• Title/Summary/Keyword: 주시시차

Search Result 26, Processing Time 0.025 seconds

The Study of Vertical Fixation Disparity by Fixation Disparity Card (주시시차 카드를 이용한 수직주시시차 연구)

  • Park, Hyun-Ju;Yoon, Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: This study was performed to determine vertical fixation disparity by Fixation Disparity Card. The purpose of this study was to investigate distribution of the curve types obtained with Wesson card. Methods: Fixation disparity curves were measured on 52 subjects with the Wesson fixation disparity card. A fixation disparity curve was an x, y coordinate plot of the angular amount of fixation disparity as a function of the power of prisms through which the patient views. The fixation disparity curve variables that were used to aid in the diagnosis and management of binocular vision disorders included the x-intercept, y-intercept, curve slope and curve type. Results: Vertical fixation disparity curves by Wesson Fixation Disparity Card were very various. Conclusions: Vertiical fixation disparity curves could be used to aid in the diagnosis and prescription.

Analysis of Binocular Vision by Wesson Fixation Disparity Card (Wesson Fixation Disparity Card를 이용한 양안시 분석)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • A commonly used device to determine fixation disparity curves is the Wesson Fixation Disparity Card. A fixation disparity curve is an x, y coordinate plot of the angular amount of fixation disparity as a function of the power of prisms through which the patient views. The fixation disparity curve variables that are used to aid in the diagnosis and management of binocular vision disorders include the x-intercept, y-intercept, curve slope and curve type. Fixation disparity curves were measured on 102 subjects with the Wesson fixation disparity card. The purpose of this study is to investigate distribution of the curve types obtained with Wesson card. Fixation Disparity by Wesson Fixation Disparity Card were that in case of type I 63.0%, in case of type II 0.0%, in case of type III 25.0% and in case of type IV 12.0%.

  • PDF

Relationship of Fixation Disparity and Heterophoria According to Fixation Distance (원, 근거리에서 주시시차와 사위와의 관계)

  • Kim, Chang-Jin;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • Purpose: This study measured Y-intercept that means a fixation disparity, X-intercept that means a associated phoria and slope of a fixation disparity curve (FDC), which are variables of dissociated phoria and the FDC. We searched for the result value and examined the direction, distribution pattern and a variable that give an most affect on dissociated phoria and the FDC at distance and near. Also this study examined that there were statistically significant differences between distance and near, comparing the result value. Methods: We measured the dissociated phoria and the fixation disparity for 51 subjects at distance and near in June, 2007. All subjects ranged from 20 to 25 years of age (average 21.72${\pm}$1.88 years old) and had no eye disease. At distance the dissociated phoria measured with the distance MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the modified Mallett Far Unit (Bernell co., USA). At near the dissociated phoria measured with the near MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the Wesson fixation disparity card (American Optical co., USA). Results: The percentage distribution of types of fixation disparity curves was that at distance prevalence of Type I (74.6%) was the highest, followed by Type IV (17.6%) and Type II (3.9%), Type III (3.9%) and that at near prevalence of Type I (53.0%) was the highest, followed by Type III (29.4%), Type IV (13.7%) and Type II (3.9%). 2. There were significantly correlation in dissociated phoria, fixation disparity (Y-intercept) and associated phoria (X-intercept). 3. The fixation disparity at distance was most affected by associated phoria (X-intercept) (p=0.000). The distance dissociated phoria was most affected by fixation disparity (Y-intercept) (p=0.342), but the influence was weak. 4. The fixation disparity at near was most affected by associated phoria (X-intercept) (p=0.000). The near also dissociated phoria was most affected by associated phoria (X-intercept) (p=0.009). The result that compared the each variables with the same variables at distance and near had statistically significant on paired t-test for among dissociated phoria (t=7.529, p=0.000), X-intercept (t=5.860, p=0.000), the Y-intercept (t=4.640, p=0.000) but slope of the FDC did not differ significant (t=1.336 p=0.188). Conclusions: Relationship of fixation disparity and Heterophoria had close correlation at distance and near.

  • PDF

A Correlation Between Vertical Fixation Disparity and Stereopsis at Near (근거리에서 수직주시시차와 입체시와의 관계)

  • Yoon, Min-Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.321-327
    • /
    • 2013
  • Purpose: To investigate a correlation between vertical fixation disparity and stereopsis by analyzing distribution of types of vertical fixation disparity. Methods: In this study, RANDOT(R) stereotest partly using random dot was used in stereopsis tests. The vertical fixation disparity in close proximity categorized fixation disparity slope into six types on the basis of the result of measurement in when two thin lines, one for one eye looks, become overlapped as a line by adding into prism with Wesson fixation disparity card while maintaining a distance of 25 cm from patients. Results: In the types of near vertical fixation disparity curve, targeting 43 people, the first type 55.82% was the most distributed, the second type is the least 23.25%, the third type of 4.65%, the fourth type of 4.65%, the fifth type of 6.98%, the sixths types of 4.65% were distributed. The result of a correlation analysis, which shows the degree of linear correlation between two variables, represented that stereopsis is not correlated with Y-intercept (r = -0.07) which show vertical fixation disparity, associated phoria (r = -0.03) and dissociated phoria (r = -0.00), but it was not statistically significant (p>0.05). Fixation disparity slope of vertical fixation disparity (r = 0.36) was shown to have a positive correlation with stereopsis. It has a low positive correlation and a meaningful statistics (p<0.05). The Y-intercept which indicates vertical fixation disparity was also not associated with stereopsis (r = -0.07) and dissociated phoria (r = -0.03), and this was not statistically significant (p>0.05), while it had a high correlation as well as a statistically significant with associated phoria (r = 0.89). There was a negative correlation between Y-intercept and fixation disparity slope of vertical fixation disparity (r = -0.33). It showed a low relationship but statistically valuable (p>0.05). As a result of regression analysis, the stereopsis was changed as 7.631" if vertical fixation disparity changes 1' and the vertical fixation disparity changed as 0.017' if stereopsis changes 1', and the change was statistically significant (p<0.05). Conclusions: The study shows that there is a low correlation between stereopsis and vertical fixation disparity, and it is difficult to determine stereopsis only using vertical fixation disparity. Therefore, it suggests other factors above vertical fixation disparity have greater influence on stereopsis.

The Change After Visual Training of Forced Vergence Fixation Disparity Curve (강제vergence 주시시차곡선의 시기능훈련 후의 변화)

  • Choi, Sun-Mi;Lee, Ki-Young;Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.539-550
    • /
    • 2014
  • Purpose: This research was designed to figure out if there are changes based on types of vergence fixation disparity curve after optical correction and vision training to for people with steep slope of forced vergence fixation disparity curve and symptoms. Methods: For 30 subjects out of 91 subjects, who have steep slopes of fixation disparity curve examined with Wesson Fixation Disparity Card and symptoms about steep slope of fixation disparity curve, proper vision training was offered for 5 weeks. Results: After Vision training for 30 people with the symptoms of type I, II, III, IV for 5 weeks, slope of fixation disparity curve was significantly changed (p=0.013), and the results of binocular vision test and subjective symptoms were also significantly improved. Conclusions: Vision training can not only affect the change of fixation disparity curve, but also relieve the symptoms. Fixation disparity curve has lots of visual function information of the subject and can be suggested as a guideline for prescribing.

Vergence control of parallel stereoscopic camera using the binocular disparity information (시차정보를 이용한 수평이동방식 입체영상 카메라의 주시각제어)

  • Kwon, Ki-Chul;Kim, Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.2
    • /
    • pp.123-129
    • /
    • 2004
  • This paper concerns auto vergence control of a parallel stereoscopic camera through geometrical analysis. In the construction of a parallel stereoscopic camera, we experimentally demonstrated linear relationship between the key object distance and the amount of vergence control. And we proposed a vergence control system for the stereoscopic camera using binocular disparity information. For the real-time calculation of disparity information, the Hybrid Cepstral filter algorithm, with input data acquired from the vertical projection data and from the down sampling data from the source images, was proposed for precision and high speed processing. With the disparity information algorithm and the vergence control of the parallel stereoscopic camera system, the stereoscopic images become more like those of the human eye.

Change of Fixation Disparity and Accommodation when the Fusion Contrast Varied (융합대비에 따른 주시시차와 조절의 변화)

  • Seo, Jae-Myoung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: To study the change of fixation disparity and accommodation as fusion contrast is deteriorated. Methods: 16 subjects who had above 20/20 and stereopsis took part. Monocular and binocular refraction were done with Zeiss Polatest Classic whereas the critical angle for stereopsis was done with TNO. A computer programmed with Random-Dot stereogram and vernier test managed a precise change of the fusion contrast and exposure time. Results: The fixation disparity was influenced by reduction of fusion contrast and had tendancy to exophoria (p=0.0004), especially it is considerably higher when uncrossed disparity was shown to exophoric subjects. Although accommodation was not influenced by a change of fusion contrast (p=0.803), vernier acuity was influenced (p=0.0000). Conclusions: Exophoric trend arose as the fusion contrast was reduced, nevertheless there was no accommadative change.

  • PDF

Implementation of Real-time Vergence Control System for Stereoscopic Camera (스테레오 영상의 실시간 주시각 제어 장치 구현)

  • 백승호;김균수;김석민;김재한
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.475-477
    • /
    • 2002
  • 입체영상을 관측할 때 눈의 피로를 최소화할 수 있는 자연스러운 입체영상을 얻기 위해서는 양안식 카메라의 주시각을 제어하여야 한다. 움직이는 물체에 대한 양안식 카메라의 주시각 제어를 위해 획득 영상의 edge 정보를 이용한 주시각 제어에 대하여 연구하였다. 양안식 입체 카메라로 획득한 좌.우 영상에서 edge정보를 추출하고, 이를 이용하여 양안시차를 구하고 주시각 제어에 이용함으로써 영상의 변화와 관계없이 양안시차를 항상 일정하게 유지할 수 있도륵 하였다. 본 논문에서는 간단한 연산만을 사용함으로써 응답속도가 빠르고, 하드웨어 구성도 매우 간단해 지도록 하였다. 또한 영상의 특성에 맞는 알고리즘을 사용할 수 있도록 2 mode 동작 시스템으로 구성하여 오차를 최대한 줄이며 움직이는 물체에 대한 연속적인 주시각 제어를 할 수 있도록 구현하였다.

  • PDF

Study on Automatic Vergence Control of Horizontal-Moving Axis Stereo Camera (수평식 입체영상 카메라의 자동 주시각 제어 연구)

  • 이용범;권기철;윤종건;최영수
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.1067-1070
    • /
    • 1999
  • 본 논문에서는 수평식 입체영상카메라의 주시각 자동제어를 위한 고속, 고정밀 시차추출 알고리즘을 제안한다. 제안된 알고리듬은 수평식 입체영상 카메라의 초점과 주시각의 선형적 관계에 따라 사람의 눈에서와 같은 자연스럽고도 선명한 입체영상을 획득할 수 있도록 주시각 및 초점제어를 동시에 자동 제어하며, 입체영상에 포함되어 있는 평면 및 상하 불일치 영역을 최소화하기 위한 전처리 과정과 고속, 고정밀 시차추출을 위한 프로젝션 및 켑스트럼(Cepstrum) 필터링 과정이 포함되어 있다. 제안된 알고리듬은 수평식 입체카메라의 실시간 제어를 가능하게 하며 카메라 조작자의 초점 및 주시각 제어에 대한 부담을 줄여 준다.

  • PDF

Hybrid Cepstral Filter for Precise Vergence Control of Parallel Stereoscopic Camera (수평이동방식 입체카메라의 주시각 제어를 위한 Hybrid Cepstral Filter에 의한 시차정보 추출)

  • Kwon, Ki-Chul;Kim, Nam
    • Journal of Broadcast Engineering
    • /
    • v.9 no.1
    • /
    • pp.91-94
    • /
    • 2004
  • The vergence controls of the parallel stereoscopic camera need only the disparity information of left and right images in horizontal direction. This paper proposed past and precise disparity value for stereoscopicimage pair in horizontal direction and the algorithm which can abstract disparity information through the HCF(Hybrid Cepstral Filter) for sign information. The proposed disparity information- extracting algorithm can obtain accurate disparity value of horizontal direction and signinformation by using both the one dimension cepstral filter which uses vertical projection data of left and right Image and the two dimension cepstral filter which uses down sampled image.