• Title/Summary/Keyword: 주변부 지하수

Search Result 78, Processing Time 0.026 seconds

Occurrences of Uranium and Radon-222 from Groundwaters in Various Geological Environment in the Hoengseong Area (횡성지역 다양한 지질환경에서 지하수 중 우라늄 및 라돈-222 산출특성)

  • Jeong, Chan Ho;Yang, Jae Ha;Lee, Yu Jin;Lee, Yong Cheon;Choi, Hyeon Young;Kim, Moon Su;Kim, Hyun Koo;Kim, Tae Seong;Jo, Byung Uk
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.557-576
    • /
    • 2015
  • Groundwaters in granite, gneiss, and two-mica granite formations, including faults, in the Hoengseong area are examined to determine the relationship between their uranium and radon-222 contents and rock types. The chemical compositions of 38 groundwater samples and four surface water samples collected in the study area were analyzed. Sixteen of the samples showing high uranium and radon-222 contents were repeatedly analyzed. Surface radioactivities were measured at 30 points. The uranium and radon-222 concentrations in the groundwater samples were in the ranges of 0.02-49.3 μg/L and 20-906 Bq/L, respectively. Four samples for uranium and 35 samples for radon had concentrations exceeding the alternative maximum contaminant level of the US EPA. The chemical compositions of groundwaters indicated Ca(Na)-HCO3 and Ca(Na)-NO3(HCO3+Cl) types. The pH values ranged from 5.71 to 8.66. High uranium and radon-222 contents in the groundwaters occurred mainly at the boundary between granite and gneiss, and in the granite area. The occurrence of uranium did not show any distinct relationship to that of radon-222. The radon-222, an inert gas, appeared to be dissolved in the groundwater of the aquifer after wide diffusion along rock fractures, having been derived from the decay of uranium in underground rocks. The results in this study indicate that groundwater of neutral or weakly alkaline pH, under oxidizing conditions and with a high bicarbonate content is favorable for the dissolution of uranium and uranium complexes such as uranyl or uranyl-carbonate.

A Study on Behaviour of Tunnel Considering the Location of Groundwater Leaching and Fault Fracture Zone under Tunnel Construction (지하수 용출과 단층파쇄 위치에 따른 터널 거동 연구)

  • Son, Yongmin;Kim, Nagyoung;Min, Kyungjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.12
    • /
    • pp.37-43
    • /
    • 2015
  • Ground characteristics is important in tunnel structure utilizing the strength of underground. In the case of the fault fracture zone such as weak soil conditions exists in the tunnel section and groundwater leaching occurs at the same time, it happens to occur to excessive displacement or collapse of tunnel frequently. Fault fracture zone is an important factor that determines the direction of displacement and the collapse of the tunnel under construction. Behavior of fault fracture zone is determined depending on the size and orientation of the surface portion of the tunnel. If the groundwater occurs in the face of tunnel, groundwater causes displacement and collapse. And the collapse characteristics of tunnel is a major factor in determining that the time-dependent behavior. It is difficult to accurately predict groundwater leaching from the fault fracture zone in the numerical analysis method and analyze the interaction behavior of groundwater and fault fracture zone. Therefore numerical analysis method has limitations the analysis of ground water in the ground which the fault fracture zone and groundwater occurs at the same time. It is required to comprehensively predict the behavior of tunnel and case studies of tunnel construction. Thus, the location of fault fracture zone is an important factor that determines the direction of displacement and the collapse of the tunnel. In this study, behavior characteristics of the tunnel according to the location of the fault fracture was analyzed.

국내 가행광산 채굴적 활용 방안

  • 윤철헌
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.11a
    • /
    • pp.213-234
    • /
    • 2002
  • 우리 나라는 70년대까지 광업은 부흥하였으나, 그 이후 급속히 위축되면서 80년대 이후 거의 대부분 광산들이 폐광 또는 휴광된 실정이다. 그 결과 현재 전국 각지에 다수의 폐갱도가 존재하게 되었으며, 이제는 지반침하 및 각종 침출수의 원인자로 간주될 정도이다. 최근 지자체에서는 이런 폐갱도를 지역 자원으로서 가치를 인정하고 지역 활성화를 위해 재 이용하려는 움직임이 보이고 있는데, 구체적으로는 관광시설, 연구시설, 농업생산시설, 저장시설, 폐기물처리시설 등이다. 일본은 폐광된 금속광산 재활용을 위해 입지여건과 주변지역, 입갱 가능성 등 기초조사를 하였다. 조사결과 폐갱도의 문제점으로 입갱이 가능한 광산이 적다는 점을 들 수 있다. 대부분의 광산은 갱구가 함몰되었거나, 갱내에 지하수가 차 있어 접근이 불가능한 경우가 대부분이다. 비교적 양호한 암반 경우는 서브 레벨 스토핑, 잔주, 주방식 등의 채굴법에 의해 대규모 공동이 잔존하고 있는 경우도 있지만 그리 많지 않았다. 폐광된 광산 재활용 여건은 우리 나라와 일본이 대동소이 경우로 현실적으로 활용이 가능한 폐광은 많지 않으며 활용코자 할 때에는 기존갱도를 활용하면서 암반이 견고한 곳에 새로운 갱도를 설치하여야 한다. 그러나 몇몇 곳에서는 매우 유용하게 잘 활용되고 있는 곳도 있고, 연구 검토하면 충분한 활용성이 있다고 생각되는 곳도 있다. 그러므로 현재의 상황을 보고 판단할 것이 아니라, 활용기술과 접목해서 활용성을 검토함으로써 불용 자산의 유용화 방안이 검토되어야 할 것이다. 현재 가행중인 광산은 입지여건 및 암반이 양호하고, 대형갱도를 굴착하는 석회석광산 등을 선택하여 폐광 후 활용이 가능토록 채광기술 발전시켜 나가야 하며, 인간 중심적인 시설 또는 산물 중심적인 시설로 구분하여 폐광 후 복구비용을 우선 지원하는 방식 등을 통하여 시추, 탐광굴진, 현대화, 수갱굴착, 자금융자 등을 지원하는 우리 공사와 산업자원부가 지자체, 산림청, 건교부, 농림부 등과 연계하여 종합적인 지원육성책을 마련하여야 할 것이다. 결과적으로, 지방자치단체 등에서 관심을 갖고 있는 저장시설, 폐기물처리시설, 관광시설, 농업생산시설, 연구시설 등을 중심으로 '광산 채굴적을 미래에 어떻게 활용한 것인가'를 선진외국 사례를 벤치마킹하고, 연구ㆍ검토하여 친환경적인 광산개발이 되도록 기본적인 방향과 개념을 갖도록 하여 관련 정책을 계획적이고, 체계적으로 수립 일관성 있게 추진해 나가야 할 것이다.

  • PDF

Effect of Groundwater Flow on the Behavior of Circular Vertical Shaft (지하수 유동을 고려한 원형수직구 거동분석)

  • Park, Heejin;Park, Jongjeon;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.6
    • /
    • pp.29-39
    • /
    • 2022
  • This study investigates the behavior of a circular vertical shaft wall in the absence and presence of a groundwater table. The effects of wall deflection, backfill settlement, and earth pressure distribution around the circular vertical shaft caused by sequential excavations were quantified. The vertical shaft was numerically simulated for different excavation depths of the bearing layer (weathered soil, weathered rock, soft rock) and transient and steady-state flows in the absence of a groundwater table. The backfill settlements and influential area were much larger under transient flow conditions than in steady-state flow. On the contrary, the horizontal wall deflection was much larger in steady state than in the transient state. Moreover, less settlement was induced as the excavation depth increased from weathered soil to weathered rock to the soft rock layer. Finally, the horizontal stresses under steady- and transient-state flow conditions were found to exceed Rankine's earth pressure. This effect was stronger in the deeper rock layers than in the shallow soil layers.

Numerical study for the optimum grouting design of subsea tunnels (해저터널의 그라우팅 최적 설계를 위한 수치해석적 연구)

  • Joo, Eun-Jung;Kim, Yong-Kye;Shin, Jong-Ho;Kwon, Oh-Yeob
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.5
    • /
    • pp.349-358
    • /
    • 2010
  • In the long-term, most tunnels suffer from the increase in ground water inflow and in pore water pressure on the lining. To reduce such hydraulic effect, generally grouting methods are adopted. In this paper effective grouting design is proposed based on numerical simulation. To investigate the optimal grouting layout, factors such as relative permeability, grouting thickness, and distance from the lining are considered. The results are analysed in terms of pore water pressure, inflow rate, and earth pressure. It is revealed that the pore water pressure has increased with a decrease in grout permeability, an increase in grouting thickness and an increase in grouting distance. Meanwhile the inflow rate has decreased with a decrease in grout permeability and is inversely proportional to grouting thickness. Effective grouting design guideline are proposed based on this study.

Case Study on Failure of Rock Slope Caused by Filling Material (충전물에 의한 암반사면 붕괴사례)

  • Kim, Yong-Jun;Kim, Sun-Ki;Kim, Joo-Hwa
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.87-90
    • /
    • 2007
  • 셰일층으로 구성된 암반사변에서 층리면을 따라 대규모 평면파괴가 사연 중앙부에서 발생하였다. 현장조사시 파괴사면 주변은 지하수 누수 흔적과 점토층의 충전물이 존재하였으며, 파괴원인을 검토한 결과 층리면을 따라 형성된 점토 충전물의 낮은 전단강도와 강우시 인장균열내 형성된 수압에 의해 붕괴가 발생한 것으로 나타났다. 그리고 충전된 절리면의 전단강도 특성을 규명하기 위해서 모래, 점토의 인위적인 충전물을 이용하여 충전재 두께비에 따른 전단강도 특성을 고찰하였다.

  • PDF

Delineation of internal heterogeneities of Geum River point bar deposits in Buyeo area using GPR Data (지하 투과 레이다 조사를 통한 부여 지역 금강변의 충적 대수층 내부 불균질성 파악)

  • Rhee, Chul-Woo;Kim, Hyoung-Soo;Lee, Kyung-Joo
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.4
    • /
    • pp.337-344
    • /
    • 2002
  • The alluvial deposits along meandering rivers can be used as an artificial aquifer for infiltration of river waters. Internal heterogeneity of the alluvial deposits is a prerequisite information for the development of alluvial groundwater because vortical and lateral movement of alluvial ground water depends on the internal heterogeneity The internal heterogeneity due to variations in channel behavior can be delineated using GPR survey, GPR profiles for the point bar deposits near Buyeo county reveals two different stratigraphic units: the lower inclined heterogeneous strata and the upper horizontally stratified strata. The upper unit is largely indicative of vertical accumulation by overbank floods within a floodplain, whereas the lower one represents typical point bar deposits formed by lateral accretion. The stratigraphic variation in the heterogeneity shows that GPR survey is a useful and necessary investigation method for the development of alluvial ground water.

  • PDF

Geophysical Explorations for Safety Analysis of Bangeosan-Maaebul(Stone Relief Bhaisajyaguru triad at Mt. Bangeosan) (방어산 마애여래입상의 안전진단을 위한 지구물리탐사)

  • O, Seon-Hwan;Seo, Man-Cheol
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • Seismic refraction and electrical resistivity surveys were conducted in Bangeosan Maaebul site located in Haman, Kyungnam, in order to present geophysical safety analysis method for masonry cultural properties. Seismic refraction exploration revealed that the ground was composed of three layers in term of seismic wave velocity; the upper, medium, and lower layers. The low velocity ranging from 308 to 366 m/sec in upper layer suggests weathered soil, the intermediate velocity from 1906 to 2090 m/sec in the medium layer indicates weathered rocks, and the high velocity from 5061 to 5650 m/sec in the lower layer implies extremely hard rocks. Our seismic result suggests that the upper and medium layer around the Maaebul should be reinforced to support the construct. The result of electric resistivity survey shows that there exists a low resistivity zone, ranging from 131 to 226 Ohm-m, at the right side of the Maaebul with the direction of NE-NNE. This area is the weakness zone as it plays role of the underground water passage in rainy season.

  • PDF

Case Study of Remidation and Investigation of Closed Unsanitary Landfill for Prevention of Leachate (비위생매립지 정밀조사 및 침출수 방지를 위한 정비방안 연구)

  • Kim, Sangkeun;Lee, Yongsoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.5-13
    • /
    • 2012
  • For the last decade the amount of waste has rapidly been increased in South Korea and many waste landfills have been built according to government guidelines specifying required systems such as landfill liner, leachate collecting facilities, final cover system, etc. This effort has led the recently constructed landfills to be under well managed sanitary condition. In a meanwhile closed waste-landfill sites in the past before the adoption of the government guidelines exits under unsanitary condition. In these cases untreated leachate flew out to the surroundings due to the absence of liner and leachate collecting facilities and caused groundwater and soils to be contaminated. Waste generated odor and gas also brought civil complaints. Because environmental influences bring serious problems nearby sites, it is required to have unsanitary waste-landfills to be appropriately treated and managed. A study to evaluate environmental influence and contamination level of surroundings nearby and on the unsanitary landfills is necessary before the establishment of "Management guide of closed landfill site." This paper presents an environmental evaluation for the closed site, Doil-dong landfill, according to "Closed landfill management regulation" by Ministry of Environment. "D" landfill, located in Pyeongtaek city, has possobility to contaminate surrounding surfacewater and groundwater by leakage of leachate. The in-situ stabilization carried out to build the DMW(deep soil mixing cutoff wall) wall and drainage systems.

An Assessment of the Excavation Damaged Zone in the KAERI Underground Research Tunnel (원자력연구원 내 지하처분연구시설의 암반 손상대 발생영향 분석)

  • Kim, Jin-Seop;Kwon, Sang-Ki;Cho, Won-Jin
    • Explosives and Blasting
    • /
    • v.27 no.1
    • /
    • pp.21-31
    • /
    • 2009
  • An excavation damaged zone (EDZ) is created by fracturing, excavation or stress redistribution of tunnels. In this zone the mechanical and hydraulic properties of rock are changed, which makes additional cracks and serves as a dominant pathway of groundwater flow. In this study, an assessment on an EDZ size was practiced by the measurement of the deformation modulus at the KAERI underground research tunnel (KURT), and the information was applied to the modelling analysis using FLAC2D software. The EDZ at KURT fell into the range of 0.6~1.8m and the deformation moduli of the EDZ generally correspond to about 40% of intact rock mass. With a consideration of the EDZ in numerical analysis, tunnel displacements increased by about 65% and the maximum principal stress decreased to 58% from the case without EDZ. The plastic zone of the tunnel was enlarged to the crown and invert zones of the tunnel within the range of the length of rock bolts. About 2% of the total tunnel displacement with EDZ was suppressed by the KURT support system. It is anticipated that the investigation of an EDZ can be used as an important and fundamental research for validating the overall performance of a high level waste disposal system.