• Title/Summary/Keyword: 좌굴평가

Search Result 295, Processing Time 0.024 seconds

Study on Local Buckling of District Heating Pipes Using Limit State Design (한계상태 설계법을 이용한 지역난방 열배관의 국부좌굴 연구)

  • Kim, Joo-Yong;Lee, Sang-Youn;Ko, Hyun-Il;Cho, Chong-Du
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1829-1836
    • /
    • 2010
  • The district heating system distributes the heat generated from a cogeneration plant to wider locations. In this process, the district heating pipe (DHP) is subjected to internal and external loadings. The internal loadings are generally caused by the operating conditions such as water temperature and internal pressure. Frictional interactions between the pipes and the soil contribute to the external loadings. Thus, investigation of the mechanisms of failure of DHPs will help to guarantee both mechanical stability and heating efficiency. In this study, we investigate the local buckling of DHPs using limit state design (LSD). Two methods are considered: the use of the limit state for the width-thickness ratio and the use of the limit state for the strain. The results are used to confirm that the DHP is stable under local buckling. Finally, we suggest a minimum preheating temperature for avoiding local buckling.

Comparison of Wind Load Provisions Based on the Wind Buckling Behaviors of Plant Tank (플랜트 탱크의 좌굴 거동에 근거한 풍하중 설계기준 비교 연구)

  • Bae, Doobyong;Park, Il Gyu;Park, Jang Ho;Oh, Chang Kook
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.203-211
    • /
    • 2016
  • There are no consistent wind load provisions to design the plant tank in Korea. To suggest the appropriate design wind load, five kinds of specifications including KS B 6283, API 650, ASCE 7-10, EN 1991-1-4 are compared. To evaluate the adequacy of wind load specification in each code first, pressure coefficients were calculated in each code and compared with the results of wind tunnel test. Finite element analyses using linear bifurcation analysis were performed with the parameter of h/d and f/d (h : height of cylinderical part of tank, f : roof heigh, d : diameter of tank). By analyzing the results, appropriate wind load criteria which reflects the real wind actions and easy to apply will be suggested.

Hysteresis Characteristics of Buckling Restrained Brace with Precast RC Restraining Elements (조립형 프리캐스트 콘크리트 보강재를 가지는 비좌굴가새의 이력특성)

  • Shin, Seung-Hoon;Oh, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.72-84
    • /
    • 2016
  • The conventional brace system is generally accepted as the lateral load resisting system for steel structures due to efficient story drift control and economic feasibility. But lateral stiffness of the structure decreases when buckling happens to the brace in compression, so that it results in unstable structure with unstable hysteresis behavior through strength deterioration. Buckling restrained brace(BRB) system, in which steel core is confined by mortar/concrete-filled tube, represents stable behavior in the post-yield range because the core's buckling is restrained. So, seismic performance of BRB is much better than that of conventional brace system in point of energy absorption capacity, and it is applied the most in high seismicity regions as damper element. BRBs with various shaped-sections have been developed across the globe, but the shapes experimented in Korea are now quite limited. In this study, we considered built-up type of restraining member made up of precast reinforcement concrete and the steel core. we experimented the BRB according to AISC(2005) and evaluated seismic performances and hysteresis characteristics.

A Study on the Evaluation of Tension-Compression Fatigue Characteristics of Glass Fiber/Epoxy 4-Harness Satin Woven Laminate Composite for the Railway Bogie Application (철도차량 대차 적용 유리섬유/에폭시 4-매 주자직 적층 복합재의 인장-압축 피로특성 평가 연구)

  • Jeon, Kwang-Woo;Shin, Kwang-Bok;Kim, Jung-Seok
    • Composites Research
    • /
    • v.23 no.5
    • /
    • pp.22-29
    • /
    • 2010
  • This paper describes the evaluations of tension-compression fatigue characteristics and life for glass fiber/epoxy laminate composite applied to railway bogie to reduce weight. Test samples of tension-compression fatigue were composed of glass fiber/epoxy 4-harness woven laminate composites with different stacking sequence of warp-direction, fill-direction and ${\pm}45^{\circ}$-direction. The tension-compression fatigue test was conducted with stress ratio (R) of -1 and frequency of 5Hz. Goodman diagram were used to evaluate the fatigue characteristics and life of glass fiber/epoxy 4-harness satin woven laminate composite. Anti-buckling jig was designed to prevent buckling of specimen under compression load. The test results showed that the fatigue characteristics of glass fiber/epoxy 4-harness satin woven laminate composite with stacking sequence of warp-direction had a good performance in comparison with that of SM490 used to conventional metal railway bogie.

Experimental Investigation of Lateral Retrofitting Effect with CFRP and BRB (Buckling-Restrained Brace) for Beam-column Joints of Low-Rise Piloti Buildings (탄소섬유시트와 비좌굴 가새를 이용한 저층 필로티 구조물의 보-기둥 연결부의 횡방향 보강효과에 관한 실험적 연구)

  • Seo, Sang-Hoon;Yoo, Yeon-Jong;Lee, Young-Hak;Kim, Hee-Cheul;Lee, Ki-Hak;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.45-52
    • /
    • 2009
  • The purpose of this study is to evaluate the structural capacities of beam-column specimens retrofitted with CFRP sheet and BRB (Buckling-Restrained Brace) under sustained axial and cyclic lateral loads. Three specimens were made using different retrofitting methods : non-retrofitted, retrofitted with CFRP sheets only, and retrofitted with both CFRP sheet and BRB systems. Lateral load resistant capacities were evaluated based on the load-displacement relations. From the results, the maximum lateral forces of the FRP sheet retrofitted and both the FRP and BRB retrofitted specimens showed approximately 34% and 138% improvement, respectively, compared with the non-retrofitted specimen.

Characteristic of Buckling and Ultimate Strength of the Perforated Stiffened Plate (유공보강판의 좌굴 및 극한강도 특성에 관한 연구)

  • Park Joo-Shin;Ko Jae-Yong;Oh Kyoung-Gun
    • Journal of Navigation and Port Research
    • /
    • v.30 no.6 s.112
    • /
    • pp.439-446
    • /
    • 2006
  • In ship structures many of the structural plates have cutouts, for example, at inner bottom structure, girder, upper deck hatch, floor and dia-frame etc. In the case where a plate has a cutout it experiences reduced buckling and ultimate strength and at the same time the in-plane stress under compressive load produced by hull girder bending will be redistributed In general, actual ship structure adopted reinforcement of stiffener around the cutout in order to preventing from buckling so it need to examine a buckling and ultimate strength behaviour considering a cutout because In many ship yards used class rule for calculating buckling strength but it is difficult to evaluate perforate stiffened plate with random size. In the present paper, we investigated several kinds of perforated stiffened model from actual ship and then was performed finite element series analysis varying the cutout ratio, web height, thickness and type of cross-section using commercial FEA program(ANSYS) under compressive load.

Safety Evaluation of Radiating Element by Structural Test and Stress Analysis (구조 실험 및 응력 해석을 통한 복사 소자의 안전성 평가)

  • Kim, Jin-Yul;Kim, Dong-Seob;Park, Byung-Rak;Kim, Jin-Sung;Kim, Min-Sung;Park, Chan-Yik;Hwang, Woon-Bong
    • Composites Research
    • /
    • v.26 no.4
    • /
    • pp.259-264
    • /
    • 2013
  • This study manufactured the radiating element of multi-band antenna skin structure which satisfy electrical and mechanical performance and is made by double injection molding process. Structural test including impact and buckling test is carried out and stress analysis is simulated to evaluate safety of radiating element for the axial and shear loads, when changing of the skin structure is occurred by the external force. To predict allowable load of structure and evaluate safety on impact and buckling, experimental and analytic method is used in strength analysis of structure.

Flange Local Buckling(FLB) for Flexural Strength of Plate Girders with High Performance Steel(HSB 800) (고성능 강재(HSB 800)를 적용한 플레이트 거더의 휨강도에 대한 플랜지 국부좌굴)

  • Kim, Jeong Hun;Kim, Kyoung Yul;Lee, Jeong Hwa;Kim, Kyung Sik;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.2
    • /
    • pp.91-103
    • /
    • 2014
  • High performance steel for bridges(HSB 800) with a minimum tensile stress of 800MPa was recently developed. However, the study for local buckling behavior of plate girders considering interactive effects of flanges and webs is still insufficient. In this study, the flange local buckling(FLB) strength of plate girders with HSB 800 was evaluated by nonlinear finite element analysis. The flanges and webs of plate girders having I-section were modeled as 3D shell elements in the nonlinear analysis. Initial imperfection and residual stress were imposed on the plate girder. The high performance steel was modeled as a multi-linear material. Thus, parametric study of compression flanges with a compact, noncompact and slender web was performed. The flange local buckling behavior of plate girders was analyzed, and the nonlinear analysis results were compared with the nominal flexural strength of both AASHTO LRFD(2012) and KHBDC LSD(2012) codes.

The Bucking Strength and the Application of design of Design Formula of High Strength H-Shaped Section Steel Members (고강도 H형강 부재의 좌굴내력과 설계식에의 적용에 관한 연구)

  • Kim, Jin Kyong;Kim, Hee Dong;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.2
    • /
    • pp.123-131
    • /
    • 2001
  • The objective of this study is to investigate the criteria of the width-to-thickness ratio and to evaluate the buckling strength of high strength steel beam-columns and to compare their buckling strength with design codes, which are the Limit State Design code and the Allowable Stress Desogn code(drift). SM520TMC and SM570Q class steels are used for high strength steels. The coupon test and the stub column test were carried out to investigate the properties of high strength steels and the stress-strain curves of stub columns. The buckling strength of high strength steel beam-columns are assessed by numerical analysis used axial force, moment and curvature relationships.

  • PDF