Effect of Gamma Rays Emitted by the 99mTc on the CT Image (99mTc에서 방출되는 감마선이 CT 영상에 미치는 영향)

  • Park, Jae-Yoon;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.169-174
    • /
    • 2019
  • This study examines the changes that $^{99m}Tc$ causes to CT(Computed Tomography) images quantitatively when CT scans were continuously performed using $^{99m}Tc$. With the use of the CT, $^{99m}Tc$ 740MBq was injected into the Resolution Phantom and Water Phantom, and the tube voltage was changed with 80 kVp and 120 kVp, scanning before and after the injection. The result indicate, by comparing the Signal Intensity according to the presence or absence of the $^{99m}Tc$ injection with the tube voltage of 120 kVp and 80 kVp, a decrease of 0.173 and 0.241 was observed respectively and the spatial resolution increase of 0.090 and 0.109 was observed respectively. The order of the test should be considered because the gamma rays of the radiopharmaceutical used in the nuclear medicine test do not affect the CT while the effective half-life of the radiopharmaceuticals should be considered for the CT scan to reduce the influence of the gamma rays emitted after the nuclear medicine test, with the possibility to reduce the difference of the results.

Measurement of Channel Impedance Characteristics for Indoor Power Line Communications (옥내 전력선 통신 채널 임피던스 특성 측정)

  • Heo Yoon-Seok;Kim Chul;Hong Bong-Hwa;Lee Dae-Young;Jun Kye-Suk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.79-86
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency $30khz\~1Mhz$ band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

The Inhibitory Effects of Melittin on Human Prostate Cancer Cell PC-3 in vivo and in vitro (Melittin의 전립선암세포 증식에 대한 억제 효과)

  • Yun, Jong-Il;Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.24 no.2
    • /
    • pp.51-61
    • /
    • 2007
  • 목적 : 이 연구는 봉독의 주요 성분인 낮은 농도의 melittin이 in vitro에서 세포자멸사 관련 단백질과 전립 선암세포 PC-3 증식 관련 수용체의 발현 조절을 통하여 세포자멸사(Apoptosis)를 유도하는지 in vivo에서 또한 전립선 암세포주인 PC-3 세포의 성장을 억제하는지 살펴보고자 하였다. 방법 : Melittin을 처리한 후 전립선암세포 PC-3의 성장억제를 관찰하기 위해 WST-l assay와 morphology analysis를 시행하였고, 세포자멸사 관련 MAP kinase 계열의 대표인 ERK1/2과 전립선암세포 증식관련 수용체인 PDGF-BB receptor ${\beta}$의 활성 변화 관찰에는 western blot analysis 및 Immunofluorescence Staining , Confocal immunocytochemistry를 시행하였으며, 전립암세포의 종양형성에는 흉선을 제거한 쥐에 Tumorigenecity study를 시행하였다. 결과 : 1. PC-3 세포에서 Melittin 처리 후 세포증식이 억제되었고 세포의 형태는 세포자멸사의 특징을 나타내었다. 2. PC-3 세포에서 Melittin 처리 후 ERKl/2과 PDGF-BB receptor ${\beta}$의 활성이 억제되었다. 3. PC-3 세포에서 Melittin과 AG1296을 함께 투여시 PDGF-BB receptor ${\beta}$ 활성억제의 상승효과가 나타났다. 4. 흉선 제거 후 전립선암세포주를 이식한 쥐에서 Melittin을 피내로 주입한 결과 전립선암의 크기와 무게가 유의하게 감소하였다. 결론 : 이상의 결과는 Melittin이 ERKl/2과 PDGF BB receptor ${\beta}$의 활성 억제를 통하여 인간 전립선암세포주인 PC-3의 세포자멸사를 유발함으로써 증식억제 효과가 있음을 입증한 것이며, 이를 재확인한 생처 연구에서의 긍정적인 결과는 향후 Melittin의 전립선암 예방과 치료에 대한 효과적인 치료제 개발에 초석이 될 것으로 기대된다.

  • PDF

Effect of the Sprue Design on the Fitness of Implant Prosthesis (주입선의 설계가 임플란트 보철물의 적합도에 미치는 영향)

  • Hwang, Sung-Taek;Ahn, Jae-Seok;Shin, Sang-Wan
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.57-63
    • /
    • 2008
  • Statement of problem: Conventional techniques for implant framework fabrication produce significant error that is inconsistent with passive-fit requirement for osseointegrated implants. One of the etiologic factors which cause the errors is a sprue which may deform the framework during solidification and contraction. Purpose: This study was aimed to evaluate objectively effect of the sprue design on the accuracy of fit of implant prosthesis. Materials and method: Three different designs were considered relative to effect of casting accuracy. The first design had straight sprues and a button of excess alloy at the non-casting end of the sprues. The second was runner bar design(with the button). The last was straight sprues design(without the button). Gold cylinder and laboratory analogue had been used to diminish variables affecting to casting accuracy. Gold alloy and pressure-vacuum casting machine had been used. Marginal gap had been measured by SEM. One-way ANOVA and Duncan test had been used for statistical analysis. Results: The first design showed $79.87{\pm}13.95{\mu}m$ marginal gap. The second and third were $40.17{\pm}15.8{\mu}m$ and $35.17{\pm}9.95{\mu}m$ respectively. Conclusion: Straight sprues without button and runner bar designs were more accurate than straight sprues with button design(P<.05).

  • PDF

A Study of Semiconductor Process Simulator with User Friendly Framework (사용자 친숙형 반도체 공정 시뮬레이터의 구성에 관한 연구)

  • 이준하;이흥주
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.4
    • /
    • pp.331-335
    • /
    • 2004
  • In this paper, we modeling the oxidation, diffusion, and ion-implantation for semiconductor process simulation, and construct the integrated framework for efficient execution and continuous process simulation. For oxidation process, to predict the accurate LOCOS shape and stress distributions, stress-dependent viscous model was performed using SVP algorithm. For diffusion process, predeposition and OED simulation was performed using point defect theory. For ion implantation, Monte-Carlo method based on TRIM simulation was performed with various process conditions. For input to each unit process, we used the dialog boxes which are windows application's standards. This dialog box allows us to verify and minimize input error at input steps. Using the combination of compiler's function and windows's API function, simulation was done with small memory size.

  • PDF

Determination of DBCP and n-Butylbenzene using SPME with GC-MS (SPME-GC-MS를 이용한 DBCP 및 n-Butylbenzene의 분석)

  • Park, Hyun-Mee;Kim, Young-Man;Lee, Dai-Woon;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.471-475
    • /
    • 2001
  • Solid phase microextraction(SPME) with $85{\mu}m$-polyacrylate (PA) and $100{\mu}m$-polydimethylsiloxane(PDMS) fibers, coupled to gas chromatography-mass spectrometry was used to determine 1,2-dibromo-3-chloropropane(DBCP) and n-butylbenzene in water. The conditions affecting the SPME process(i.e, extraction time, injection length, injection temperature, desorption time and temperature) were optimized. The linearity of the calibration curve (correlation coefficient, R) was over 0.99 and the limits of detection of the method were between 1.5 and $10.8{\mu}g/L$. Repeatability of the method was between 10.4 and 14.4 %.

  • PDF

Thermal and Chemical Quenching Phenomena in a Microscale Combustor (I) -Fabrication of SiOx(≤2) Plates Using ion Implantation and Their Structural, Compositional Analysis- (마이크로 연소기에서 발생하는 열 소염과 화학 소염 현상 (I) -이온 주입법을 이용한 SiOx(≤2) 플레이트 제작과 구조 화학적 분석-)

  • Kim Kyu-Tae;Lee Dae-Hoon;Kwon Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.397-404
    • /
    • 2006
  • Effects of surface defect distribution on flame instability during flame-surface interaction are experimentally investigated. To examine chemical quenching phenomenon which is caused by radical adsorption and recombination processes on the surface, thermally grown silicon oxide plates with well-defined defect density were prepared. ion implantation technique was used to control the number of defects, i.e. oxygen vacancies. In an attempt to preferentially remove oxygen atoms from silicon dioxide surface, argon ions with low energy level from 3keV to 5keV were irradiated at the incident angle of $60^{\circ}$. Compositional and structural modification of $SiO_2$ induced by low-energy $Ar^+$ ion irradiation has been characterized by Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS). It has been found that as the ion energy is increased, the number of structural defect is also increased and non-stoichiometric condition of $SiO_x({\le}2)$ is enhanced.

Anti-inflammatory Effects of Korean red ginseng Extract in formalin-induced Orofacial Pain in Rats (포르말린으로 유도된 안면통증에 대한 홍삼추출물의 항염증 효과)

  • Jin, Byung-Moon;Lee, Min-Kyung;Lee, Jun-Seon;Hyun, Kyung-Yae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5708-5715
    • /
    • 2014
  • The effects of korean red ginseng (KRG) extracts on orifacial pain control in terms of the systemic inflammatory response and pharmacological effects as health supplements were investigated. The experimental group were divided into three groups, the control group (n=6), formalin (5%, $50{\mu}{\ell}$) injection group (n=6), and formalin (5%, $50{\mu}{\ell}$) injection added KRG administrated group (4.5 ml/kg, n=6). The KRG administrated group prior to the formalin injection significantly attenuated the behavioral response compared to that of the control group. Pain reduction was suppressed mainly from 15 min to 30 min. The KRG administrated rats showed significantly reduced p38 MAPK, iNOS and Nrf2 expression in the brain and medulla oblongata according to Western blot analysis. These findings suggest that KRE may have a useful effect on orificial pain control functions by preventing the p38 MAPK pathway.

Realtime Compensation of PCC Voltage Variation by Injection of Required Reactive Power in a Grid Connected Variable Speed Wind Turbine (계통 연계형 가변속 풍력발전기의 무효전력 주입을 통한 PCC 전압 변동량 실시간 보상)

  • Im, Ji-Hoon;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.69-74
    • /
    • 2010
  • In a grid connected variable speed wind turbine, the PCC voltage and the wind power fluctuate as the wind velocity changed. And this voltage variation is changed due to location of PCC. This paper calculate the value of PCC voltage variation which is proportional to the product of the line impedance from the ideal generator to the PCC and the wind turbine output current. And to reduce this PCC voltage variation, this paper calculate the required reactive power analytically using the vector diagram method. Output reactive current is changed, if the reactive current is limited by inverter capacity or grid code have the margin of voltage variation. If the grid connected inverter is controlled by proposed algorithm, the PCC voltage variation is minimized though the wind turbine output change at random. To verify calculated voltage variation and required reactive power, this paper utilized Matlab and PSCAD/EMTDC simulation and real small wind turbine and power system in Sapsido, island in the Yellow Sea.

Analytical Performance Evaluation of Pneumatic Nebulizers and Comparison of Their Characteristics (가압분무기의 성능 평가와 특성 비교)

  • Park, Chang Joon;Han, Myung Sub;Song, Sun Jin;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.120-126
    • /
    • 2002
  • The analytical performance of four commercially-available pneumatic nebulizers(Meinhard, Cross-flow, Babington, ESI PFA) was evaluated using inductively coupled plasma-atomic emission spectrometry (ICP-AES) and ICP-mass spectrometry (ICP-MS) instruments. The performance of an inert concentric nebulizer and a modified conespray nebulizer, made in Korea Research Institute of Standards and Science (KRISS), is compared with that of the four commercial nebulizers. Variation of sample introduction efficiency was investigated as carrier argon pressure and sample uptake rate were changed. Variation of sensitivity, signal stability, blank intensity and oxide/hydride ratios were also studied when the nebulizers were connected to the ICP-MS and ICP-AES instruments. It was found that good analytical result such as high sensitivity, low blank, stable signal and so on can be obtained with judicious selection of the nebulizer depending on the type of sample, sample amount, type of analytical instrument and analyte.