• Title/Summary/Keyword: 주사

Search Result 5,835, Processing Time 0.033 seconds

Optimization of Flushing through Correlation Analysis between the Number of Flushing and Residual Activity in PET/CT (PET/CT에서 최적의 플러싱횟수를 위한 잔류방사능과의 상관분석)

  • Woo-Yeong Choi;Yeong-Sik Jee;Chang-Yong Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.701-707
    • /
    • 2023
  • In PET/CT, the injection volume of 18F-FDG directly affects the SUV(standard uptake value), which can affect the reading results. Therefore, it is important to inject the correct dose value of 18F-FDG. In this study, we performed the correlation between the residual radioactivity remaining in the syringe and catheter insertion device according to the number of flushing during 18F-FDG injection. CRC-25R dose calibrator, catheter insertion devices, 3 cc syringes and 50 cc physiological saline were used in this study, and the results were statistically analyzed. As a result, the total residual radioactivity of the syringe and catheter insertion device remained the highest at 5.84% after two flushing, and the least remained at 1.49% after five flushing. The correlation analysis results showed that the number of flushing had a negative correlation with the residual radioactivity of the syringe at -0.436 and the catheter insertion device at -0.300. As a result of one-way distributed analysis of the average according to the number of flushing, the syringe showed a significant decrease at 4 times, and the catheter insertion device showed a significant decrease at 5 times. However, considering that an average of 0.8% remains in the case of catheter insertion devices, four time flushing seems to be the most appropriate.

Receiver-Centric Spectrum Sensing for Cognitive Radio Systems (무선인지 시스템을 위한 수신기 중심 스펙트럼 센싱 기술)

  • Shin, Oh-Soon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.2
    • /
    • pp.43-48
    • /
    • 2011
  • Cognitive radio is accepted as an effective and promising approach for resolving the spectrum scarcity problem by allowing secondary users to borrow unused spectrum from primary users. A method of identifying busy and empty spectrum at the given time and space, which is called spectrum sensing, constitutes an essential element of the cognitive radio. In this paper, we propose a receiver-centric spectrum sensing scheme which attempts to detect the primary receiver rather than the primary transmitter. It is shown that the proposed receiver-centric sensing approach results in more efficient spectrum utilization than the conventional transmitter-centric sensing.

Injection Therapy for Calcific Tendinitis of Shoulder Under the Sonographic Guidance (초음파하 극상근 석회화 건염 주사 요법)

  • Nam, Ki Young;Moon, Young Lae;Yang, Kyung Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.10-13
    • /
    • 2008
  • Purpose: To evaluate the efficiency of needling and injection technique without steroid for symptomatic calcific tendinitis of the shoulder. Material and Methods: We chose 12 symptomatic calcific tendinitis patients, whose ages ranged from 35 to 64. Procedure ware dry needling and injection of prolotherapic agent near the lesion. Results: All the case revealed prominent improvement without limitation of shoulder function, especially in active painful stage. Conclusion: Sonographic injection technique for calcific tendinitis would be one of the good modality not only for symptomatic relieve but also good functional recovery.

  • PDF

Sub-pixel Motion Compensated Deinterlacing Algorithm (부화소 단위의 움직임 정보를 고려한 순차 주사화)

  • 박민규;최종성;강문기
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.5
    • /
    • pp.322-331
    • /
    • 2003
  • Advances of high-definition television(HDTV) and personal computers call for the mutual conversion between interlaced signal and progressive signal. Especially, deinterlacing which is known as an interlaced to progressive conversion has been recently required and investigated. In this paper, we propose new deinterlacing algorithm considering sub-pixel motion information. In order to reduce the error of motion estimation, we analyze the effect of inaccurate sub-pixel motion information and model it as zero-mean Gaussian noises added respectively to each low resolution image(field). The error caused by inaccurate motion information is reduced by determining regularization parameter according to the error of motion estimation in each channel. The validity of the proposed algorithm is demonstrated both theoretically and experimentally in this paper.

Near field scanning optical interferometer using facet reflection of a tapered optical fiber (광섬유 탐침의 반사를 이용한 파면 분석 근접장 주사 광간섭계)

  • 유장훈;임상엽;이현호;박승한
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.248-253
    • /
    • 2004
  • We propose a near- field scanning optical interferometer (NSOI) based on the facet reflection of a nano-sized moveable tapered optical fiber. The interferometer can measure the position and the wave-front of a focused spot simultaneously. The interfering fringes are generated by the reflected beams from the sample surface and from the fiber facet. The wave-front analysis at the focusing position is obtained by using a phase shifting technique with a four-step algorithm. It is found that the resolution for controlling the focal position of our proposed NSOI is less than λ/3 and the measured wave-front aberration at the focal position is in good agreement with the ones obtained by a Twyman-Green interferometer.

New Edge Dependent Deinterlacing Algorithm Based on Horizontal Edge Pattern (수평 방향 에지의 패턴을 고려한 순차주사화 알고리즘)

  • 박민규;이태윤;강문기;오상근
    • Journal of Broadcast Engineering
    • /
    • v.8 no.4
    • /
    • pp.492-500
    • /
    • 2003
  • In this paper, we propose a new deinterlacing algorithm which is an edge dependent Interpolation (EDI) algorithm based on a horizontal edge pattern. Generally, a conventional EDI algorithm has a visually better performance than any other deinterlacing algorithm using one field. However, it produces unpleasant results due to the failure of estimating edge direction. In order to exactly detect edge direction, we use not only simple difference but also edge patterns. Experimental results indicate that the proposed algorithm outperforms conventional approaches with respect to both objective and subjective criteria. Index Terms I-to-P conversion, deinterlacing, edge dependent interpolation, edge pattern.

Economic evaluation of a weekly administration of a sustained-release injection of recombinant human growth hormone for the treatment of children with growth hormone deficiency (소아 성장호르몬결핍증 치료에 사용되는 성장호르몬 서방형 주사제의 경제성 평가)

  • Kang, Hye-Young;Kim, Duk Hee;Yang, Sei-Won;Kim, Yoon-Nam;Kim, Miseon
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.11
    • /
    • pp.1249-1259
    • /
    • 2009
  • Purpose:From a societal perspective, we evaluated the cost-effectiveness of a novel sustained-release injection of recombinant human growth hormone (GH) administered on a weekly basis compared with that of the present daily GH injection for the treatment of children with GH deficiency. Methods:Health-related utility for GH therapy was measured based on the visual analogue scale. During July 2008, caregivers of 149 children receiving GH therapy form 2 study sites participated in a web-based questionnaire survey. The survey required the caregivers to rate their current subjective utility with daily GH injections or expected utility of weekly GH injections. Because there was no difference in the costs of the daily and weekly therapies, for the purposes of this study, only drug acquisition costs were considered. Results:Switching from daily to weekly injection of GH increased the utility from 0.584 to 0.784 and incurred an extra cost of 4,060,811 Korean won (KW) per year. The incremental cost-utility ratio (ICUR) for a base case was 20,305,055 KW per quality-adjusted life year (QALY) gained. Scenario analyses showed that the ICUR ranged from 15,751,198 to 25,489,929 KW per QALY. Conclusion:The ICUR for a base case and worst case scenario analyses ranged from 0.85 to 1.37-times per capita gross domestic product of Korea, which is considered to be within the generally accepted willingness-to-pay threshold. Thus, it is concluded that switching from daily to weekly injection of GH would be cost-effective.

Trends of AIDS in the World and the Status of its Control in Korea (AIDS의 세계적 추세와 우리나라의 관리현황)

  • 이성우
    • Korean Journal of Health Education and Promotion
    • /
    • v.5 no.1
    • /
    • pp.1-5
    • /
    • 1988
  • AIDS란 성적 접촉에 의하여 사람에서 사람에게로 전염되었거나 금지된 마약이나 각성제등의 정맥주사에 쓰이는 주사기나 주사침을 공용하여 전염되는 것이 주인 감염경로에 의하여 일어나는 일련의 병의 최종적인 상태를 말한다. 1981년6월5일자 MMWR지에 실린 미국 로스엔젤레스지역 5명의 남성동성애자에 발생된 카리니폐염의 보고가 첫 보고증예이나, 이보다 앞선 2년반사이에 미국의 뉴욕주와 캘리포니아주에서 남성동성애자에서 카포시육종이나 카리니폐염환자가 발생되었었음이 알려져 이 병이 주목받게 되었다.

  • PDF

형질전환돼지의 과배란 유기시 성호르몬의 변화

  • 이현기;이풍연;박진기;이연근;장원경
    • Proceedings of the KSAR Conference
    • /
    • 2004.06a
    • /
    • pp.219-219
    • /
    • 2004
  • Human erythropoietin (hEPO) 유전자가 도입된 형질전환돼지는 수태와 임신율을 일반돼지와 비교를 해 보았을 때 매우 낮은 경향을 보이는 것으로 나타났으며, 이러한 경향의 원인을 구명하기 위하여 인위적인 발정동기화 및 호르몬을 이용한 과배란 유기시 배란과 수정(수태)시 성호르몬 변화를 비교하고자 실시하였다. 먼저 발정동기화를 위하여 PG 600 (PMSG 400 IU, HCG 200IU)을 주사한 후 10일 후에 Regumate porcine을 6일간 급여한 후에 PMSG 주사하고 2일 후에 hCG 주사한 다음 인공수정을 실시하였다. (중략)

  • PDF

Meta Heuristic for Calibration of Scanning Electron Microscope (주사 전자 현미경의 보정작업을 위한 메타 휴리스틱 알고리즘)

  • Lee, Sangwook
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.535-536
    • /
    • 2011
  • 주사전자현미경은 시편의 표면형상을 수 nm의 정밀도로 관찰할 수 있는 측정 장비로, 과학 기술 및 산업 분야에서 널리 사용되고 있다. 이러한 주사현미경은 30여종 이상의 변수조합에 의해 운영되며, 정상적인 영상을 관찰하기 위해서는 변수를 최적화하는 보정작업을 필요로 한다. 본 논문에서는 이러한 보정작업을 용이하게 하기 위한 메타 휴리스틱 기법을 소개한다.

  • PDF