• Title/Summary/Keyword: 주름진 판

Search Result 2, Processing Time 0.018 seconds

Analysis of Corugated Surface Wave Antenna Using Hybrid MOM/UTD Method (하이브리드 MOM/UTD 방법을 이용한 주름진 표면파 안테나의 해석)

  • Kim, Joong-Pyo;Lee, Chang-Won;Son, Hyon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.3
    • /
    • pp.359-367
    • /
    • 1999
  • The analysis of a surface wave antenna with the corrugated ground plane fed by a parallel-plate waveguide is considered. An equivalent theorem Is employed to subdivide the original problem into three regions for the simple analysis : one concerning the geometry inside the shorted parallel-plate(Internal region 1), one concerning the geometry of the corrugation(Internal region 2), and one concerning the geometry of the conducting wedge(External region). The hybrid method of moment(MOM)/uniform geometrical theory of diffraction(UTD) method is applied to analyze a corrugated surface wave antenna with the end-fire radiation. Our numerical results are very well matched with those of the previous experiment, better results are obtained when compared with those of the previous simple equivalent current approach. Also, we can obtain the parameters to design an effective end-fire corrugated surface wave antenna.

  • PDF

Experimental measurements of R-22 two-phase friction factor in plate heat exchangers (판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가)

  • Yoo, Sang-Roon;Jeong, Ji-Rwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF