Total Elbow Arthroplasty for the Fracture of Elbow Arthrodesis Site - A Case Report - (주관절 전치환술로 치료한 주관절 관절 고정술 부위의 골절 - 증례 보고 -)

  • Kim, Myung-Ho;Seo, Joong-Bae;Hwang, Sung-Su
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.246-250
    • /
    • 2007
  • Total elbow arthroplasty is a relatively rare procedure compared with total knee or total hip arthroplasty. Total elbow arthroplasty for bony ankylosis is even rarer, and the results are often unsatisfactory. We report a patient who gained good mobility of the elbow after total elbow arthroplasty for the treatment of fractured arthrodesis site with which the patient had lived with for 12 years.

Total Elbow Arthroplasty after Failed Surgical Treatment for Elbow Fracture or Dislocation (주관절 골절 혹은 탈구의 실패한 수술적 치료 후 시행한 주관절 전 치환술의 결과)

  • Yi, Jin-Woong;Roh, Jun-Ha;Song, Jong-Hoon;Rhee, Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.190-198
    • /
    • 2007
  • Purpose: The current study reports the clinical results of total elbow arthroplasties (TEA) which were Performed on patients with poor clinical and radiological results after initial surgeries for elbow fractures or dislocations. Materials and Methods: The clinical outcomes of twelve consecutive patients who underwent TEA after failed surgeries for elbow fractures or dislocations from january, 1995 to December, 2005 were evaluated. The initial diagnoses were distal humeral fractures in 8 cases and fracture-dislocations in 4 cases. The Mean period from the initial operations to the TEAs was 12 months. The mean folloow up period after TEA was 43 months. Results: The mean range of motion, in terms of active extension, activeflexion, supination, and pronation, improved from $14.2^{\circ}$, $96.7^{\circ}$, $50.8^{\circ}$ and $53.3^{\circ}$ to $5.4^{\circ}$, $122.1^{\circ}$, $63.3^{\circ}$ and $67.5^{\circ}$, respectively (p<0.05). RAdiolucent lines were found in 3 cases, which were 1 case of type 3, and 2 cases of type 4. All three loosening cases underwent revision TEAs. The mean postoperative Mayo elvow performance score was 79 point. There were 6 cases of excellent, 2 cases of good, and 4 cases in poor. Conclusion: Good clinical results were obtained after TEA performed in failed surgeries for elbow fractures of dislocations.

Metallic Radial Head Prosthesis in Korea (요골두 금속 치환물의 국내 사용)

  • Han, Sang-Hwan;Moon, Jun-Gyu;Park, Jong-Wong;Jang, Ki-Mo
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.84-91
    • /
    • 2007
  • Purpose: The aim of this study was to report seven cases of metallic radial head prosthesis and present the limit of use in Korea. Materials and Methods: Metallic radial head arthroplasty was performed on 7 patients between April 2006 and December 2006, who had complex elbow injury including comminuted radial head fracture. Indication, operative findings and outcome were assessed. Availability and payment of implant were investigated. Results: All of the patients had more than one associated injury including coronoid fracture, olecranoan fracture, and ligament ruptures. According to Mason classification, there were three type III and four type IV fractures. All radial head fractures were too comminuted to reconstruct. There were two excellent results, four good, and one poor, as graded by Mayo score. There were no patient with instability and implant related complications. Insufficient supply of implant did not enable to do scheduled surgery in 2 cases. Current medical insurance did not cover charge for radial prosthesis, five patients could not help paying for that by themselves. Conclusion: Metallic radial head implants are useful when the radial head cannot be repaired reliably. Preoperative preparing and coverage by medical insurance based on appropriate indication are helpful for decision for a treatment option.