• Title/Summary/Keyword: 종양두께

Search Result 109, Processing Time 0.023 seconds

Analysis of Treatment Results of Malignant Melanoma (악성 흑색종의 치료결과 분석)

  • Shin, Duk-Seop;Kim, Ui-Sik
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 2011
  • Purpose: This study was designed to evaluate the treatment results of malignant melanoma and to analyze the factors influencing prognosis. Materials and Methods: Thirty one cases of malignant melanoma were included in this study. They were treated in our hospital surgically, medically and immunologically from January 1996 to December 2005, and were followed more than 5 years. We compared 5 year survival rate (5YSR) according to the age, gender, anatomical site, depth of tumor, TNM stage, involvement of lymph node and immuno-chemotherapy. Results: Overall 5YSR was 80.6%. 5YSR of the age group below 65 years was 89.7% and 66.7% for the age group over 65 (p=0.033). 5YSR for men was 75% and 90.9% for women. 5YSR according to the site of occurrence showed 66.7% in upper extremities, 89.5% in lower extremities, and 66.7% in other site. 5YSR was 100% for the Clark level below III and 62.5% for the level above IV (p=0.032). 5YSR was 53.8% for lymph node metastasis group and 100% for non-lymph node metastasis group (p=0.021). Conclusion: We concluded that early diagnosis and wide excision was the most important in treatment of malignant melanoma. The prognostic fractors of malignant melanoma were age, depth of tumor (Clark's stage) and metastasis of lymph node.

Dose Distribution for Eye Shielding Block In 6 MV Photon Beam Therapy (6 MV 광자선치료에서 안구차폐기구의 제작과 선량분포 측정)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.155-161
    • /
    • 1992
  • The eye lens is known to be radiosensitive organ and catarat can be induced by relatively low dose of radiation. In the treatment of head and neck tumors, shielding blocks are frequently used to minimize dose on sensitive organs. The shielding block, which is made of high atomic number materials (cerrobend), produce significant dose perturbations in megavoltage photon beams. The effects of these perturbations of eye shielding blocks are measured with film and ion chambers for the treatment of head and neck malignancies. Optimum parameters for the treatment are suggested.

  • PDF

Evaluation of Bolus Applicability through Dose Evaluation According to 3D Print Materials (3D 프린트 소재에 따른 선량평가를 통한 볼루스 적용성 평가)

  • Kim, Jung-Hoon;Lee, Deuk-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.241-246
    • /
    • 2019
  • Among the 4th Industrial Revolution technologies, evaluated bolus applicability through dose assesment according to the materials of 3D printing technology. Dose assesment was using MCNPX which was applied Monte Carlo method and 3D print materials were ABS, PC and PLA. Thus, the thickness with the same effect as the bolus 10 mm was found to be ABS 10 mm, PC 9 mm and PLA 9 mm for the 6 MeV electron. For 6 MV X-ray, ABS 11 mm, PC 10 mm and PLA 9 mm were shown. This study showed that tissue equivalent materials made from 3D printer materials can replace bolus.

A Feasibility Study on the Improvement of Diagnostic Accuracy for Energy-selective Digital Mammography using Machine Learning (머신러닝을 이용한 에너지 선택적 유방촬영의 진단 정확도 향상에 관한 연구)

  • Eom, Jisoo;Lee, Seungwan;Kim, Burnyoung
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Although digital mammography is a representative method for breast cancer detection. It has a limitation in detecting and classifying breast tumor due to superimposed structures. Machine learning, which is a part of artificial intelligence fields, is a method for analysing a large amount of data using complex algorithms, recognizing patterns and making prediction. In this study, we proposed a technique to improve the diagnostic accuracy of energy-selective mammography by training data using the machine learning algorithm and using dual-energy measurements. A dual-energy images obtained from a photon-counting detector were used for the input data of machine learning algorithms, and we analyzed the accuracy of predicted tumor thickness for verifying the machine learning algorithms. The results showed that the classification accuracy of tumor thickness was above 95% and was improved with an increase of imput data. Therefore, we expect that the diagnostic accuracy of energy-selective mammography can be improved by using machine learning.

Dose Effect of Tissue Compensator for 6 MV X-Ray (두경부 방사선조사시 3차원조직보상체에 의한 피부선량)

  • Lee, Ho-Jun;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 1992
  • It is ideal thing to compensate tissue deficit without skin contamination in curvatured irradiation field of high energy photon beam. The 3-dimensional compensating technique utilizing tissue equivalent materials to ensure an adequate dose distribution and skin sparing effect was described. This compensator was made of paraffin ($70\%$) and stearin wax ($30\%$) compound. The parameters for evaluation of the effect on skin dose in application of compensator were considered in the size of the field, the thickness of the compensator and the source-to-axis distance. The results are as follows; the skin doses were not changed even though application of the compensator, but depended on the field size and the source-to-axis distance, and the skin doses were only slightly changed within $1\%$ relative errors as increasing the thickness of the compensator in these experiments.

  • PDF

Photon Energy Dependence of the Sensitivity of LiF TLDs Loaded with Thin Material (얇은 박막을 얹은 TLD 반응감도의 광자 에너지에 대한 의존성)

  • Min Byongim J;Kim Sookil;Loh John J.K;Cho Young Kap
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.256-260
    • /
    • 1999
  • Purpose : An investigation has been carried out on the factors which affect the response reading of thermoluminescent dosimeters (TLD-100) loaded with thin material in high energy Photon. The aim of the study was to assess the energy response of TLD-100 to the therapeutic ranges of photon beam. Materials and Methods : In this technique, TLD-100 (abbreviated as TLD) chips and three different thin material (Tin, Gold, and Tissue equivalent plastic plate) which mounted on the TLD chip were used in the clinical photon beam. The thickness of each metal plates was 0.1 mm and TE plastic plate was 1 mm thick. These compared with the photon energy dependence of the sensitivities of TLD (normal chip), TLD loaded with Tin or Gold plate, for the photon energy range 6 MV to 15 MV, which was of interest in radiotherapy. Results : The enhancement of surface dose in the TLD with metal plate was clearly detected. The TLD chips with a Gold plate was found to larger response by a factor of 1.83 in 10 MV photon beam with respect to normal chip. The sensitivity of TLD loaded with Tin was less than that for normal TLD and TLD loaded with Gold. The relative sensitivity of TLD loaded with metal has little energy dependence. Conclusion : The good stability and linearity with respect to monitor units of TLD loaded with metal were demonstrated by relative measurements in high energy Photon ($6\~15$ MV) beams. The TLD laminated with metals embedded system in solid water phantom is a suitable detector for relative dose measurements in a small beam size and surface dose.

  • PDF

Evaluation of Absorbed Dose according to the Use of Bolus in Opposite Breast during Radiation Therapy of Breast Cancer using VMAT (VMAT를 이용한 유방암 방사선치료 시 반대편 유방의 Bolus 사용에 따른 흡수선량 평가)

  • Kim, Jong-Bo;Shin, Sang-Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.763-768
    • /
    • 2018
  • Although the development of radiation therapy techniques has made the treatment more precise, exposure by radiation is unavoidable beyond the treatment site. In this study, we wanted to evaluate the absorbed dose according to the thickness of the bolus on the opposite side of the treatment in radiation treatment for breast cancer and to analyze the effect of dose reduction. An experiment was conducted on Rando phantom using VMAT treatment methods. Five points of A, B, C, D, and E were selected for the breast opposite the treatment, and when the dosimeters of 5, 10, 15, and 20 mm were used. The highest absorbed dose at point D closest to the treatment point was measured and lowest at point B furthest from the treatment point. The mean absorbed dose was 8.61 cGy When the bolus is not used and 8.10, 7.94, 8.06, and 8.10 cGy Depending on the thickness of the bolus. In this study, bolus was intended to be used to analyze the dose-reducing effects of breasts on the other side of the treatment. The results of the study showed the effect of dose reduction and the appropriate bolus thickness should be set up to reduce the dose in normal tissues.

CHEMOPREVENTION OF COLON CANCER BY THE KOREAN FOOD STUFFS COMPONENTS

  • Kim, Dae-Joong;Shin, Dong-Hwan;Ahn, Byeong-Woo;Jang, Dong-Deuk;Hiroyuki Tsuda;Shoji Fukushima
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.05b
    • /
    • pp.106.2-132
    • /
    • 2002
  • 형질전환 (유전자 결핍; Knockout) Min 마우스를 이용하여 대장암 발생에서 배추, 양배추 주성분인 indole-3-carbinol (I3C)의 대장암 예방효과를 규명하고자 하였다. 실험동물로는 C57BL/6J-Apc$^{min/+}$(Min 마우스)계의 5내지 6주령의 수컷 이형접합체 형질전환 마우스 70마리와 C57BL/6J계의 동일 산자, 동일 주령의 수컷 wildtype 비형질전환 마우스 10kfl를 The Jackson Laboratory 사 (Bar harber, ME, USA)로부터 직접 구입하였다. C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 (Min)마우스 70마리를 각 군 20내지 25마리씩 세군으로 나누었다. Group 1에는 20마리, Group 2에는 25마리, Group 3에는 25마리를 배치하고, I3C 투여 실험군 (Group 1과 2)에는 실험시작시에 AIN-76A 분말사료에 I3C가 각각 100 및 300ppm이 함유되도록 조제하여 공급하였다. 그리고 실험군(Group 3)에는 실험시작부터 종료시까지 AIN-76A 정제고형사료(Teklad사, WI, USA)를 자유로이 급이하였다. 각군간의 체중, 사료 및 음수소비량을 매 2주마다 측정하였고, 10주간 (16주령)의 실험종료시에는 최종체중과 간장, 신장, 비장 등의 장기무게를 측정하여 상대장기 무게비를 산출하였다. 대조군으로서 C57BL/6J계의 동일 산자, 동일 주령의 수컷 wildtype 비형질전환 마우스 10마리는 같은 조건의 사육실에서 AIN-76A 정제고형사료를 33주간 자유로이 급이하였다. 실험동물은 부검전에 하룻밤 동안 절식하고 이산화탄소 흡입 마취하에서 흉대동맥을 절단하여 방혈하고 각 장기(심장, 폐, 위)를 적출하여 생리심염수에 넣어 장기무게를 측정하고 포르말린에 고정하였다. 소장과 대장의 검사를 위하여 위의 식도부위와 직장을 실로 결찰하여 적출하고 생리심염수를 주입하여 팽창시켜, 십이지장, 공장, 및 회장, 그리고 대장으로 나누어 여과지에 펼친 후 포르말린에 고정하였다. 소장과 대장은 육안 및 자동 영상분석길ㄹ 이용한 분석이 끝난 후에 각 부위별로 4-6개의 절편을 작제하여 포르말린에 재고정하고, 통상적인 조직처리과정, 파리핀 포매 및 3-4$\mu$m 두께의 조직절편을 제작하여 H&E 염색을 실시하여 현미경으로 검경하였다. 약 1주일간의 포르말린 고정이 끝난 소장 및 대장을 부위별, 별 종양개수 및 분포를 자동영상분석기(Kontron Co. Ltd., Germany)로 분석하였다. 체의 변화, 장기무게, 사료소비량 및 마리당 종양의 개수에 대한 통계학적 유의성 검증을 위하여 Duncan's t-test로 통계처리 하였고, 종양 발생빈도에 대하여는 Likelihood ration Chi-square test로 유의성을 검증하였다. C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스에 AIN-76A 정제사료만을 투여한 대조군의 대장선종의 발생률은 84%(Group 3; 21/25례)로써 I3C 100ppm 및 300ppm을 투여한 경우에 있어서는 각군 모두 60%(Group 1; 12/20 례, Group 2; 15/25 례)로 감소하는 경향을 나타내었다. 대장선종의 마리당 발생개수에 있어서는 C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스에 AIN-76A 정제사료만을 투여한 대조군은 1.40$\pm$0.24(100%)에 비하여 I3C 저농도 투여 실험군(Group 1; 0.85$\pm$0.23; 61%, P<0.01), 그리고 I3C 고농도 투여 실험군(Group 2 ; 1.32$\pm$0.29 ; 94%)의 순으로 감소하였다. 선종의 크기별 종양의 발생개수의 분포에 있어서 I3C 저농도 투여 실험군에 있어서는 선종의 크기가 3mm이하의 수가 현저하게 감소하였다. C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스에 AIN-76A 정제사료만을 투여한 대조군의 부위별 소장선종의 발생수는 십이지장부위를 제외하고 각 군에서 유의한 변화는 관찰되지 않았다. 십이지장 종양의 발생개수에서만 I3C 저농도 투여 실험군(Group 1 ; 3.11$\pm$0.85)이 대조군 (Group 3: 1.48$\pm$0.35) 및 I3C 고농도 투여 실험군(Group 2: 1.56$\pm$0.47)에 비하여 유의성 있게 증가하였다. (P<0.05). 따라서 I3C은 소장에서는 암예방 효과가 뚜렷하지 않으나, 대장에 대한 암에방 효과가 있을 것으로 생각된다. 소장 및 대장을 제외한 간장, 신장, 비장, 심장, 폐 그리고 위 등의 기타 장기에서의 조직병리학적 변화는 관찰되지 않았다. 소장 및 대장의 종양은 선종(polyps)으로 관찰되었다. 지난 10여년간 형질전환 및 유전자 결핍 실험동물의 종류가 기하 급수적으로 증가하여 이용되고 있다. 가족성 대장 선종성 용종증(FAP)의 대표적인 모델로 이용되고 있는 C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스를 사용하여 배추나 양배추의 주요성분인 Indole-3-carbinol(I3C)의 대장암 예방효과가 있는지를 검색하여 본 결과 AIN-76A정제사료만을 투여한 대조군의 대장선종의 발생률 84%에 비하여 I3C 100 및 300ppm을 투여한 실험군에 있어서 각군 모두 60%로서 감소하는 경향을 나타내었으며, 대장선종의 마리당 발생개수에 있어서는 대조군의 1.40$\pm$1.041를 100%로 환산하였을 경우 I3C 저농도 및 고농도 투여 실험군에서는 각각 약 61%와 94%를 나타내여 감소하였다. 특히 대장선종의 크기별 분포에 있어서 선종의 크기가 3mm이하의 수가 현저하게 감소하였다. 따라서 저농도 I3C의 투여는 실험적 유전성 가족성 대장 선종성 용종증 모델에 있어서 어느정도 암 예방효과가 있는 것으로 생각된다. 그러나 소장 선종의 발생에는 별 영향이 없는 것으로 생각된다. 그러나 본 실험에 사용된 C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스는 실험개시 시점이 7내지 8주령이 경과하여 이미 태생기부터 소장 및 대장의 선종 발생이 진행되어 온 것을 감안하고 특히 비스테로이드계 항염증 소염제(NSAIDS)와 같은 강력한 COX-2억제제가 아님을 고려하면, 상당한 선종의 발생을 억제할 수 있는 가능성이 매우 높다고 생각한다. 또한 이제까지 배추나 양배추 성분의 복합성분들에 대한 실험적 대장암 모델에서의 촉진효과 등에 대한 보고들이 있어 온 점을 고려할 때 위암(Kim 등, 1994) 간암(Kim 등, 1994), 유방암(Grubbs, 등, 1995; Bradlow 등, 1995)에 대한 예방효과가 있을 것으로 생각된다. 앞으로 이러한 종양조직내에서의 COX-2 및 iNOS mRNA와 단백질의 발현정도를 분자병리학적으로 연구중에 있으며, 향후 십자화과식물 성분인 indole-3-carbinol이 마우스뿐 만 아니라 랫드의 화학발암물질에 의한 대장종양에 대한 억제효과 있는지 연구 필요가 있다. Min 마우스와 같은 형질 전환(유전자결핍;knockout) 실험동물을 이용한 새로운 중기 발암성 시험범의 확립을 통한 각종 환경 유해물질의 발암성 유무 및 COX-2 억제작용이 있는 식품인자의 암예방 후보물질을 체계적으로 검색하는데 유용하게 활용될 수 있을 것으로 생각한다.

  • PDF

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

Analysis of Mediatinal Lymph Nodes with Internal Low Density on Contrast Enhanced CT Scan (조영종강 전산화단층촬영상 내부 저밀도 음영을 보이는 종격동 림프절의 분석)

  • Ryu, Young-Hoon;Choe, Kyu-Ok;Hong, Yong-Kook;Kim, Sung-Kyu;Chang, Joon;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.264-279
    • /
    • 1997
  • Background : To analyze the morphologic characteristics of low density lymph node in etiologic differentiation of lymphadenopathy, emphasizing the different features between tuberculosis and lung cancer, on contrast enhanced CT scan. Method : A total of 64 patients who showed low density lymph nodes on chest CT scan were analyzed. Primary causes were tuberculosis (n=28), lung cancer (n=27), malignant lymphoma (n=5) and metastasis from extrathoracic malignancies (n=4). CT scan was performed with 10mm slice thickness and 7 characteristic features were evaluated : location, size, presence or absence of the nonnecrotic lymph node, calcification, perinodal fat obliteration, thickness and evenness of the enhancing rim. Results : In patients with tuberculous lymphadenopathy, lymph nodes with uneven (68.0%) and thick (62.1%) enhancing rim were more common than lung cancer (p<0.05). Low density lymph nodes with less than 1 cm in size were found only in tuberculous lymphadenopathy(n=10). In 48.2% of patients with lung cancer, more than 1 nonnecrotic enlarged lymph node were coexisted, whereas 21.4% in patients with tuberculous lymphadenopathy(p=0.06). However, the size, location and calcification were not statistically significant between tuberculous lymphadenopathy and lung cancer. Conclusion : Tuberculous lymphadenopathy is strongly suggested when enhancing rim of enlarged lymph nodes is uneven and thick, when the coexisting nonnecrotic lymph nodes are few in number and when central low density is encountered in normal sized lymph nodes.

  • PDF