• Title/Summary/Keyword: 주거용

Search Result 501, Processing Time 0.022 seconds

Effects of Street Centrality on the Land Prices in Seoul, South Korea (서울시 가로망 중심성의 토지가격 효과 연구)

  • Kang, Chang Deok
    • Korea Real Estate Review
    • /
    • v.27 no.3
    • /
    • pp.51-70
    • /
    • 2017
  • This study aimed to measure street centralities with the street width, and to analyze their effects on the residential and non-residential land prices in Seoul, South Korea. Most of the studies on urban economics and policy focusing on the urban spatial structure have evolved in terms of their perspective from monocentric to polycentric models. Recently, their themes shifted to measuring street centralities and capturing their effects on urban phenomena. To expand the existing studies and discussion, this study analyzed the street centralities with the street width, and how they changed the land prices. Multilevel regression models generated a few key findings relevant to the relationship between street centralities and land prices. While a higher detour volume and closeness to wider streets commanded premium residential land prices, higher visibility and detour volume to wider streets were associated with higher non-residential land prices. These findings suggest a robust connection between street configuration and near-land prices. Thus, the results of this study suggest a few insightful policy implications for urban planners, urban designers, real estate developers, and appraisers.

Representation of Population Distribution based on Residential Building Types by using the Dasymetric Mapping in Seoul (대시메트릭 매핑 기법을 이용한 서울시 건축물별 주거인구밀도의 재현)

  • Lee, Sukjoon;Lee, Sang Wook;Hong, Bo Yeong;Eom, Hongmin;Shin, Hyu-Seok;Kim, Kyung-Min
    • Spatial Information Research
    • /
    • v.22 no.3
    • /
    • pp.89-99
    • /
    • 2014
  • The aim of this study is to represent the residential population distribution in Seoul, Korea more precisely through the dasymetric mapping method. Dasymetric mapping can be defined as a mapping method to calculate details from truncated spatial distribution of main statistical data by using ancillary data which is spatial data related to the main data. In this research, there are two types of data used for dasymetric mapping: the population data (2010) based on a output area survey in Seoul as the main data and the building footprint data including register information as ancillary spatial data. Using the binary method, it extracts residential buildings as actual areas where residents do live in. After that, the regression method is used for calculating the weights on population density by considering the building types and their gross floor areas. Finally, it can be reproduced three-dimensional density of residential population and drew a detailed dasymetric map. As a result, this allows to extract a more realistic calculating model of population distribution and draw a more accurate map of population distribution in Seoul. Therefore, this study has an important meaning as a source which can be applied in various researches concerning regional population in the future.

Environmental Support of Independent Elderly Households in Senior Housing Cooperatives (미국 노인전용 조합주택의 거주환경 평가)

  • Lee, Hyunjeong
    • Journal of the Korean housing association
    • /
    • v.14 no.5
    • /
    • pp.57-64
    • /
    • 2003
  • 본 연구의 목적은 최근 건설된 노인전용 조합주택으로 입주한 노인가구를 대상으로 거주자 측면에서의 주거환경 평가이며, 아울러 미국 조합주택에 대한 이해를 도모하고자 한다. 설문지를 통해 수집한 자료는 빈도와 백분율 회귀분석을 사용하여 분석하였으며, 총 171가구가 본 조사에 참여하였다. 조사대상 가구주의 평균 연령은 76세였으며 교육 수준은 높았고, 가족형태는 부부나 독남가구가 대다수였다. 조사에 참여한 가구들은 저렴한 주택비용, 안전성, 주택유지 및 관리의 용이성, 주거 내의 접근용이성을 현 주거환경의 선택 동기로 손꼽았다. 현 주거환경의 평가를 물리적 환경, 사회적 환경, 그리고 거주자 참여방식의 관리에 대한 만족도로 크게 3가지로 나뒀으며, 물리적 환경 관련 요소가 주거환경 평가와 관련한 만족도에 가장 중요하게 작용하였다. 본 연구결과는 장기적인 주택관련 비용의 저렴화와 노인의 독립성을 위한 지원성이 강화된 물리적인 환경의 구축이 무엇보다 주거환경 평가시 중요하므로, 향후 노인전용 대안주택 계획시 이점에 대해 고려되어야 할 것이다.

A Study on the Adequacy Evaluation of Criteria of Occupant Load Factor in Residential Buildings (주거용 건축물의 재실자밀도 기준 적정성 평가에 관한 연구)

  • Seo, Dong-Goo;Hwang, Eun-Kyoung
    • Journal of the Korean housing association
    • /
    • v.27 no.6
    • /
    • pp.145-153
    • /
    • 2016
  • The purpose of this study is to grasp the effectiveness of evacuation safety design by verifying the appropriateness of the standard of occupant load factor for residential buildings. To this end, the definition and current standard of occupant load factor for residential buildings were analyzed, and the problems of the current standard were clarified by interviewing professionals. In addition, changes in occupant load factor were examined by year based on statistical research, and evaluation on the current standard $18.6m^2/pers.$ was performed. As for evaluation methods, the need of redesigning of evacuation capacity was investigated by using evacuation simulation. As a result of the analysis, the most serious problem was clarification of the applicable standard for residential officetel, where the average occupant load factor was $26.1m^2/pers.$, which was not appropriate. However, as a result of evaluation on evacuation capacity, although there was no difference between statistical research results and the current standard in terms of evacuation capacity, when the standard for business facilities was applied to officetel, evacuation time doubled. Thus, this study suggests that when the current standard is applied to residential officetel, it is necessary to separate between residential use and business use.

A Study on the Heating Performance of SCW Type Geothermal Heat Pump System for Residential House (지하수 이용 지열 히트펌프 시스템의 주거용 건물 적용시 난방성능 특성에 관한 연구)

  • Kim, Ju-Hwa;Kim, Ju-Young;Hong, Won-Hwa;Ahn, Chang-Hwan
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.11-18
    • /
    • 2008
  • Geothermal heat pump system using sanding column well type with their ground heat exchanger can be used as a highly efficient source of heating and cooling in massive buildings. But there is no case of a small scale residential house. So in the residential house this study estimated heating coefficient of performance (COP) of geothermal heat pump system using sanding column well type which is excellent in heat recovery. As a result of analysis, The COP of heat pump is over average 6 and is excellent. And in consequence of making a comparative study according to the bleeding, the COP is higher in the case of bleeding. Therefore, bleeding affects the performance of the system. This study has shown performance result that stands on actual data. Therefore, this study provides ground data that needs when a low capacity of system designs for a residence with confidence elevation.

A Study on the Design Method of Cold & Hot Water Manifold System for Residential Buildings through the Piping Network Analysis (관망해석을 통한 주거용 건축물의 급수.급탕 헤더시스템 설계 방안에 관한 연구)

  • Cha, Min-Chul;Seok, Ho-Tae;Kim, Dong-Woo
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.111-120
    • /
    • 2008
  • The aim of this study is to present the design methods about manifold location being installed and size and to draw out the proper piping size as comparing the fluctuation of discharge with manifold size and residence size through the piping network analysis, when using the same faucet in accordance. The findings are summarized as follows, 1) an appropriate header main body pipe diameter was deemed to be $32{\sim}50\;mm$. 2) the research presented design measures for the application of appropriate water supply inlet pipe diameters according to residential buildings with various sizes. 3) the header direct branch piping method is ideal for small and medium-sized residential complexes, and the header branching and semi header methods are deemed to be more favorable for large residential complexes. 4) this study offered design measures for appropriate header system main body pipe diameters, water supply inlet pipe diameters, header system piping methods, application methods for functional auxiliary equipment units, and header system installation spaces and location.