentration of two pollutants$(CO,\;NO_x)$ are lower than the standard values. Therefore the facilities and its location is proper to ventilation.

  • PDF

Experimental Study on Wind-driven Ventilation in Basement Parking Lots of Apartment (풍동실험을 통한 공동주택 지하주차장의 자연환기 성능 연구)

  • Lee, Si-Woong;Roh, Ji-Woong
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.103-107
    • /
    • 2004
  • This paper aims for evaluating the wind-driven ventilation in basement parking lots of apartment. Wind tunnel tests coupled with tracer gas method were conducted, and classified by wind directions and opening types. The test results showed that, as for wind-driven ventilations, stack type openings were more successful than scuttle vent. Finally, according to Weibull distribution in Seoul, yearly averaged wind-driven ventilation rate was calculated.

A Study on Ventilation Performance driven by Wind Force in Underground Parking Lots of Apartment - Influence of Opening Size and Surrounding Building - (공동주택 지하주차장의 풍력환기 성능에 관한 연구 - 환기구 면적 및 주변건물의 영향 -)

  • Roh, Ji Woong
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.29-34
    • /
    • 2012
  • As a series of studies about natural ventilation driven by wind in basement parking lots of apartment, the influence of opening size and surrounding buildings on ventilation rate was analyzed. Natural ventilation in underground parking lots almost rely on wind than temperature difference. To investigate natural ventilation driven by wind, wind tunnel tests by using scale model and tracer gas method were conducted. $CO_2$-gas concentration was measured, natural ventilation rates were calculated. The experimental results showed that the natural ventilation rate is more reliable to wind direction and surrounding building than opening size and distance between buildings. It was verified that surrounding buildings play a principal role in increasing air flow rate by accelerating wind speed, and growing turbulence intensity. And it showed that ventilation performance is able to be increased by oblique wind to entrance ramp than head on wind in underground parking lots with surrounding buildings.

An Experimental Study on the Benefit of Pre-ventilation Using Solar Sunroof (쏠라 썬루프를 이용한 주차환기 시스템의 효과에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.6
    • /
    • pp.89-95
    • /
    • 2014
  • This study presented the benefit of the pre-ventilation using solar sunroof with integrated photovoltaic. Recent year, auto-makers make an effort to enhance the fuel efficiency and moreover to clean the cabin passenger's health. Solar energy, one of the alternative energies, adapted in automotive air handling system, in order to pre-ventilation when vehicle parked under the sun in summer. The power generated by a prototype solar sunroof has been used to run blower in a air handing system. And the solar sunroof was installed in a vehicle, and evaluated to find out benefit of the pre-ventilation. The effect of reducing the cabin temperature about $3^{\circ}C{\sim}10^{\circ}C$ with 20 ~ 40W power generator from solar sunroof were obtained in the pre-ventilation test. This reduced thermal load can lead to the reduction of air-conditioning operation time than that of current car. Moreover, fuel economy may increase as a results of the short use of the air-conditioning time. Additionally, Total Volatile Organic Compounds in the cabin is reduced maximum 80% than that of the current vehicle.

Economic Analysis for Warehouse Rental Using Underground Parking Lots Extra Storage Room of Rental Office (임대오피스 지하주차장 여유공간을 활용한 임대창고의 경제성 분석)

  • Lee, Hwan-Cheol;Song, Byung-Doo;Hong, Tae-Hoon;Hyun, Chang-Taek;Moon, Hyun-Seok
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.877-882
    • /
    • 2008
  • The column gap of underground parking lots of office considering a business background and effective parking divisions is planned. A parking plan by column gap of fixed forms in atypical underground parking lots makes much extra storage rooms. Most of the edge of the parking lots are used for fan room. Part of the edge are located at parking ramps. Also warehouses are located in extra storage rooms. In this study compare study economical efficiency between life cycle costs and leases earnings. Consequently, It is proved that the warehouse rental is efficient because of lease earning guaranted years.

  • PDF

VENTILATION DESIGN OF UNDERGROUND PARKING AREA IN A NEW BUILDING USING CFD (CFD를 이용한 신축건물 내 지하주차장의 환기설계)

  • Kim, J.H.;Yang, S.Y.;Lee, G.T.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.59-63
    • /
    • 2007
  • With the recent increasing demand on the high-performance buildings, there has been a rapid growth in the application of the Computational Fluid Dynamics to the Building design. The conceptual ventilation design of the underground parking area currently under construction is validated using the CFD-ACE+. It has been found that the conceptual ventilation design quantitively satisfies the legal standards. However, the highly concentrated region of CO is predicted. The positions and blowing directions of ventilating lane are changed based on the previously predicted concentration distributions. The highly concentrated region of CO is slightly reduced, but not much change has been observed. Two more fang are installed and the positions and blowing directions of the fans are modified so that the highly concentrated region of CO is minimized.

  • PDF

A Study on Wind-Driven Ventilation Performance According to Opening Types in Basement Parking Lots of Apartment - Investigation of Wind Pressure Coefficient by Wind Tunnel Test - (공동주택 지하주차장의 개구유형에 따른 풍력환기 성능에 관한 연구 - 풍동실험에 의한 풍압계수 검토 -)

  • Roh, Ji-Woong
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.37-42
    • /
    • 2011
  • This Paper aims for analyzing the effect of opening types on wind-driven ventilation performance in basement parking lots of apartment. The scale model of basement parking lot was made, wind tunnel tests conducted. Wind pressure of three opening types was measured, wind pressure coefficient calculated. As the result, it showed that the air flow pattern of stack type opening was strongly changed by wind direction, but it was almost not at scuttle vent type. But, as for the difference of wind pressure coefficient, stack type opening was more than the other two types.

Study of Pre-ventilation Effects on the Cabin Thermal Load (주차환기 시스템이 차 실내 열부하에 미치는 영향에 관한 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.5
    • /
    • pp.84-90
    • /
    • 2014
  • The aim of this paper is to investigate the application of solar energy in reducing cabin thermal load. When a vehicle is parked under the sun in summer, the interior temperature can reach up to $70^{\circ}C$ depending on the solar intensity. Solar power, one of the green energies, is used in automobile air conditioning systems, in order to operate the blower. The power supply of a blower's voltage has been used in a solar sunroof experiment. At the climate wind tunnel, cabin temperature changes were conducted with various operating modes of an air handling system and the preventilation parking conditions of several vehicles, outdoors, was also examined. The test results of the solar sunroof, 39.3W power and 14.1% efficiency were obtained. The thermal load behavior was analysed with the air handling system operating mode differently according to the cabin temperature. By simply operating the blower, average cabin temperature decreased between $5^{\circ}C{\sim}10^{\circ}C$ in those vehicles parked outdoors in summer. This reveals that cabin thermal comfort can be improved without consuming the vehicle's extra energy, and that the performance of the air-conditioning system is better than those currently found in vehicles. Moreover, fuel economy will be increased as a result of the reduction in the use of the air-conditioning system, and many other human advantages will be gained. Such advantages include minimized VOCs and a healthy cabin environment.