• Title/Summary/Keyword: 주입율

Search Result 986, Processing Time 0.029 seconds

Fluoride Removal Using Ready-Mixed Concrete Sludge (레미콘 슬러지를 이용한 불소제거)

  • Kang, Min-Koo;Shin, Gwan-Woo;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.803-808
    • /
    • 2013
  • The purpose of this study was performed to investigate the optimum conditions of pH, concrete sludge, seed dosage, mixing intensity, operation time in treating fluoride-containing wastewater as $CaF_2$ using the ready-mixed concrete sludge. Considering fluoride removal, water content, that pH 6, concrete sludge dosage of 10 g/L, Seed dosage ($CaF_2$) of 2 g/L, mixing intensity of 100 rpm and operation time of 60 min were found to be optimum. Correspondingly, removal of fluoride and water content was about 85% and 64%, respectively. Increase in amount of seed dosage did not affect fluoride removal efficiency. but the result that the water content is decreased was shown up in occuring the solid-liquid separation well.

부상공정과 PAC-MF에 의한 수용액으로부터 색 제거

  • Kim, Seon-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.435-438
    • /
    • 2002
  • The permeate flux was lower when PAC was added compared to without PAC system. It can be concluded that PAC is cause of membrane fouling. The effect of flow volume was found not significant for the three samples. But it was shown high rejection rate due to adsorption of organic matter to PAC in the case of adding PAC.

  • PDF

A Study on the Removal of Nitrogen and Phosphorus by Addition of Coagulant in the Sulfur Denitrification Process Coupled to the Membrane Bioreactor (MBR과 황탈질 공정에서 응집제 주입에 따른 질소.인 제거에 관한 연구)

  • Lee, Young-Ho;Yoo, Soung-Jong;Oh, Dae-Min;Lee, Young-Sin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.949-956
    • /
    • 2010
  • A method for simultaneous removal of nitrogen and phosphate from sewage by elemental sulfur denitrification with membrane bioreactor was proposed, and capacity $10\;m^3$/day of pilot plant was operated for 350 days. This study was investigated to have the effect of denitrification rate and T-P removal with the addition of Alum in Sulfur denitrification Reactor (SDR). The addition of Alum and alkalinity ($NaHCO_3$) in the effluent of MBR was tried to remove simultaneous phosphate and nitrogen in SDR. Characteristics of total nitrogen (T-N) and total phosphate (T-P) removal was compared without and with the addition of Alum as a coagulant. T-N removal without and with the addition of Alum was 92.1% and 87.8%, respectively. And denitrification efficiency was 93.8% and 87.1%, respectively. T-P removal rate was increased to 75.6% in SDR by addition of Alum (2.6~4 mg/L as Al), but T-P removal rate was about 26.7% without the addition of Alum. Therefore, denitrification rate was 6.7% of reduction but T-P removal rate was increased by addition of Alum.

수정율 저하문제와 그 대책

  • 정길생
    • KOREAN POULTRY JOURNAL
    • /
    • v.6 no.3 s.53
    • /
    • pp.80-83
    • /
    • 1974
  • 수정율은 수탉이 노화하거나 내분비선에 이상이 있을 때, 정액을 너무 자주 채취할 때, 여름에걸쳐 가을까지, 수탉의 영양상태가 나쁠 때, 채취한 정액에 오줌이나 계분이 혼입되었을 때 정액주입이 부적당할 때, 희석액이 변질되었을 때, 떨어진다. 수정율을 높이기 위하여 필요한 사항은 무엇인가 알아보자.

  • PDF

A Study on the Determination of Dielectric Constant of Saturated Porous Media Using Frequency Domain Reflectometry System (Frequency Domain Reflectometry System을 이용한 포화 다공질매질의 유전율 측정을 위한 연구)

  • 김만일;정교철
    • The Journal of Engineering Geology
    • /
    • v.14 no.2
    • /
    • pp.179-187
    • /
    • 2004
  • This study conducted a laboratory work to determine the change of dielectric constant of saturated soil porous media, which is injecting EML to use Frequency Domain Reflectometry(FDR) system and length 7cm-length measurement sensor. It is purpose of study that estimate a movement path through pore of soil for an ethanol mixing liquid(EML) which have the same specific gravity of water at $20{\;}^{\circ}C$, and determine to a dielectric measuring range for the measurement sensor. As an outflow point of saturated soil column upper part recedes from an EML inject point in EML diffusion test, the diffusion extent of EML through pore of saturated soil was expanded. And results of ail EML flow experiment were measured the change of dielectric constant at all measurement sensors which are placed to constant interval at the same travel time for saturated soil column. Therefore, the displace process of water that exist in pore of saturated soil by EML injection is enough available and confirm together mobility through pores.

Treatment of Livestock Wastewater by Electrochemical Method (전기화확적 방법에 의한 축산폐수의 처리)

  • Heo, Jong-Soo;Chung, Tae-Uk;Lee, Hong-Jae;Baek, Song-Bum;Cho, Ju-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.332-338
    • /
    • 1999
  • To treat livestock wastewater effectively by electrochemical method using a stainless steel electrode or au aluminum electrode, the effects of voltage, distance of electrodes and PACS(Poly Aluminum Chloride Silicate) dosage on removals of pollutants in batch experiment for investigation the optimum treatment conditions of livestock wastewater were investigated. The results were summarized as follows ; On the effect of voltage, temperature and pH in electrochemical reactor were increased with increase in voltage but EC was a reverse in both electrodes. Removals of COD and T-N were increased with increase in voltage in both electrodes. SS removal was greater than 90% regardless of voltage without doing electrochemical reaction over 15min at 20V or 12min at 30V in both electrodes. T-P removal was over 90% regardless of voltage in both electrodes. On the effect of distance between two electrodes, removals of COD, T-N and T-P were increased with closeness in distance between two electrodes, and SS removal was greeter than 90% regardless of distance between two electrodes in both electrodes. On the effect of PACS dosage, removals of COD, T-N and T-P were increased with increased in PACS dosage up to 200㎎/l in both electrodes. SS removal was greater than 90% regardless of PACS dosage in both electrodes.

  • PDF

Optimum Design on the Mixed Ratio of Injection Gas with CO2/N2 in Enhanced Coalbed Methane Recovery (석탄층 메탄가스 회수증진공법에서 CO2/N2 주입가스의 혼합 비율 최적 설계)

  • Yoo, Hyun-Sang;Kim, Young-Min;Lee, Jeong-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.2
    • /
    • pp.1-9
    • /
    • 2017
  • Enhanced coalbed methane recovery (ECBM), as injecting $CO_2$ or $N_2$ into the coalbed methane (CBM) reservoir for increasing methane recovery, takes center stage in these days. ECBM makes a better recovery than the conventional production method, it called dewatering process. However the characteristics of injection gas affect to methane recovery, thus analysis on the mixed ratio of injection gas should be required. In this study, CBM reservoir model was built to estimate the methane recovery of ECBM method by different mixed ratio of injection gas. Additionally, to consider the characteristics of injection gas such as carbon captured storage, nitrogen re-injection, etc. economic analysis was performed. The results showed that ECBM cases produced methane almost twice as much as dewatering case and $CO_2$ 10% and $N_2$ 90% case resulted in the highest methane recovery among the mixed gas cases. On the other hand, the results of economic analysis showed that $CO_2$ 20% and $N_2$ 80% case made the highest total production profit. Therefore, both the recovery of methane and economical efficiency should be considered to apply ECBM process.

토양의 특성에 따른 토양증기추출법 (Soil Vapor Extraction)의 Trichloroethylene (TCE)과 Toluene 정화 효율 실험

  • 강현민;이민희;정상용
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.191-194
    • /
    • 2002
  • 토양증기추출(Soil Vapor Extraction)법을 이용하여 대표적 휘발성 NAPL (Non-aqueous phase liquid)인 TCE (trichloroethylene)와 toluene을 토양으로부터 제거하는 칼럼 실험을 실시하였다. 토양특성 및 증기추출 조건들이 정화효율에 미치는 영향을 규명하는데, 균질한 Ottawa sand와 실제 오염지역의 토양들을 직경 2.5cm, 길이 30cm인 유리 칼럼이 충진시켰으며, 빨갛게 염색된 TCE 또는 toluene 4 g이 주입되었다 공기 유량계를 설치하여 0.03L/min의 일정한 속도로 공기가 주입되도록 하고, 퍼지장치를 설치하여 주입 공기의 습윤도를 99% 이상으로 유지하였다. 가스크로마토그래피로 유출 가스 농도를 분석하였다. Ottawa sand로 충진된 칼럼실험에서는 매질의 입자크기, 함수율, 토양 내 오염물 체류시간 등을 변화시켜 실험을 반복하였다. TCE로 오염된 세립질 Ottawa sand 칼럼실험에서 유출 공기의 최대 농도는 조립질 Ottawa sand 칼럼의 유출 농도보다 약 20% 정도 감소하였고, 오염지역의 실제토양 칼럼실험에서는 최대유출농도가 조립질 Ottawa sand 칼럼의 농도보다 약 50% 감소하였으나, 20 liter공기 주입 후부터는 모두 비슷한 농도감소 현상을 나타내었으며, 초기 주입량의 90 % 이상이 제거되었다. 함수율증가에 따른 유출공기의 농도 감소는 거의 나타나지 않았으며, TCE 주입 후 7일 동안 방치하였다가 SVE를 실시한 칼럼 실험에서도 잔류하는 TCE의 양이 약간 증가하였지만 20 liter 공기 추출 후에는 초기 주입량의 90% 가, 40 liter공기 추출 후에는 98% 이상이 제거되었다. Toluene으로 오염된 칼럼 실험에서도 TCE와 비슷한 제거 경향을 나타냈으며 200 liter 공기 추출 후에는 오염물 초기 주입량의 98% 이상이 제거되었다. 본 실험 결과로부터 증기추출법을 이용한 TCE, toluene 정화 효율성이 규명되었으며, 휘발성 NAPL로 오염된 실제 토양을 복원하기 위한 SVE법의 적용가능성을 확인할 수 있었다.

  • PDF

Determination of Optimun Coagulant Dosage for Effective Water Treatment of Chinyang Lake -The Effect of Coagulant Dosing on Remoaval of Colloidal Pollutants- (진양호소수의 효과적인 정수처리를 위한 최적응집제 주입량 결정 -콜로이드성 오염물질 처리를 위한 응집제 주입효과-)

  • 이원규;조주식;이홍재;허종수
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.761-772
    • /
    • 1998
  • This study was performed to determine the optimum coagulant dosing amount for effective treatment of raw water. The removal rate of turbidity and the variations of water qualities according to various dosage of coagulants such as Alum, PAC and PACS were investigated. The optimum coagulant dosing amount to make the lowest turbidity of water were 35mg/ι t of Alum, 30mg/ι of PAC and 10mg/ι of PACS in case of 5 NTU of raw water turbidity, and 30mg/ι of Alum, 25mg/ι of PAC and 10mg/ι of PACS in case of 10 NTU of that, respectively. The removal rates of turbidity at 4 min. and 8 min. of settling time were 10 and 72% of Alum, 44 and 62% of PAC and 25 and 55% of PACS in case of 5 NTU, and 52 and 70% of Alum, 90 and 95% of PAC and 10 and 28% of PACS in case of 10 NTU, respectively. Judging from the settling capability of floc., the reaction time of floe. formation and removal efficiency of turbidity, PAC was evaluated as more effective coagulant than Alum and PACS. Also PAC was regarded as the most effective coagulant when the water supply was changed sharply and the fluctuation of the surface loading occured with wide and sharp in settling basin. pH and alkalinity of the water were decreased with increasing coagulants dosage. But pH and alkalinity were not decreased below 5.8 which is the standard for drinking water quality, and 10mg/ι which is the limit concentration of floc. breakage, respectively. Residual Al of the treated water was decreased with increasing coagulants dosage in case of 5 and 10NTU of raw water turbidity. $KMnO_4$ consumption of the water was decreased with increasing coagulants dosage. The reduction rate of $KMnO_4$ consumption at the optimum coagulants dosage were 39% of Alum. 18% of PAC and 11% of PACS in case of 5 NTU of raw water turbidity, and 42% of Alum, 27% of PAC and 36% of PACS in case of 10 NTU of that, respectively. Any relationship was not found between the removal rate of turbidity and KMnO$_4$ consumption. TOC of the water was a bit decreased with increasing coagulants dosage up to 30mg/ι but not changed above 30mg/ι of coagulants dosage. The degree of TOC reduction was increased in the order of Alum, PAC and PACS treatment. Zeta potential of the colloidal floe. at the optimum coagulants dosage was in the range of -20~-15mV in case of 5 NTU of raw water turbidity and 0~0.5mV in case of 10 NTU of that. respectively. Although the kinds and dosages of coagulants were different, zeta potential range were fixed under the conditions of the best coagulation efficiency.

  • PDF

Removal of Dissolved Organic Nitrogen from Surface Water and Reclaimed Water by Coagulation (지표수 및 재이용수내 용존 유기질소의 응집처리)

  • Lee, Wontae;Choi, June-Seok;Oh, Hyun Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.729-734
    • /
    • 2012
  • During chlorination processes dissolved organic nitrogen (DON) can form toxic nitrogenous disinfection byproducts and organic chloramines which have little or no bactericidal activity. DON needs to be removed before chlorination processes to reduce the formation of those products. This study investigated the removal of DON from surface water and reclaimed water by coagulation with aluminum sulfate (alum) and a cationic polymer (polyDADMAC). Removal characteristics of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$) were compared with that of DON. Coagulation with alum removed DON, DOC, and $UVA_{254}$ with similar trends, but the removal of $UVA_{254}$ was highest. A dual coagulation strategy of alum and cationic polymer improved the removal of DON. Coagulation with cationic polymer alone was not effective due to its narrow range of charge neutralization. DON in reclaimed water was easier to remove than that in surface water, and higher molecular weight fraction (>10,000 Da) of DON was preferentially removed.