• Title/Summary/Keyword: 주입효율

Search Result 1,107, Processing Time 0.141 seconds

Removal Velocities of Pollutants under Different Wastewater Injection Methods in Constructed Wetlands for Treating Livestock Wastewater (인공습지 축산폐수처리장에서 주입방법에 따른 오염물질의 제거속도 평가)

  • Kim, Seong-Heon;Seo, Dong-Cheol;Park, Jong-Hwan;Lee, Choong-Heon;Lee, Seong-Tea;Jeong, Tae-Uk;Kim, Hong-Chul;Ha, Yeong-Rae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.272-279
    • /
    • 2012
  • In order to effectively treat livestock wastewater in constructed wetlands by natural purification method, removal velocities of pollutants under different injection methods in constructed wetlands were investigated. The removal velocities of chemical oxygen demand (COD), suspended solid (SS), T-N and T-P by continuous injection method were slightly rapid than those by intermittent injection method in full-scale livestock wastewater treatment plant. The removal velocity (K; $day^{-1}$) of COD by continuous injection method was $0.38\;d^{-1}$ for $1^{st}$ bed, $0.13\;d^{-1}$ for $2^{nd}$ bed, $0.17\;d^{-1}$ for $3^{rd}$ bed, $0.05\;d^{-1}$ for $4^{th}$ bed and $0.17\;d^{-1}$ for $5^{th}$ bed. The removal velocities (K; $day^{-1}$) of COD in $1^{st}$, $2^{nd}$, $3^{rd}$, $4^{th}$ and $5^{th}$ beds by intermittent injection method were $0.210\;d^{-1}$, $0.086\;d^{-1}$, $0.222\;d^{-1}$, $0.053\;d^{-1}$ and $0.137\;d^{-1}$, respectively. The removal velocity (K; $day^{-1}$) of SS by continuous injection method was $0.750\;d^{-1}$ for $1^{st}$ bed, $0.108\;d^{-1}$ for $2^{nd}$ bed, $0.120\;d^{-1}$ for $3^{rd}$ bed, $0.086\;d^{-1}$ for $4^{th}$ bed and $0.292\;d^{-1}$ for $5^{th}$ bed. The removal velocities (K; $day^{-1}$) of SS in $1^{st}$, $2^{nd}$, $3^{rd}$, $4^{th}$ and $5^{th}$ beds by intermittent injection method were $0.485\;d^{-1}$, $0.056\;d^{-1}$, $0.174\;d^{-1}$, $0.081\;d^{-1}$ and $0.227\;d^{-1}$, respectively. The removal velocity (K; $day^{-1}$) of T-N by continuous injection method was $0.361\;d^{-1}$ for $1^{st}$ bed, $0.121\;d^{-1}$ for $2^{nd}$ bed, $109\;d^{-1}$ for $3^{rd}$ bed, $0.047\;d^{-1}$ for $4^{th}$ bed and $0.155\;d^{-1}$ for $5^{th}$ bed. The removal velocities (K; $day^{-1}$) of T-N in $1^{st}$, $2^{nd}$, $3^{rd}$, $4^{th}$ and $5^{th}$ beds by intermittent injection method were $0.235\;d^{-1}$, $0.071\;d^{-1}$, $0.171\;d^{-1}$, $0.058\;d^{-1}$ and $0.126\;d^{-1}$, respectively. The removal velocity (K; $day^{-1}$) of T-P by continuous injection method was $0.803\;d^{-1}$ for $1^{st}$ bed, $0.084\;d^{-1}$ for $2^{nd}$ bed, $0.076\;d^{-1}$ for $3^{rd}$ bed, $0.118\;d^{-1}$ for $4^{th}$ bed and $0.301\;d^{-1}$ for $5^{th}$ bed. The removal velocities (K; $day^{-1}$) of T-P in $1^{st}$, $2^{nd}$, $3^{rd}$, $4^{th}$ and $5^{th}$ beds by intermittent injection method were $0.572\;d^{-1}$, $0.049\;d^{-1}$, $0.090\;d^{-1}$, $0.112\;d^{-1}$ and $0.222\;d^{-1}$, respectively.

Horizontal Flow Zeolite-Filled Reed Bed for Treatment of Artificial Sewage with Intermittent Feeding (수평 흐름 제올라이트 갈대 여과상에 의한 인공하수 처리)

  • 서정윤;최민수
    • KSBB Journal
    • /
    • v.18 no.6
    • /
    • pp.506-510
    • /
    • 2003
  • The artificial sewage was treated using a horizontal flow zeolite-filled reed bed. The artificial sewage was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of 314 L/㎡$.$day. The filtering height of the reed bed was 100 cm and the zeolite mixture was filled in the reed bed. The mixttjre consisted of the same volume of two types of zeolite: 0.5∼l mm and 1∼3 mm in diameter. Annual average removal efficiency was CODcr 95.8%, T-N 56.5%, NH$\_$4/$\^$+/-N 99.4% and T-P 61.3%. T-N removal efficiency decreased remarkably from 84 to 32% with the operating time.

Enhancement of Feed Gas Distribution of Heterogeneous Catalytic Fixed-bed Reactor

  • Lee, Ji Hyun;Kim, Beom-Ju;Kwak, No-Sang;Lee, Jung Hyun;Shin, Su Hyun;Hwang, Sun-Na;Shim, Jae-Goo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.595-600
    • /
    • 2016
  • 다상 고정층 촉매반응기(Multiphase catalytic fixed-bed reactor)에서 기체 유동과 관련, 반응기 내부 구조 디자인에 따른 feed 가스의 분산성 변화를 분석하였다. 다상 촉매반응기의 경우 feed gas의 투입방법이 전체 공정의 반응효율을 크게 결정하는바 본 연구에서는 산업현장에서 활용도가 높은 환형 가스 주입부로 구성된 다상 고정층 촉매반응기를 대상으로 다양한 조건하에서 촉매 반응기 내부에서의 feed가스 분산성 변화를 분석하였다. 다상 촉매반응기의 feed gas 주입과 관련하여 다양한 방안이 제시되고 있는데 그 중 환형 가스 주입방식을 활용하는 방법은 타 기술대비 상대적으로 저렴한 투자비와 좁은 작업공간하에서 기체의 분산성을 향상 시킬수 있는 특징이 있어 실제 상업 공정에서의 활용성이 매우 높다. 본 논문에서는 특히 기-고 촉매 반응기 내부 반응기체의 분산성 향상을 위해 환형 가스 주입장치 내부에 설치된 가스 주입홀 구성방법에 따른 반응기 내부 유동을 분석하였다. 분석결과 주입홀의 위치가 가스 투입라인의 접선방향에 위치하는 것은 전체 분산성에 큰 영향을 주지 못하며 대부분 가스투입 입구와 맞은편 부분에 위치하는 경우 분산성이 향상되는 것으로 분석되었다. 결과적으로 환형 가스주입장치의 최적 설계는 feed 가스의 분산성에 큰 영향을 미치므로 초기단계에서 이러한 점을 고려한 설계 및 분석연구가 선행되어야 할 것으로 사료된다.

Modeling of 3D Monte Carlo Ion Implantation in the Ultra-Low Energy for the Fabrication of Giga-Bit Devices (기가 비트급 소자 제작을 위한 3차원 몬테카를로 극 저 에너지 이온 주입 모델링)

  • Ban, Yong-Chan;Kwon, Oh-Seob;Won, Tae-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.10
    • /
    • pp.1-10
    • /
    • 2000
  • A rigorous modeling of ultra-low energy implantation is becoming increasingly more important as devices shrink to deep submicron dimensions. In this paper, we have developed an efficient three-dimensional Monte Carlo ion implantation model based on a modified Binary Collision Approximation(BCA). To this purpose, the modified electronic stopping model and the multi-body collision model have been taken into account in this simulator. The dopant and damage profiles show very good agreement with SIMS(Secondary Ion Mass Spectroscopy) data and RBS(Rutherford Backscattering Spectroscopy) data, respectively. Moreover, the ion distribution replica method has been implemented into the model to get a computational efficiency in a 3D simulation, and we have calculated the 3D Monte Carlo simulation into the topographically complex structure.

  • PDF

A Study of Heavy Metal-Contaminated Soil Remediation with a EDTA and Boric acid Composite(II): Cd and Cr (EDTA와 붕산 혼합용출제를 이용한 중금속으로 오염된 토양의 처리에 관한 연구(II): 카드뮴 및 크롬)

  • Lee Jong-Yeol;Kim Yong-Soo;Kwon Young-Ho;Kong Sung-Ho;Park Shin-Young;Lee Chang-Hwan;Sung Hae-Ryun
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.8-14
    • /
    • 2004
  • To investigate the optimal operation factors in appling Soil Flushing Process, which use EDTA and boric acid composite as a flushing reagent, to the Cd(cadmium) and Cr(chromium) contaminated sites, Cd and Cr emediation rate was investigated at various experimental conditions; as EDTA concentration was increased from 0.001M to 0.1M, Cd remediation rate was increased from $73.2\%\;to\;98.5\%$; as boric acid concentration was increased from 0.001M to 0.1M, Cr remediation rate was increased from $59.2\%\;to\;99.0\%$. In the experiments using 0.005M of EDTA and 0.005M of boric acid composite as a flushing reagent at different pH regimes, Cd remediation rate was decreased from $92.4\%\;to;80.9\%$ as the pH was increased from 3 to 7. But Cr remediation rate was more effective ($70.4\%$) at pH 5 compared to the other pHs. Furthermore, at pH 5, Cd and Cr remediation rate was investigated at different molecular ratio of [EDTA]/[Boric aicd]; the optimized [EDTA]/[Boric acid] ratio was 0.01M/0.1M for Cd contaminated site and, as the concentration of boric acid was increased over 0.1M, Cr remediation rate was also increased. So the similar results were shown in the experiments using real contaminated soils which were sampled from a mining and a industrial area.

다층 구조의 4,7-diphenyl-1, 10-phenanthroline과 tris(8-hydroxyquinoloine) Aluminum 전자수송층을 이용한 유기발광소자의 효율 증진 메카니즘

  • Jang, Jae-Seung;Kim, Dae-Hun;Lee, Gwang-Seop;Kim, Tae-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.472-472
    • /
    • 2012
  • 유기발광소자는 빠른 응답속도, 높은 색재현성, 높은 명암비의 장점을 가지고 있어 차세대 디스플레이로 각광 받고 있으며, 이미 소형 디스플레이로 상용화되고 있다. 유기발광소자에서는 발광효율을 높이기 위해서 전하들의 균형이 매우 중요하다. 유기발광소자 내 정공의 이동도는 전자의 이동도보다 빠르기 때문에 정공의 이동도를 감소하거나, 전자의 이동도를 증가하여 전하들의 균형을 형성함으로 유기발광소자의 효율을 증진시키는 연구가 진행되고 있다. 본 연구는 유기발광소자의 전자 수송층을 다층구조로 적층하여 전자의 이동도를 증가하여 효율이 증진하는 메커니즘을 기본으로 하였다. 전자 수송층을 tris(8-hydroxyquinoloine)aluminum ($Alq_3$) 단일층, 4,7-diphenyl-1, 10-phenanthroline (BPhen)과 $Alq_3$의 혼합층및 BPhen과 $Alq_3$ 다층 구조로 제작한 유기발광소자의 전기적, 발광 특성을 비교 분석하였다. BPhen은 lowest unoccupied molecular orbital (LUMO) 준위가 $Alq_3$의 LUMO 준위와 유사하여 전자 주입이 효율적으로 일어나며, 또한 낮은 highest occupied molecular orbital (HOMO) 준위는 정공 저지층의 역할을 하여 발광층 내에서 전하의 균형을 효율적으로 맞춰준다. 유기발광소자는 N,N,'-bis-(1-naphthyl)-N,N'-diphenyl1-1'-biphenyl-4,4'-diamine (NPB)/ $Alq_3$/ 다양한 전자수송층 / lithium quinolate (Liq)/ aluminium (Al) 음극 전극으로 각각 증착하여 제작하였다. 전자수송층을 다층 구조로 사용한 유기발광소자는 발광효율이 혼합층과 단일층에 비해 높았으며, 최대 발광효율은 전류밀도가 273 mA/cm2일때 4.5 cd/A였다. 다층구조의 전자수송층에서 다층으로 증착된 BPhen이 효율적인 전자 주입 및 전공 저지하는 역할을 최적화 하여 발광층에 더 많은 엑시톤이 형성하여, 유기발광소자의 효율을 증진시켜 준다는 사실을 알 수 있었다.

  • PDF

Degradation Characteristics of Oxalic Acid and Citric Acid by UV/H2O2 Oxidation (Oxalic Acid와 Citric Acid UV/H2O2에 의한 분해특성 조사)

  • Ha, Dong-Yun;Cho, Soon-Haing;Choi, Young-Soo;Kyung, Gyu-Seok;Kim, Dong-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1307-1318
    • /
    • 2000
  • The purpose of this study is to investigate the degradation characteristics of oxalic acid and citric acid by $UV/H_2O_2$ oxidation. For this purpose, the effects of pH, $H_2O_2$ dosage and the concentration of each compounds on the degradation of oxalic acid and citric acid by $UV/H_2O_2$ were investigated. Oxalic acid was effectively degraded at the wavelength of 254 nm, while the degradation efficiency of citric acid was very low at the same wavelength. It was also found that both organic substances were not degraded by the injection of $H_2O_2$ only. The optimum pH of degradation of oxalic acid and citric acid was 4 and 4 to 6, respectively. In the case of $UV/H_2O_2$ oxidation, the degradation efficiency was increased by increasing $H_2O_2$ dosage. The degradation efficiency decreased when the dose of $H_2O_2$ exceeds 200 mg/L. From these results, it can be concluded that the optimum reaction conditions for the degradation of oxalic acid and citric acid by $UV/H_2O_2$ oxidation were pH 4 and 200mg/L of $H_2O_2$.

  • PDF

Effective Key Disseminating Method for Fuzzy Logic Based Dynamic Filtering in Wireless Sensor Network (동적 여과 기법 기반의 무선 센서네트워크에서 효율적인 키 분배를 위한 퍼지 로직 기반 결정 기법)

  • Kim, Jong-Hyun;Cho, Tae-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.147-150
    • /
    • 2009
  • 최근 새롭게 등장한 무선 센서 네트워크는 기존의 네트워크와는 다르게 통신 인프라가 없는 환경에서도 동작이 가능한 저전력 소출력의 무선 센서간의 네트워크를 형성하고 이들간의 정보 유통이 이루어진다. 무선 센서 네트워크는 열린 환경에서 배치되기 때문에 물리적 공격에 취약하다. 공격자는 손쉽게 노드들을 포획할 수 있으며 포획된 노드를 통해 허위 보고서를 네트워크에 주입할 수 있다. 허위 보고서 삽입 공격은 허위 경보를 유발할 뿐만 아니라 네트워크의 제한된 에너지를 고갈시킨다. 이러한 허위 보고서를 조기에 탐지 및 폐기하기 위하여 Yu와 Guan은 동적 여과 프로토골(dynamic on-route filtering scheme)를 제안하였다. 그러나 무선 센서 노드는 오직 제한된 진력자원으로 이루어져 있기 때문에 전력보존과 전력관리가 중요시 여겨진다. 본 논문에서는 동적 여과 프로토콜에서 허위 보고서 주입 공격에 대한 충분한 보안 강도 제공과 에너지 효율성을 위한 기법을 제안한다.

  • PDF

Retrovirus를 이용한 형질전환닭 생산 연구

  • Park, Cheol;Byeon, Seung-Jun;Kim, Seong-U;Park, Jin-Gi;Jang, Won-Gyeong;Yang, Bo-Seok;Kim, Tae-Yun;Son, Si-Hwan;Kim, Sang-Hun
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2005.11a
    • /
    • pp.70-71
    • /
    • 2005
  • 본 연구는 1세포기 닭 수정란에 retrovirus vector (RSV-GFP)를 도입하여 외래유전자의 핵 전이 효율을 높이고자 하였다. 실험은 polybrene과 retrovirus 혼합물을 1세포기 또는 배반엽 단계의 수정란 세포질에 미세주입하고 배양 3 또는 4일차에 GFP의 발현 양상들을관찰하였다. 실험의 결과는 배반엽 수정란에서 GFP발현을 관찰할 수 있었으나, 1세포기 수정란에서는 GFP의 발현을 관찰할 수 없었다. 연구결과는 형질전환닭 생산에 있어서 가장 효율적인 방법은 배반엽 단계에 retrovirus를 미세주입하는 방법임을 보여주고 있다.

  • PDF

The Removal Characteristics of Caesium Ion by Chemical/Ultrafiltration Combination Process (화학적처리/한외여과막 결합공정에 의한 세슘이온의 제거 특성)

  • 정경환;이근우;김길정;박헌휘
    • Journal of Energy Engineering
    • /
    • v.3 no.1
    • /
    • pp.70-76
    • /
    • 1994
  • 본 연구는 방사성 폐액의 처리를 목적으로 화학처리와 한외여과막(UF)의 결합공정에 의해서 세슘이온의 제거특성을 조사하였다. 이 공정은 대상핵종과 선택성이 크고 한외여과막에 의해서 분리가 가능한 거대분자를 주입하여 핵종을 결합시키고, 이를 한외여과막에 의해서 분리 제거하는 개념이다. 실험은 흡착제로서 K2Cu3(Fe(CN6)2)를 제조하여 주입하였고 회분식 UF stirred cell를 이용하였으며, 용액의 pH, 세슘이온의 농도 및 K2Cu3(Fe(CN6)2)의 농도에 따라 세슘이온의 제거효율을 측정하였다. 세슘의 제거효율은 pH 및 K2Cu3(Fe(CN6)2)의 몰비에 따라 결정되며, pH가 5∼6에서 높은 제거율을 나타내었고 Cs/K2Cu3(Fe(CN6)2)의 몰비가 1.5 이하에서 90% 이상 제거되었다. K2Cu3(Fe(CN6)2)에 대한 Cs의 결합특성은 Langmuir isotherm형태의 식으로 나타내어 평가하였으며, 이때 세슘이온의 최대 흡착용량은 1.72 mM/mM K2Cu3(Fe(CN6)2) 이었다.

  • PDF